background image

STRATFORD™ 5-1/2'

WHIRLPOOL AND BATHING POOL

AMERICAST® BRAND ENGINEERED MATERIAL

© 2005 American Standard Inc.

1676mm

(66)

813mm

(32)

235mm

(9-1/4)

406mm

(16)

OUTLINE OF 1638 X 775mm
(64-1/2 X 30-1/2) CUTOUT

19mm
(3/4)

C/L OF

SUPPLIES

FINISHED
WALL

32mm
(1-1/4)

C/L OF DRAIN
       OUTLET

229 X 305mm
(9 X 12) FLOOR CUTOUT

508mm

(20)

476mm

(18-3/4)

MIN.

32mm 
(1-1/4)

1-1/2 N.P.T. THREADS

1-1/2 O.D. TAILPIECE

70mm

(2-3/4)

117mm (4-5/8)

SUPPORT 
STRINGER

305mm

(12)

102mm
(4)

1651-1982mm

(65-78) 

OPTIONAL

70mm

(2-3/4)

FINISHED 
WALL

C/L OF

SHOWER ARM

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
OVERFLOW

SEE FITTING SPECS

FOR DIMENSION

203mm

(8)

1676mm

(66)

813mm

(32)

PROVIDE ACCESS

TO PUMP FOR

SERVICING

ON ALL 

INSTALLATIONS

235mm

(9-1/4)

406mm

(16)

OUTLINE OF 1638 X 775mm
(64-1/2 X 30-1/2) CUTOUT

19mm
(3/4)

C/L OF 1/2
SUPPLIES

AS  REQUIRED

FINISHED
WALL

PUMP

ON/OFF

SWITCH

32mm
(1-1/4)

C/L OF DRAIN
       OUTLET

229 X 305mm
(9 X 12) FLOOR CUTOUT

508mm

(20)

476mm

(18-3/4)

MIN.

32mm 
(1-1/4)

1-1/2 N.P.T. THREADS

1-1/2 O.D. TAILPIECE

70mm

(2-3/4)

117mm (4-5/8)

SUPPORT 
STRINGER

324mm

(12-3/4)

102mm
(4)

711mm

(28)

32mm (1-1/4) DIA. HOLE 
1/2 N.P.T. SHOWER

44mm (1-3/4) DIA. HOLES
FOR CONTROL VALVES

32mm (1-1/4) DIA. HOLE FOR 
1/2 N.P.T. SPOUT

203mm
 (8)

1651-1982mm

(65-78) 

OPTIONAL

1/2 SUPPLIES

AS REQ'D

C/L OF SHOWER

CURTAIN ROD

1930mm (76)

OPTIONAL

TO FLOOR

70mm

(2-3/4)

FINISHED 
WALL

C/L OF
OVERFLOW

76mm

(3)

SAFE-T-HEATER

REMOVABLE BLANK

NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER,
ISLAND, OR PENINSULA TYPE INSTALLATION. SUPPORT OF BATH BY RIM,
SUMP SUPPORT NOT REQUIRED. SUPPORT AND ENCLOSING MATERIAL BY 
OTHERS
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH
WHIRLPOOL/BATH FOR ADDITIONAL INFORMATION.
OPTIONAL 3-WALL TILING BEAD KIT AVAILABLE AND MUST BE ORDERED
SEPARATELY.
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
SHOWN WITH POP-UP C.D. & O.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
CONCEALED PIPING NOT INCLUDED.

GENERAL SPECIFICATIONS FOR 2470 WHIRLPOOL

WHIRLPOOL ELECTRICAL SPECIFICATIONS

SYSTEM I PUMP

1.6 HP, 9.7 AMPS,120V.

66 x 32 x 20 In. (1676 x 813 x 508mm)

201 Lbs. (90 Kg.)

701 Lbs. (315 Kg.)

60 Gal. (227 L)
40 Gal. (152 L)

42 x 19 In. (1067 x 483mm)
60 x 27 In. (1524 x 686mm)

14 In. (356mm)

55 Lbs./Sq.Ft. (223 Kgs./Sq.m)

13.9
33.7

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

GENERAL SPECIFICATIONS FOR 2470 BATHING POOL

66 x 32 x 20 In. (1676 x 813 x 508mm)

174 Lbs. (78 Kg.)

674 Lbs. (303 Kg.)

60 Gal. (227 L)

42 x 19 In. (1067 x 483mm)
60 x 27 In. (1524 x 686mm)

14 In. (356mm)

48 Lbs./Sq.Ft. (206 Kgs./Sq.m)

13.9
33.7

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

Dimensions of fixtures are nominal and may vary within the range of toler-
ances established by ANSI Standard A112.19.4
These measurements are subject to change or cancellation. No responsibili-
ty is assumed for use of superseded or voided leaflet.

IMPORTANT:

Отзывы: