STUD FLANGE BRACKET INSTALLATION
PROVIDED WITH THE BATH IS A PACKAGE OF (4) FOUR STUD FLANGE BRACKETS AND (8) EIGHT SCREWS. INSTALL BRACKETS AND
SCREWS AS SHOWN IN WALL BRACKET INSTALLATION DETAIL. TWO BRACKETS SHOULD BE LOCATED EVENLY ACROSS THE BACK TILE
FLANGE AND INSTALL ONE BRACKET ON EACH END OF THE BATH, TOWARDS THE FRONT END OF THE TILE FLANGE. THIS WILL ALLOW
TILE FLANGE TO BE HELD SECURELY AGAINST STUDWALL OF RECESS INSTALLATION.
BATH
FLANGE
DRYWALL
SCREW
STUD
FLANGE
BRACKET
STUD
BATH
TYPICAL RECESS INSTALLATION
STUD FLANGE BRACKET
INSTALLATION
610mm
(24)
305mm
(12)
1527mm
(60-1/8)
533mm
(21)
7 7
5 m
m
( 3
0 )
8 1
3 m
m
( 3
2 )
TUB WIDTH
1 X 3 X 8
L E V E L I N G
S T R I N G E R
1 X 3 L E V E L I N G
S T R I N G E R
2 X 4
S T R I N G E R
S U P P O R T
WHIRLPOOL ONLY:
UNLESS AN ACCESS OPENING OF AT LEAST
305mm X 610mm(12" X 24") IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
SECURE THE BATH TO THE STUDS
AS SHOWN USING THE SCREWS
AND BRACKETS PROVIDED -
SEE STUD FLANGE BRACKET
INSTALLATION
TILE
WALL
BOARD
LEVELING
STRINGER
BATH
ADHESIVE
SEALANT
FRAMING AND INSTALLATION
BATH MAY ONLY BE INSTALLED ABOVE THE FLOOR LINE IN A RECESS TYPE INSTALLATION, AS SHOWN IN RECESS
INSTALLATION DIAGRAM.
THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS: STRINGER OR PIER HEIGHT SHOULD BE AS
INDICATED. THE SUMP OF THE BATH IS SUPPORTED BY INTEGRAL FEET AND NO ADDITIONAL SUMP SUPPORT IS
REQUIRED. ONCE THE BATH IS IN PLACE, THE FEET SHOULD BE SHIMMED ACCORDINGLY, SO THAT THE RIM OF THE BATH
CONTACTS THE STRINGER OR PIER BUT SUPPORTS NO WEIGHT. ANY FINISH MATERIAL, SUCH AS TILE OR WALL BOARD,
MUST BE SELF-SUPPORTING IF IT CONTACTS THE RIM OF THE BATH.
LOCATE STUDS AS REQUIRED. INSURE ROUGH DIMENSIONS ARE PROPER, PLUMB AND SQUARE. FOR REAR MOTOR
MOUNT WHIRLPOOLS, PROVISION MUST BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING
PUMP AND CONTROLS.
752352-100 REV. H
(2)
SPIC AND SPAN® IS A REGISTERED TRADEMARK OF PROCTER & GAMBLE