background image

Installation Instructions:

Instrucciones De Instalación:

pg

4

Press firmly.

Presionar firmemente.

1

2

BACK-TO-BACK INSTALLATION

INSTALACIÓN EN OPOSICIÓN

Apply weight 

evenly. Do not 

move after 

placement.

Water tight

seal may

break.

Distribuya el peso 

uniformemente. No 

lo mueva una vez 

colocado. El sello 

apretado del agua 

puede romperse.

3

Recommended fitting type for 

back-to-back installations.

Tipo de accesorio recomendado para 

instalaciones en oposición.

D

epending upon your plumbing and venting conditions, the flow from this toilet in a back-to-back 

installation may create a vacuum on the system and draw water from the opposing bowl. The 
National Standards Plumbing Code prohibits the use of a cross fitting for drainage as throw over 
is possible. The code does approve a directional "Y" style fitting with proper venting to direct the 
water downward and away from the other toilet.

Según las condiciones de plomería y ventilación, el flujo de este inodoro en una instalación espalda con 
espalda puede crear un vacío en el sistema y tomar agua de la taza contraria. El Código Nacional de Normas 
de Plomería (National Standards Plumbing Code) prohíbe el uso de un accesorio cruzado para el drenaje, 
debido a la posibilidad de rechazo. El código aprueba un accesorio direccional tipo "Y" con una ventilación 
adecuada para dirigir el agua hacia abajo y lejos del otro inodoro.

44

!

Apriete a mano 

solamente. No 

apriete de más.

Hand tighten

only. Do not

overtighten.

Содержание Homestead VorMax 745AA Series

Страница 1: ...rce Test Report No 109 141486 002 comparing VorMax against conventional under the rim water dispersal toilets from major retailers GRACIAS Bienvenido a su nuevo inodoro de alto rendimiento VorMax con...

Страница 2: ...ions page 4 Care and Cleaning page 6 Troubleshooting Guide page 7 Warranty page 8 TABLA DE CONTENIDOS Dentro De La Caja page 3 Antes De Comenzar La Instalaci n page 3 Quitando Un Inodoro Existente pag...

Страница 3: ...ponja Antes De Quitar El Excusado Clean Flange Placa Limpia Before You Start Antes De Comenzar La Instalaci n For Assistance Call Customer Care at 800 442 1902 Para asistencia llame a Atenci n al clie...

Страница 4: ...ing bowl The National Standards Plumbing Code prohibits the use of a cross fitting for drainage as throw over is possible The code does approve a directional Y style fitting with proper venting to dir...

Страница 5: ...en la conexi n del suministro de agua de este tanque Si existe una fuga en la conexi n despu s de haber apretado manualmente la conexi n cambie la l nea de suministro Si persiste la fuga con la nueva...

Страница 6: ...ORKS VorMax Flush Technology reinvents conventional toilet flushing to provide the cleanest flush ever engineered The patent pending innovative VorMaxflushing system is powered by dual injection flush...

Страница 7: ...rcialmente bloqueados d La presi n del suministro de agua es muy baja e El tanque no est instalado de manera ajustada sobre la taza f El producto tiene aire atrapado en las v as de agua g Nivel del ag...

Страница 8: ...e the product for the same or a similar model This limited warranty applies only to the original non commercial purchaser and installation of the products In the event of a limited warranty claim proo...

Отзывы: