Unscrew the HOLDER (1) from the SHOWER ESCUTCHEON (2). Slip the
SHOWER HOSE (3) through the SHOWER ESCUTCHEON (2) and the
 HOLDER (1).

Pull out the SLEEVE GUARD (6) and HOSE (7). Unthread the SLEEVE
GUARD (6) from the HOSE END (8) connection. 

Be careful not to

allow the HOSE (7) to fall back through the SLEEVE (9).

Insert SEAL WASHER (10) into the SHOWER HOSE CONNECTOR (11).
Thread the SHOWER HOSE CONNECTOR (11) onto the HOSE END (8)
and tighten securely.

Thread the SHOWER ESCUTCHEON (2) into the SLEEVE (9) until the
SHOWER ESCUTCHEON (2) contacts the finished deck.

Loosen the SET SCREW (12) in the SHOWER ESCUTCHEON (2) and rotate
the ESCUTCHEON (2) so that SET SCREW (12) faces the center of the tub. 
Retighten the SET SCREW (12).

Thread the HOLDER (1) into the SHOWER ESCUTCHEON (2).

Insert a SEAL WASHER (4) into the SHOWER HOSE CONNECTOR (5)
and hand tighten HAND SHOWER (13) into SHOWER HOSE CONNECTOR (5). 
Place the HAND SHOWER (13) into the HOLDER (1).

INSTALL HAND SHOWER

TEST INSTALLED DIVERTER

4

Turn DIVERTER VALVE (1) fully clockwise (Tub fill position).

Lift HANDSHOWER (2) from holder, direct spray into tub, turn 

DIVERTER VALVE (1) fully counter-clockwise to check 

HANDSHOWER (2) and HOSES (3) for leaks.  With DIVERTER 

VALVE (1) in counter-clockwise position, flow should only come 

from HANDSHOWER (2).

Turn control valves "off."

Turn on control valves and check all connections for leaks.  With

DIVERTER VALVE (1) in clockwise position, flow should only come 

from tub spout.

5

1

2

3

2

3

5

4

2

6

7

12

8

10

11

13

13

1

1

9

EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with 
clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

M 9 6 8 8 4 2   R E V   1 . 1

Отзывы: