5
SERVICE
2
4
5/16'' MIN.
MOUNTING
SURFACE
FOR FITTING
LESS SPRAY
11
11
10
1
3
4
Push TUBING
(3)
ends into VALVE
(4)
side outlets. Insert VALVES
(4)
into mounting holes from underside of ledge.
Press TEE
(5)
onto SPOUT SHANK
(6)
making certain that the O-RING
(7)
is
properly seated on SHANK
(6)
. Push COUPLING
(8 or 8a)
into TEE
(5)
and
attach to SPOUT SHANK
(6)
and tighten. For 7005.901 use a 10 mm
(3/8") hex key.
Install LOCKNUTS
(1)
and RUBBER WASHERS
(2)
onto valve shanks.
Place RUBBER RING
(10)
into ESCUTCHEON ADAPTERS
(9)
and thread onto
valves until snug against internal stop.
Tighten LOCKNUT
(1)
to secure VALVE
(4)
position.
Slide FERRULE
(12)
and COUPLING NUT
(13)
to outlet of VALVE
(4)
and tighten
COUPLING NUT
(13)
firmly.
Connect HOT water supply to inlet of left VALVE and COLD water supply to inlet of
right VALVE using appropriate connector.
VALVE ASSEMBLY
HOT
COLD
12
13
7
6
8
8a
5
13
12
3
4
MOUNTING
SURFACE
Thread of VALVE BODY
(4)
should extend at least 5/16 inch above
MOUNTING SURFACE
(11)
. If necessary, adjust LOCKNUT
(1)
.
10
9
9
M968595 Rev.1.2
INSTALL HANDLES
To change direction of handle:
8
7
1
2
4
4a
5
3
TOP
SPLINE END DOWN
Push ADAPTER
(1)
on VALVE STEM
(2)
, so that the hole of the
ADAPTER
(1)
without a spline is facing up.
Fig. A.
Tighten
STEM SCREW
(3)
to secure ADAPTER
(1)
.
Find correct position of LEVER HANDLE ASSEMBLY
(4)
by adjusting
male teeth on ADAPTER
(1)
to female teeth in HANDLE
(4).
Push
LEVER HANDLE ASSEMBLY
(4)
down onto ADAPTER
(1).
Thread base of LEVER HANDLE ASSEMBLY
(4a)
onto DECK
ADAPTER
(5)
until snug against mounting surface.
Fig.
A.
2
90˚
If spout drips, operate handles several times from OFF to ON position.
Do not force - handles turn only 90˚.
3
2
4
Turn valve to OFF position
Thread HANDLE BASE
(1a)
counter clock-wise until loose.
Pull HANDLE
(1)
“UP” firmly to release from ADAPTER
(2)
.
Remove SPRING CLIP
(3)
. Lift STOP WASHER
(4)
, turn 90˚
and replace. Replace SPRING CLIP
(3)
.
Re-install HANDLE ASSEMBLY
(1)
.
1
1a
insta
ll
re
move