background image

TEST INSTALLED FAUCET

2

Remove AERATOR.

With handles in OFF position, turn on water supplies and check all connections for leaks.

Operate both handles to flush water lines thoroughly.

Turn handles into OFF position and replace AERATOR.

1

INSTALL FAUCET

Turn off hot and cold water supplies before beginning.

CAUTION

Place faucet in position on sink.

Assemble and tighten LOCKNUTS from underside of SINK.

Connect the HOT water supply to the left SHANK and the
COLD water supply to the right SHANK using appropriate
connectors and sealant (not supplied), and COUPLING NUTS.

LOCKNUT

HOT

COLD

COUPLING NUT

PUTTY

PLATE

BODY

SINK

SHANK

NOT SUPPLIED

Check alignment, if not satisfactory
aligned;

Push out ADAPTER carefully.

Turn ADAPTER either 45˚ or 90˚
so that male square on
ADAPTER catches different
female square in HANDLE BASE.

Assemble and tighten
MOUNTING SCREW.

Push INDEX CAP in top of
HANDLE.

SERVICE

Handle alignment.

3

To change direction of handle rotation, 
proceed as follows:

AERATOR may accumulate dirt causing distorted and reduced
water flow.  Remove AERATOR and rinse clean.

If spout drips, operate handles several times from OFF to ON
position.  Do not force - handles turn only 90

$

.

SPRING

CLIP

STOP

WASHER

90

$

Turn valve to OFF position.
Pull out INDEX CAP and remove
HANDLE SCREW.  
Pull off HANDLE BASE and remove
ADAPTER.
Remove SPRING CLIP.
Lift STOP WASHER, turn 90

$

 and replace.

Replace SPRING CLIP.
Reinstall HANDLE.

VALVE

STEM

FEMALE SQUARE
IN HANDLE BASE

HANDLE

ADAPTER

SQUARE

4

EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with 
clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

.        3 & 7    