background image

4

TESTING

Turn the HOT HANDLE 

(1)

 clockwise and the

COLD HANDLE 

(2)

 counterclockwise to the

off position.

Unscrew and remove the SPOUT STREAM

STRAIGHTENER

(3)

.

Slowly turn on the water supplies.

Operate the HANDLES 

(1, 2)

 to flush water

lines thoroughly. Check SPOUT 

(4)

 connection

for leakage.

Turn the Handles off.  Replace the SPOUT

STREAM STRAIGHTENER 

(3)

.

1

2

3

4

M 9 6 8 6 5 2   R e v.   1 . 1

2

VALVE TRIM

6

5

SERVICE

Place the ESCUTCHEON SEALS 

(1)

 over the VALVE BODIES 

(2)

.

Thread the VALVE ESCUTCHEONS 

(3)

 into the VALVE BODIES 

(2)

.

Align the HANDLE STEM 

(4)

 with the SLEEVE 

(5)

 as necessary.

Thread the VALVE ESCUTCHEON 

(3)

 into the BODIES 

(2)

 until the

ESCUTCHEON

(3)

 contacts the finished deck.

3

INSTALL HANDLES

Turn off the water supplies

Turn HANDLE 

(1)

 to the off position.

Remove the INDEX CAP 

(2)

 and the HANDLE

SCREW

(3)

. Pull the HANDLE BASE 

(4)

 off and

remove ADAPTER 

(5)

.

Unscrew the VALVE ESCUTCHEON 

(6)

.

Unscrew  the VALVE LOCK NUT 

(7)

 and

remove. A 17mm deep socket is required.

Remove the CARTRIDGE 

(8)

 by

pulling up on the SLEEVE 

(9)

.

Remove the SCREW 

(10)

from the CARTRIDGE (8).

Remove the SPRING CLIP 

(11)

.

Remove the STOP WASHER 

(12)

.

Turn it 90˚ and replace.

Replace the SPRING CLIP 

(11)

.

Reverse the above steps to

reassembly the components.

If the spout drips, operate the handles several

times from the off to the on position. Do not

force - the handles only turn 90˚

90

$

To change the direction of handle rotation

Turn VALVE into OFF position.

Push ADAPTER

 (1)

 into HANDLE 

(2)

in a way that the male square on the

ADAPTER

(1)

 fits in the female square

of the HANDLE 

(2)

.

Push HANDLE 

(2)

 and ADAPTER 

(1)

onto VALVE STEM 

(4)

.

Turn VALVE into OFF position.

Push ADAPTER 

(1)

 into

HANDLE BASE 

(2)

.

Push HANDLE BASE 

(2)

and ADAPTER 

(1)

onto

VALVE STEM 

(3)

.

Push CROSS 

(4)

 onto

ADAPTER

(1)

.

Assemble and tighten
HANDLE SCREW 

(5)

.

Push INDEX CAP 

(6)

 in

top of HANDLE 

(4)

.

Push out ADAPTER 

(1)

 carefully.

Turn ADAPTER 

(1)

 either 45˚ or 90˚

so that male square on ADAPTER 

(1)

catches different female square in

HANDLE BASE 

(2)

.

Assemble and tighten HANDLE

SCREW

(3)

.

Push INDEX CAP 

(5)

 in top of HANDLE 

(2)

.

Check alignment, if not satisfactory aligned;

LEVER HANDLE

CROSS HANDLE

2

3

4

1

5

6

7

10

9

11

12

8

1

2

3

4

5

1

1

2

2

3

3

4

4

6

5

5

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with clean
water may also be used, if desired. No additional cleaning products are required.

EverClean™ Finish Care Instructions

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

Отзывы: