background image

2

2

1

1

9

TEST INSTALLED FITTING

With HANDLES 

(1)

 in OFF position, turn on WATER

SUPPLIES 

(2)

 and check all connections for leaks.

Remove AERATOR 

(3)

.

Operate both HANDLES 

(1)

 to flush water lines thoroughly.

Replace AERATOR 

(3)

.

5

2

3

4

3

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB 

(4)

 and fill lavatory with water.

Check that DRAIN STOPPER 

(5)

 makes a good seal

and retains water in SINK. If DRAIN STOPPER 

(5)

does not seal properly, please refer to Troubleshooting
section in these instructions.

Release POP-UP KNOB 

(5)

 down and check all drain

connections and "P" trap for leaks.      Tighten
if necessary.

11

“P” TRAP

WASTE

OUTLET

4

AERATOR 

(6)

 may accumulate dirt causing distorted and reduced

water flow.  Remove AERATOR 

(6)

 and rinse clean.  

To change direction of handle rotation, proceed as follows:

10

SERVICE

1

6

If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.

4

Turn VALVE in OFF position.

Loosen HANDLE SCREW 

(2)

, and pull HANDLE 

(1)

 off ADAPTOR 

(3)

.

Turn VALVE to OFF position.

To change direction of handle
rotation, proceed as follows:

Pull ADAPTOR 

(3)

 off VALVE STEM 

(5)

 and turn 90˚ in a way that flat

in ADAPTOR 

(3)

 catches a different flat in on VALVE STEM 

(5)

.

If spout drips, operate HANDLES 

(1)

 several times from OFF to ON

position. Do not force-handles turn only 90˚.

Reinstall ADAPTER SCREW 

(3)

, HANDLE 

(1)

 and HANDLE SCREW 

(2)

.

Remove ADAPTOR SCREW 

(4)

.

5

FLAT

90˚ 

M 9 6 8 8 0 6   R E V   1 . 3

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.

CARE INSTRUCTIONS:

Содержание Symphony 4504

Страница 1: ...FAUCET SINK OR MOUNTING SURFACE POP UP CABLE Turn off hot and cold water supplies before beginning Insert FAUCET 1 and CABLE CONNECTOR 2 through mounting holes of Sink or mounting surface Fig A Assemb...

Страница 2: ...COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Fig A 2 REAR OF SINK 4 5 6 3 1 SINK DRAIN HOLE FLAT SIDE OF GASKET MUST FACE DOWN 1 2 Fig A 2 1 FLAT SIDE OF GRAY LOCKNUT MUST FACE UP INSTA...

Страница 3: ...hen refer to the troubleshooting section of these instructions CHECK OPERATION OF POP UP 7 1 1 4 O D Fig B 1 2 PIPE THREAD Connect water supply to FAUCET 1 with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 O D...

Страница 4: ...clean To change direction of handle rotation proceed as follows 10 SERVICE 1 6 If spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 4 Turn VALVE in O...

Страница 5: ...ly Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follo...

Страница 6: ...Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is fac...

Страница 7: ...ls METAL OR PLASTIC TWO PIECE DRAIN BODY METAL DRAIN BODY WITH PLASTIC TAILPIECE PLASTIC DRAIN BODY WITH PLASTIC TAILPIECE UNTHREAD METAL FLANGE STOPPER WHEN DRAIN IS REMOVED FROM ABOVE SINK WHEN DRAI...

Отзывы: