- 3 -
7
VALVE LEAKS WHEN SHUT OFF
• Remove CARTRIDGE, see STEP 1 and STEP 2 and REVERSE process.
• Clean SEALS on the side of CARTRIDGE. Clean inside sealing surface of
VALVE BODY.
• Re-assemble CARTRIDGE. Install trim. Turn on water supply and
check for leaks.
REPLACING CARTRIDGE (FIGURE 1)
• To remove CARTRIDGE
(1)
, install split WASHER
(3)
between the ridge on the cartridge and the bonnet nut.
(only supplied with replacement cartridge). as shown.
• Proceed to unthread BONNET NUT
(2)
counter clockwise.
Note:
CARTRIDGE
(1)
should be pulling out while
unthreading BONNET NUT
(2)
.
•
Upon removal of the old Cartridge, install a new
cartridge and secure it with
BONNET NUT
(Hand tighten).
BACK TO BACK INSTALLATION (FIGURE 2, 3 & 3A)
• Remove CARTRIDGE
(1)
.
• Remove venturi tube by pushing it out. As shown in
FIGURE 3.
•
Rotate CARTRIDGE
(1)
180˚ so that the Up text is
displayed on the bottom side. As shown in
FIGURE 2.
• Reinstall the venturi tube by pushing it in.
As shown in
FIGURE 3A.
• Insert Cartridge back into the valve.
• Reassemble BONNET NUT
(2)
and hand tighten.
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
6
• Remove HANDLE (see step 3 and reverse).
• Remove ESCUTCHEON and CARTRIDGE CAP (see step 1 and reverse).
SERVICE
TO GAIN ACCESS TO VALVE FOR SERVICING
Figure 1.
1
3
2
Figure 2.
Standard
Back to Back
M965935 (8/18)
CAUTION
Turn off hot and cold water
supplies before beginning.
ROTATE 180°
Figure 3.
Figure 3A.
PUSH UP
PUSH DOWN
5
• By restricting HANDLE rotation and limiting the amount of hot water
allowed to mix with the cold, the HOT LIMIT SAFETY STOP
(1)
reduces risk of accidental scalding. To set the maximum hot water
temperature of your faucet valve, adjust the setting on the HOT LIMIT
SAFETY STOP
(1)
.
• Turn CARTRIDGE STEM
(2)
to the OFF position (coldest setting) before
making adjustment to HOT LIMIT STOP
(1)
. Pull forward and rotate
counterclockwise one number to limit hot water temperature.
Use NUMBERS
(5)
on CARTRIDGE
(4)
on HOT LIMIT STOP
(1)
for indication.
ADJUST HOT LIMIT STOP
COLDER
(Larger Numbers)
1 2 3 4 5 6 7 8 9 10
HOTTER
(Smaller Numbers)
1 2 3 4 5 6 7 8 9 10
3
4
1
5
2