background image

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

Fig. 5

1.

 Remove the bottom SUPPLY HOSE (1) from the 

SELECTRONIC ENCLOSURE (2). Fig. 3

2. 

Remove BOTTOM PLUG (3) from SELECTRONIC 

ENCLOSURE (2). Fig. 3

 

3. 

Remove 4 screws from MIXER ENCLOSURE 

COVER (2) and pull off COVER (2). Fig. 3b

4.

 Remove MIXING VALVE (7) from ENCLOSURE (3). 

5. 

Install MIXER ENCLOSURE (4) under SELECTRONIC 

ENCLOSURE (2) as shown in Fig. (3a). Hold the MIXER 
ENCLOSURE (4) in that location and mark the four 
mounting hole locations as shown. Fig. (3a)

NOTE: MIXER ENCLOSURE SUPPLY HOSES are 
20" long. Distance between wall valves and MIXER 
ENCLOSURE (4) must be taken into consideration.

5.

 The ENCLOSURE (4) works best if secured to a wall 

stud or cross brace within the wall, using the SCREWS 
(5) supplied. If the MIXER ENCLOSURE (4) is to be 
installed on a tile or plaster wall the ANCHORS (6) and 
SCREWS (5) should be used.

6. 

For installations on drywall or tiled walls;

 use 

ANCHORS (6) and SCREWS (5) for securing MIXER 
ENCLOSURE (4) to finished wall. Drill four 1/4" dia. 
holes a minimum of 1-3/4" deep. Insert the four 
ANCHORS (6) flush with face of the finished wall.
Align the MIXER ENCLOSURE (4) and Install the 
MOUNTING SCREWS (5). Tighten to secure MIXER 
ENCLOSURE (4) to mounting surface.

1.

 Install MIXING VALVE (1) back into ENCLOSURE.

2.

 Install FIBER SEAL WASHER (4) on MIXING 

VALVE NIPPLE (3). Hold MIXING VALVE (1) in place 
with one hand and with your other hand thread 
SWIVEL NUT (2) onto MIXING VALVE NIPPLE (3). 
Fig. 4. Use an adjustable wrench to tighten SWIVEL 
NUT (2). Fig. 4a

3.

 Replace ENCLOSURE COVER and tighten securely.

1.

 Turn off hot and cold water supplies before 

beginning.

2.

 Connect FLEXIBLE SUPPLIES (1, 2) directly to wall 

supplies. Connection on MIXER supplies are 3/8" 
compression. Connect left supply to Hot and right 
supply to Cold wall supply. Use adjustable wrench to 
tighten connections. Do not over tighten. FIG. 5

3.

 Faucet supplies measure 20" from the bottom of the 

ENCLOSURE (3) base.

Note: 

If additional supply length is required, installer 

must purchase parts separately.

Important: 

If SUPPLY HOSES (1, 2) are too long, loop 

as to avoid kinking.

    MOUNT ENCLOSURE; Fig. 3

1

    CONNECT MIXING VALVE; Fig. 4

2

    CONNECT MIXING VALVE TO
WATER SUPPLIES; Fig. 5

3

2

Fig. 4

Fig. 4a

1

2

3

4

3

1

HOT

COLD

2

2

ADJUSTABLE 

WRENCH

WALL SUPPLIES

INSTALLATION

Fig. 3

Fig. 3a

Fig. 3b

4-1/4"

(108mm)

1-3/16"

(46mm)

4

2

MOUNTING HOLES

ILLUSTRATION SHOWN

LESS MIXING VALVE

1

3

SUPPLIES

WASTE

LAVATORY RIM OR
MOUNTING SURFACE

ENCLOSURE

MOUNTING

HOLES

2

6

4

5

7

Fig. 7d

Fig. 7a

Fig. 7e

In

s

t

a

ll

a

t

io

n

 I

n

s

t

r

u

c

t

io

n

s

Отзывы: