background image

SERVICE

To change direction of handle rotation, proceed as follows:

Turn HANDLE to OFF position.
Remove HANDLE SCREW and HANDLE.
Remove SPRING CLIP 

(1)

.

Lift STOP WASHER 

(2)

, turn 90

p

 and replace.

Replace SPRING CLIP 

(1)

.

Replace HANDLE and HANDLE SCREW.

AERATOR may accumulate dirt causing distorted and reduced water flow.
Remove AERATOR and rinse clean.

If spout drips, operate handles several times from OFF to ON position.
Do not force - handles turn only 90

p

.

90

p

FINISH INSTALLATION

Apply thread sealant or teflon tape to SUPPLY NIPPLES 

(1)

.

Slide COUPLING NUTS 

(2)

onto INLET SHANKS 

(3)

.

Thread ESCUTCHEONS 

(4)

fully onto INLET SHANKS 

(3)

.

Thread INLET SHANKS 

(3)

onto SUPPLY NIPPLES 

(1)

. Distance

between INLET SHANK 

(3) 

outlets must be 8" to match the VALVE 

(5)

.

Insert RUBBER WASHERS 

(6)

into INLET SHANK 

(3)

.

Attach VALVE 

(5)

to INLET SHANKS 

(3)

.

Tighten both COUPLING NUTS 

(2)

firmly.

Remove AERATOR 

(1)

.

Turn HANDLES TO 

OFF

 POSITION.

Slowly turn water supplies on and check all connections for leaks.

Operate HANDLES to flush water lines thoroughly.

Turn HANDLES to 

OFF

 position and replace AERATOR 

(1)

.

Thread ESCUTCHEONS against finished wall.

TEST FAUCET

.        3 & 7     

1

1

1

2

2

3

4

5

6