10
3
5
5/16'' MIN.
MOUNTING SURFACE
11
11
10
11
1
3
Push TUBING (4) ends into VALVE (5) side outlets. Insert VALVES (5)
into mounting holes from underside of ledge.
Install LOCKNUTS (1) and RUBBER WASHERS (3) onto valve shanks.
Place RUBBER RING (11) into DECK ADAPTERS (10) and thread onto
valves until snug against internal stop.
Tighten LOCKNUT (1) to secure VALVE (5) position.
Slide FERRULE (13) and COUPLING NUT (14) to outlet of VALVE (5) and tighten
COUPLING NUT (14) firmly.
Connect HOT water supply to inlet of left VALVE and COLD water supply to inlet of
right VALVE using appropriate connector.
VALVE ASSEMBLY
HOT
COLD
13
5
14
8
7
9
9a
6
14
13
4
5
10
MOUNTING
LEDGE
DECK ADAPTER
4
INSTALL HANDLES
1
2
3
4
5
6
7
10
Figure B
Figure A
Figure D
Figure C
4
5
6
10
5
10
8
Turn VALVE to OFF position.
Figure A: Install STEM ADAPTERS (7) onto VALVE STEMS (8).
Figure B: With colored side up, place FRICTION RING (6) over DECK ADAPTER (10). Loosely screw FRICTION NUT (5)
onto DECK ADAPTER (10). Do not tighten. Align flats on FRICTION NUT (5) with RIBS (9) in HANDLE BASE (4).
Figure C: Screw HANDLE BASE (4) with FRICTION NUT (5) onto DECK ADAPTER (10) until snug against mounting
surface and aligned properly.
Figure D: Install LEVER HANDLE (3) onto HANDLE ADAPTER (7) and align. Check alignment, if not satisfactory remove
and align. Insert HANDLE SCREW (2) and tighten. Press in INDEX BUTTON (1).
9
4
FLATS
ALIGNED
. 3 F W
FOR FITTING
LESS SPRAY
Press TEE (6) onto SPOUT SHANK (7) making certain that the O-RING (8) is
properly seated on SHANK (7). Push COUPLING (9 or 9a) into TEE (6) and
attach to SPOUT SHANK (7) and tighten.
Note: For product with Hand
Shower, COUPLING (9) is tightened using a 10mm (3/8”)
Hex Wrench.