background image

Certified to comply with ANSI A112.18.1

Installation

Instructions

Centerset Lavatory Faucet with

the Speed Connect™ Drain 

Adjustable Wrench

 Screwdriver

Channel Locks

Recommended tools

Tubing Cutter

1

INSTALL FAUCET

SINK OR

MOUNTING

SURFACE

POP-UP

CABLE

PUTTY

Turn off hot and cold water supplies before beginning.
Apply a bead of PUTTY along the edge of the

underside of the BODY (1). Insert FAUCET (1)

and CABLE CONNECTOR (2) through mounting

holes of Sink or mounting surface. 

Fig.

 

A.

Assemble LOCKNUTS (3) onto SHANKS (4) from

under side of Sink. Hand tighten firmly. 

Fig.

 

B.

 

2

2

4

3

3

4

Turn off hot and cold water

supplies before beginning.

CAUTION

(HAND TIGHTEN)

Center -Set Lavatory Faucet

with Pop-up Drain

Fig.

 

A.

Fig.

 

B.

Speed Connect™ Drain

Troubleshooting Guide

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled

as “Cam”  and “Cam Cap” in the illustration. 

Fig.

 

B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. 

Fig.

 

D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. 

Fig.

 

E.

The Stopper can now be removed by lifting it out of the Drain. 

Fig.

 

F.

CAM

CAM CAP

CABLE ADJUSTMENT PROCEDURE

If sink does not hold water even though Stopper is in the “down” position:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

     • Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:

     • Follow STOPPER INSTALLATION PROCEDURE for “Unlocked” mode. 

                                                                          

Fig.

 

B.

Fig.

 

A.

REMOVE

CAM

Fig.

 

E.

Fig.

 

F.

Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as

“Cam” in the illustration. 

Fig.

 

B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the

Stopper should be in the UP position. 

Fig.

 

B, C.

 

Push DOWN on the Lift-Knob to make sure it is fully down. 

Fig.

 

C.

Re-attach the Cable to the Drain Body Connection (2) by threading the Cable Connector (1) clockwise onto the

Drain Body Connection (2) and hand-tighten. 

Fig.

 

A.

STOPPER REMOVAL PROCEDURE

STOPPER INSTALLATION PROCEDURE

Locked Mode: 

Look at the Plastic Loop at the bottom of the Stopper and notice

that the Loop is on one side of the Stopper. 

Fig.

 

G.

To install the stopper in 

“Locked”

 mode, insert the Stopper into

the Drain so that the Plastic Loop is facing toward the 

rear

 of the

Sink and the American Standard logo is facing 

front

. Rotate

Stopper slightly if necessary so that the Stopper slides all the

way down.

Fig.

 

G.

Re-install the Cam into the Drain, rotating the Cam if necessary

to make sure it is fully inserted. 

Fig.

 

J.

Re-install the Cam Cap, making sure the guide teeth are facing

outward. If the Cam Cap does not “snap” into place, then rotate

the Cam to make sure it is fully inserted. 

Fig.

 

K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

Troubling Shooting Guide to complete installation. Stopper will be

in 

“Locked”

 mode and not be removable.

Unlocked Mode: 

Look at the Plastic Loop at the bottom of the Stopper and notice

that the Loop is on one side of the Stopper. 

Fig.

 

H.

To install the stopper in 

“Unlocked”

 mode, insert the Stopper into

the Drain so that the Plastic Loop is facing toward the 

front

 of the

Sink and the American Standard logo is facing 

rear

. Rotate Stopper

slightly if necessary so that the Stopper slides all the way down.

Fig.

 

H.

Re-install the Cam into the Drain, rotating the Cam if necessary

to make sure it is fully inserted. 

Fig.

 

J.

Re-install the Cam Cap, making sure the guide teeth are facing

outward. If the Cam Cap does not “snap” into place, then rotate

the Cam to make sure it is fully inserted. 

Fig.

 

K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

“Troublingshooting Guide” to complete installation. Stopper will be

in 

“Unlocked”

 mode and removable

.

Fig.

 

J.

Fig.

 

K.

INSTALL

CAM CAP

CAM

INSTALL CAM

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be

removed) or “Unlock” Mode (Stopper is removable).

Unlocked Mode

LOOP TOWARD

FRONT OF SINK

180˚

DRAIN

Fig.

 

H.

Locked Mode

(Vandal Proof)

LOGO

DRAIN

Fig.

 

G.

LOOP TOWARD

REAR OF SINK

2

1

RE-ATTACH

DISCONNECT

Fig.

 

D.

REMOVE

CAM CAP

065800-0070A

MOUNTING NUT

024220-0070A

SUPPLY NUT

Fig.

