PIPING PREPARATION
305/400mm
*220
*180
2
4
3
MARK MOUNTING HOLES
PUNCHING
A.
A.
305/400mm
B.
INSTALL FLOOR FIXING SET
Unit: mm
WATER SUPPLY PIPE : Connecting size G1/2”.
WASTE PIPE : Size Ø108mm or 102mm (PVC, Pipe
Class 8.5 or a regular pipe with an internal diameter
of 108mm or 102mm at the connecting point with the
toilet and a gradient of 2cm, per 100cm.)
Remark: Ø108mm is for Korea, Ø102mm is for China.
AIR VENT : Size not smaller than Ø1-1/2” and must
connected directiy to the waste pipe.
Insert the flange into the waste outlet
pipe, ensuring that the arrow is pointing
toward the floor.
Set proprely the VC on the floor, mark the
location to be drilled. (the figure just as
reference)
Using
Ø10mm masonry drill bit, drill the floor to
connect the floor fixing set, follow floor fixing set,
follow in the figures.
Install the floor fixing set and plastic trapway at the
assigned location.
305/400mm
drill
10mm.
B.
305/400mm