Pull INDEX CAP, unscrew HANDLE SCREW and pull HANDLE off valve stem.

Remove two SCREWS holding ESCUTCHEON and remove ESCUTCHEON. Remove COVER by pulling straight out.

Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve, if present.

TO GAIN ACCESS TO VALVE FOR SERVICING

7

Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and
pull out PRESSURE BALANCING (5) unit.

Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove
CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).

Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws.

Turn on water supply and see above for installing TRIM and HANDLE.

VALVE LEAKS WHEN SHUT OFF

BACK TO BACK INSTALLATION

BACK TO BACK INSTALLATION

ROTATE 180

˚

Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7) and clean valve thoroughly.

Examine balancing unit and check condition of O-ring on end of piston.  Piston should move back and forth.  Order Repair
Part M952100-0070A if balancing unit is defective.

Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.

Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up and the
large outlet port faces down.

Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting. Top flange should
butt up against top of casting.

Reassemble FIXATION RING (4) and CARTRIDGE (1).

UNABLE TO MAINTAIN CONSTANT TEMPERATURE

1

2

9

5

5

7

8

6

4

3

INLETS

LARGE OUTLET

5

INSTALL HANDLE

Install HANDLE BUSHING (1) onto CAP (2). 

Find correct position of HANDLE (3) and push HANDLE (3)
onto VALVE STEM (4).

Install HANDLE SCREW (5) and push in INDEX CAP (6).

Check proper operation of HANDLE.

Screw on DIVERTER KNOB (7).

5

6

3

1

2

4

7

EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with 
clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.