background image

 17 CONGLOMKB .COM
 

 

Please contact 1-877-333-0098 for further assistance.

Specifications (continued)

EXTERNAL DIAGRAM OF RANGE HOOD

BACK

80 mm (3.12 in)

93.5 mm

(3.68 in)

10 mm (0.37 in)

250 mm (9.81 in)

757 mm (29.8 in)

20 mm

(0.75 in)

22 mm (0.87 in)

dia. hole

228 mm

(9 in)

458 mm

(18 in)

TOP

757 mm (29.8 in)

110 mm (4.31 in)

270 mm (10.62 in)

50 mm (2 in)

18 mm

(0.68 in)

28 mm

(1.25 in)

39 mm

(1.5 in)

93.5 mm

(3.68 in)

22 mm (0.87 in)

dia. hole

706 mm (27.79 in)

250 mm (9.81 in)

80 mm (3.12 in)

50 mm (2 in)

305 mm (12 in)

Содержание QR030

Страница 1: ...he benchmark of fine quality for over 100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Stainless Steel Under Cabinet Range Hood TH...

Страница 2: ...guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the...

Страница 3: ...flames with a close fitting lid cookie sheet or metal tray then turn off the burner If the flames do not go out immediately evacuate and call the fire department Never pick up a flaming pan Do not us...

Страница 4: ...rred for labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the respons...

Страница 5: ...ility knife Pencil Duct tape Adjustable wrench Phillips screwdriver Flathead screwdriver Needle nose pliers Hammer Electric drill Safety goggles Safety gloves HARDWARE INCLUDED NOTE Hardware not shown...

Страница 6: ...6 Pre Installation continued PACKAGE CONTENTS A B Part Description Quantity A Range hood including filters 1 B Damper located inside the hood 1...

Страница 7: ...be installed is recessed attach appropriately sized wood filler strips 7 on each side using wood screws 3 Screws are provided to secure the range hood to most types of cabinets but consult a qualified...

Страница 8: ...the path of the duct work using elbows keep the number of elbows to a minimum for effective performance and use no more than three 90 elbows Ensure that there is a minimum of 18 in 458 mm of straight...

Страница 9: ...nection cut a 3 2 cm 1 1 4 in hole in the wall A hole cut through wood must be sanded until smooth A hole through metal must have a grommet 8 When cutting or drilling into the wall or ceilling do not...

Страница 10: ...eave any debris inside the range hood 3 Installing the damper NOTICE Only install the damper if you are using a venting system that does not already have a damper If using the charcoal filter for duct...

Страница 11: ...hten the screws all the way leave the screw heads about 0 28 in 7 mm from the cabinet surface Lift the range hood A into position feeding the power cable and the electrical wires through the power acc...

Страница 12: ...ess the appropriate speed control switch Low Speed 2 Medium Speed 3 High Speed 4 to select the desired level of power Once a button is pressed the previous speed mode will be cancelled Press the power...

Страница 13: ...need replacing exchange with similar baffle filters with stainless steel clips Also replace baffle filters that are damaged with punctures bends or broken frames Turn off the range hood and disconnect...

Страница 14: ...not allow cleaning compounds salt solutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow deposits to remain for long periods of time on th...

Страница 15: ...on system detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after approximately 10 min Ch...

Страница 16: ...5A 320 10 High 2 x Max 25W or 35W JDR 16 GU10 twist and lock base light bulb Top venting Back venting 18 in 458 mm D Medium 9 in 228 mm H Low WIRING DIAGRAM Motor White Black Black Black Black Black B...

Страница 17: ...12 in 93 5 mm 3 68 in 10 mm 0 37 in 250 mm 9 81 in 757 mm 29 8 in 20 mm 0 75 in 22 mm 0 87 in dia hole 228 mm 9 in 458 mm 18 in TOP 757 mm 29 8 in 110 mm 4 31 in 270 mm 10 62 in 50 mm 2 in 18 mm 0 68...

Страница 18: ...ST Identify the required part s and have the part description s ready E F G H AA BB B C D A Part Description Code Quantity A Control Switch QHR106 1 B Capacitor QHR100 1 C Light QHR121 2 D Light Base...

Страница 19: ...Questions problems missing parts Before returning to the store call Customer Service 8 30 a m 5 p m EST Monday Friday 1 877 333 0098 CONGLOMKB C0M Retain this manual for future use...

Отзывы: