8
CARE:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
SERVICE
7
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
1
2
3
4
If Faucet Drips Proceed As Follows:
Turn VALVE in OFF position.
If faucet drips, operate HANDLE several times from OFF to ON position.
Do not apply excessive force.
FLOW CONTROL DEVICE may accumulate dirt. To remove the FLOW
CONTROL DEVICE, unthread SPRAY AND HOSE ASSEMBLY and
rinse clean FLOW CONTROL DEVICE.
Remove INDEX BUTTON
(1)
, loosen HANDLE SCREW
(2)
and remove HANDLE
(3)
.
Unthread ESCUTCHEON CAP
(4)
. Unthread three MOUNTING SCREWS
(5)
.
Lift CARTRIDGE
(6)
off MANIFOLD
(7)
and remove CARTRIDGE SEALS
(8)
.
Place SEALS
(8)
into CARTRIDGE PORTS
(6a)
.
Replace ESCUTCHEON CAP
(4)
, HANDLE
(3)
, tighten HANDLE
SCREW
(1)
and install INDEX BUTTON
(2)
.
Test fitting.
Clean MANIFOLD
(7)
, CARTRIDGE
(6)
ports and SEALS
(8)
.
Place CARTRIDGE
(6)
onto MANIFOLD
(7)
and tighten MOUNTING
SCREWS
(5)
alternately.
5
6
8
7
6a
M 9 6 5 4 5 6 Rev. 1. 2
Flow Control
Device
Spray and Hose
Assembly