 

C.

STOPPER

1

DOWN

M961732-YYY0A

LIFT ROD

072574-0070A

EXTENSION ROD

066116-YYY0A

DRAIN STOPPER

M961711-0070A

TAILPIECE INSERT

070847-0070A

CLIP

066118-0070A

PIVOT ROD KIT

M953450-YYY0A

COMPLETE

DRAIN ASSEMBLY

070532-0040A

TAILPIECE

066117-YYY0A

2" FLANGE KIT

POP-UP DRAIN ASSEMBLY

BEFORE 01/07

1

5

6

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1-800 442-1902

Weekdays 8:00 a.m. to 6:00 p.m. EST

IN CANADA  1-800-387-0369   (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

Product names listed herein are trademarks of American Standard Inc.

© American Standard Inc. 2004

IN MEXICO  01-800-839-12-00

2555.201

2555.201

MODEL NUMBER

994053-0070A

VALVE

A918555-0070A

HANDLE SCREW

M962537-YYY0A

POP-UP ROD

M916807-YYYOA

LEVER HANDLE

M962105-YYYOA

HANDLE BASE KIT

M918024-0070A

ADAPTER

066070-YYY0A

AERATOR

TOWNSQUARE

TOWNSQUARE

CHROME 

 

002

POLISHED BRASS 

 

099

SATIN NICKEL               295

Replace the "YYY" with

appropriate finish code

M907024-YYY0A

INDEX BUTTON (HOT & COLD)

COMPRESSION

NUT

3/8” COMPRESSION

CONNECTION

COUPLING

NUT

FLEXIBLE

SUPPLIES

3/8 O.D.

BULL-NOSE

RISERS

Operate LIFT KNOB (1) to verify that STOPPER (2) opens and

closes.

Note: If STOPPER (2) does not open and close properly then refer

to the “troubleshooting section” of these instructions.

CHECK OPERATION OF POP-UP

8

1/2" PIPE

THREAD

2

Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE

SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).

Use adjustable wrench to tighten connections. Do not over tighten.

Be careful not to kink copper supply when bending. Use tubing

cutter to cut to proper length.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to

waste outlet.

MAKE WATER SUPPLY AND WASTE CONNECTIONS

9

FERRULE

1

2

3

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE

PURCHASED SEPARATELY.

HOT

COLD

Thread CABLE CONNECTOR (1) clockwise

onto DRAIN BODY CONNECTION (2) and

hand tighten. 

Fig.

 

A.

Your new POP-UP DRAIN installation is

now complete. 

Fig.

 

B.

Note: 

Tailpeice on pop-up drain is 1-1/4” O.D.

Fig.

 

B.

Fig.

 

A.

ATTACH CABLE CONNECTOR

7

2

1

Fig.

 

B.

1-1/4” O.D.

1

7

3

Thread FLANGE (1) counter-clockwise and remove

FLANGE (1) and FOAM GASKET (2) from drain

body. 

Fig.

 

A.

Thread LOCKNUT (3) clock-wise to bottom of

drain body. Push GASKET (4) down against

LOCKNUT (3). 

Fig.

 

B.

POP-UP DRAIN

Tighten TAILPIECE (4) on DRAIN BODY before

installing DRAIN BODY. 

Fig.

 

B.

6

2

4

3

2

TIGHTEN LOCKNUT

1

REMOVE FLANGE

Remove CLEAR PLASTIC COVER (1).

Remove CARDBOARD SPACER (2) from under

DRAIN POP-UP (3).

2

2

3

3

1

1

Tighten LOCKNUT (1) firmly with Adjustable

Wrench or Channel Locks.

INSTALL DRAIN FROM

BELOW FIXTURE

5

From under side of SINK

install DRAIN BODY (1) up

through drain outlet.

Note: No plumber’s putty

or caulk is required.

The CABLE ATTACHMENT

POINT (2) must face towards

the rear of the SINK.

Install FOAM GASKET (3) and

FLANGE (4) onto drain body

from above SINK and tighten

FLANGE (4) firmly.

4

Fig.

 

A.

Fig.

 

B.

Fig.

 

A.

Fig.

 

B.

2

DRAIN

OUTLET 

1

3

4

POP-UP KNOB (1) must be fully down. 

Fig.

 

B.

  

FLANGE GASKET AND POP-UP KNOB

WHITE FOAM

GASKET

NOT VISIBLE

DRAIN

FLANGE

Fig.

 

A.

Fig.

 

B.

Check DRAIN FLANGE in SINK to ensure that

WHITE FOAM GASKET (3) is fully compressed

and not visible. 

Fig.

 

A.

DRAIN

BODY

4

REAR OF SINK

1

DOWN

2

1

4

1

SERVICE

10

TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER

SUPPLIES (2) and check all connections for leaks.

Remove AERATOR (3).

Operate both HANDLES (1) to flush water lines thoroughly.

Replace AERATOR (3).

5

2

CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB (4) and fill lavatory with water.

Check that DRAIN STOPPER (5) makes a good seal

and retains water in SINK. If DRAIN STOPPER (5)

does not seal properly, please refer to Troubleshooting

section in these instructions.

Release POP-UP KNOB (4) down and check all drain

connections and "P" trap for leaks.     Tighten

if necessary.

12

11

“P” TRAP

WASTE

OUTLET

3

If spout drips, operate handles several times

from OFF to ON position. Do not force - handles

turn only 90˚.

To change direction of handle rotation, proceed as follows:

T

urn valve to OFF position.

Remove IINDEX (1) and HANDLE SCREW (2).

Pull HANDLE (3)  and ESCUTCHEON (4) off.

Remove ADAPTER (5) and SPRING CLIP (6).

Lift STOP WASHER (7), turn 90˚ and replace.

Replace SPRING CLIP (6).

Replace ADAPTER (5), ESCUTCHEON (4)

HANDLE (3), SCREW (2), and INDEX (1).

2

1

3

4

M 9 6 8 7 8 6   R e v . 1 . 3

M 9 6 8 7 8 6   R e v . 1 . 3

M 9 6 8 7 8 6   R e v . 1 . 3

M 9 6 8 7 8 6   R e v . 1 . 3

M 9 6 8 7 8 6   R e v . 1 . 3

M 9 6 8 7 8 6   R e v . 1 . 3

M 9 6 8 7 8 6   R e v . 1 . 3

90˚ 

6

7

8

5

4

Remove AERATOR (8) and rinse clean if water flow

becomes distorted.

LOGO

Congratulations on purchasing your American Standard

faucet with Speed Connect drain, a feature found only on

American Standard faucets.

*Your new American Standard faucet is designed to work only with the Speed Connect drain.

To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.

Speed Connect™ Drain*

•  Fewer parts, installs in less time

•  Never needs adjustment

•  Guaranteed to seal properly the first time, every time.

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER.DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.

CARE INSTRUCTIONS:

M962552-0070A

CAM ASSEMBLY

M952430-0070A

CABLE ASSEMBLY

M952425-YYY0A

 DRAIN ASSEMBLY

M962544-YYY0A

STOPPER

ASSEMBLY

M962457-YYY0A

FLANGE

ASSEMBLY

M962458-0070A

DRAIN MOUNTING KIT

A919661-0020A  

TAILPIECE

M922872-0070A

CAM SEAT INSERT

M913207-0070A

TAILPIECE INSERT

M919660-0020A

6” TAILPIECE

(NOT INCLUDED

WITH FAUCET)

Содержание Townsquare 2555.201

Страница 1: ...emble LOCKNUTS 3 onto SHANKS 4 from under side of Sink Hand tighten firmly Fig B 2 2 4 3 3 4 Turn off hot and cold water supplies before beginning CAUTION HAND TIGHTEN Fig A Fig B 1 2555 201 TOWNSQUARE M968786 Rev 1 3 Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Your new American Standard faucet is designed t...

Страница 2: ...ch or Channel Locks INSTALL DRAIN FROM BELOW FIXTURE 5 From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 mustfacetowards the rear of the SINK Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly 4 Fig A Fig B Fig A Fig B 2 DRAIN OUTLET 1 3 4 POP UP KNOB 1 must be f...

Страница 3: ... Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect 1 1 4 O D tailpiece on POP UP DRAIN to waste outlet MAKE WATER SUPPLY AND WASTE CONNECTIONS 9 FERRULE 1 2 3 NOTE FLEXIBLE SUPPLIES OR BULL NOSE RISERS MUST BE PURCHASED SEPARATELY HOT COLD Thread CABLE CONNECTOR 1 clockwise onto DRAIN...

Страница 4: ...ecessary 12 11 P TRAP WASTE OUTLET 3 If spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 To change direction of handle rotation proceed as follows Turn valve to OFF position Remove IINDEX 1 and HANDLE SCREW 2 Pull HANDLE 3 and ESCUTCHEON 4 off Remove ADAPTER 5 and SPRING CLIP 6 Lift STOP WASHER 7 turn 90 and replace Replace SPRING CLIP 6 Replace A...

Страница 5: ...STMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig B Fig A REMOVE CAM Fig E Fig F Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body wher...

Страница 6: ... Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain...

Отзывы: