INSTALL TRIM
1
Remove PLASTER GUARD (1).
Push CAP (2) on valve, place ESCUTCHEON HOLDER
(3) and attach with LONG SCREWS (4).
Place ESCUTCHEON (5) and attach with SHORT
SCREWS (6).
Choose one of the DECORATIVE RINGS (7)
and push it onto CAP (2).
Push HANDLE (11) onto cartridge stem
and tighten SET SCREW (12) from below.
NOTE: Lift handle to access SET
SCREW (12)
Install SHOWER ARM (8), SHOWER HEAD (9)
and DIVERTER SPOUT (10).
Check proper operation of HANDLE (11)
and DIVERTER SPOUT (10).
10
2
3
5
6
7
11
12
4
9
8
6
1
M 9 6 8 3 8 8 R e v. 1 . 1
3
EverClean™ Finish Care Instructions
American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with
clean water may also be used, if desired. No additional cleaning products are required.
DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.
2
ADJUST HOT LIMIT STOP
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP
reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust
the setting on the HOT LIMIT SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B" to
adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
HOT LIMIT SAFETY STOP ADJUSTMENT
PRY RED RING FORWARD AND ROTATE
COUNTER-CLOCKWISE ONE CLICK
PRY RED RING FORWARD AND ROTATE CLOCKWISE
"A"
ADJUSTMENT WHEN WATER IS TOO HOT
"A"
"B"
"B"
ADJUSTMENT WHEN WATER IS TOO COLD
"RED RING"- HOT LIMIT SAFETY STOP
TEMPERATURE SETTING NUMBERS
0
1
2
3
4
5
6
1