PIPING PREPARATION

305/400mm

*220

*180

2

4

3

MARK MOUNTING HOLES

PUNCHING

A.

A.

305/400mm

B.

INSTALL FLOOR FIXING SET

Unit: mm

WATER SUPPLY PIPE : Connecting size G1/2”.

WASTE PIPE : Size Ø108mm or 102mm (PVC, Pipe

Class 8.5 or a regular pipe with an internal diameter

of 108mm or 102mm at the connecting point with the

toilet and a gradient of 2cm, per 100cm.)

Remark: Ø108mm is for Korea, Ø102mm is for China.

AIR VENT : Size not smaller than Ø1-1/2” and must

connected directiy to the waste pipe.

Insert the flange into the waste outlet

pipe, ensuring that the arrow is pointing

toward the floor.

Set proprely the VC on the floor, mark the

location to be drilled. (the figure just as

reference)

Using

Ø10mm masonry drill bit, drill the floor to

connect the floor fixing set, follow floor fixing set,

follow in the figures.

Install the floor fixing set and plastic trapway at the

assigned location. 

305/400mm

drill

10mm.

B.

   

305/400mm