2
2
1
1
9
TEST INSTALLED FITTING
With HANDLES
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Remove AERATOR
(3)
.
Operate both HANDLES
(1)
to flush water lines thoroughly.
Replace AERATOR
(3)
.
5
2
3
4
3
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB
(4)
and fill lavatory with water.
Check that DRAIN STOPPER
(5)
makes a good seal
and retains water in SINK. If DRAIN STOPPER
(5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB
(5)
down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
11
“P” TRAP
WASTE
OUTLET
4
AERATOR
(6)
may accumulate dirt causing distorted and reduced
water flow. Remove AERATOR
(6)
and rinse clean.
To change direction of handle rotation, proceed as follows:
10
SERVICE
1
6
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
4
Turn VALVE in OFF position.
Loosen HANDLE SCREW
(2)
, and pull HANDLE
(1)
off ADAPTOR
(3)
.
Turn VALVE to OFF position.
To change direction of handle
rotation, proceed as follows:
Pull ADAPTOR
(3)
off VALVE STEM
(5)
and turn 90˚ in a way that flat
in ADAPTOR
(3)
catches a different flat in on VALVE STEM
(5)
.
If spout drips, operate HANDLES
(1)
several times from OFF to ON
position. Do not force-handles turn only 90˚.
Reinstall ADAPTER SCREW
(3)
, HANDLE
(1)
and HANDLE SCREW
(2)
.
Remove ADAPTOR SCREW
(4)
.
5
FLAT
90˚
M 9 6 8 8 0 6 R E V 1 . 3
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS: