background image

755741-100 EN

1

All product names listed herein are trademarks of AS America, Inc. unless otherwise noted.

For questions or service issues, please call Technical Support 1-(800)-442-1902.

Please do not contact or return product to the store.

Models 3571, 3573

INSTALLATION AND 

OPERATION MANUAL

Green Tea

®

 Bathtubs

THANK YOU...

for selecting an American Standard bath. Your new bath is shipped to you after careful inspection. All you need 
to finish the installation are your selected fittings.
To ensure maximum performance and pleasure from this product, please follow the instructions and cautions. 

!

!

!

!

!

!

!

!

WARNING: Risk of hyperthermia and possible drowning.

 People using medications and/or having adverse medical 

history should consult a physician before using this product.

WARNING: Risk of personal injury.

 Do not overfill bathtub before entering. Entering tub when filled more than 2/3 can 

cause overflow and slippery conditions. Exercise caution when entering and exiting.

WARNING: No Food or Alcoholic Beverages.

 Use of your bathtub immediately after meals is not recommended.  

Avoid alcohol consumption before or during bathing. Alcoholic beverages can cause drowsiness or hyperthermia 

resulting in loss of consciousness or even drowning.  

Use this unit only for its intended use as described in this manual. 

Do not use any attachments not recommended by American Standard.

SA

VE 

THESE INS

TR

UCTIONS

Each bath arrives ready for installation however, a drain/overflow kit is required for each bath and it is not included.

The variety of installations for this bath may require framing procedures other than those shown. Locate studs as required. 

Ensure roughing-in dimensions are proper, plumb, and square. 

INSTALLATION AND FRAMING INSTRUCTIONS

Remove the bath from the carton. Retain the shipping carton until satisfactory inspection of the product has been 

made. 

Do not lift the bath by the plumbing at any time; handle by the shell only.

All bath units are factory tested for proper operation and watertight connections prior to shipping. 

Prior to 

installation, the bath must be filled with water and operated to check for leaks that may have resulted 

from shipping damage or mishandling.

The sumps of these baths are supported by feet and no additional sump support is required. 

Once the 

bath is in place, the feet should be shimmed and secured accordingly so that the rim of the bath 

contacts the stringer or pier but supports no weight.

It is strongly recommended that an additional opening be provided for access to drain components.  

Each bath has a nominal length (L), width (W), and Height (H) along with a rim height. Unless otherwise noted 

in the following rough-in references, assume that the nominal tolerances are as much as +/-1/4 inch (6mm). 

Therefore, it is strongly recommended that the installer build the surrounding structure after receiving the actual 

bath. Structural measurements should be verified against the actual bath received to ensure proper fit.

Содержание DEEP SOAK 1640.305 Series

Страница 1: ...INSTRUCTIONS Each bath arrives ready for installation however a drain overflow kit is required for each bath and it is not included The variety of installations for this bath may require framing proce...

Страница 2: ...support structure per the local codes Note the bath deck must be self supporting 3 Cut bath deck to your specifications 4 Place the bath deck in position and trace the opening on the tub with a soft...

Страница 3: ...m 2 51mm C L OF OVERFLOW LEVELING STRINGER NOT FOR SUPPORT 72 1829mm 36 914mm 11 1 2 292mm 14 3 4 375mm C L 9 229mm 19 483mm 2 51mm OUTLINE OF CUTOUT 70 5 x 34 5 1780 x 876mm 21 533mm 4 102mm INTEGRAL...

Страница 4: ...wing 1 Defect or damages arising from shipping installation alterations accidents abuse misuse lack of proper maintenance and cleaning as directed in the Installation Instruction Manual and use of oth...

Страница 5: ...100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Plumbers Putty or Caulking Phillips Screwdriver Channel Locks DEEP SOAK BATH DRAI...

Страница 6: ...3 Apply sealant to threads of TAILPIECE 6 and thread into DRAIN TEE 3 Install OVERFLOW GASKET 4 to OVERFLOW TUBE ASSEMBLY 2 Adjust OVERFLOW GASKET 4 to couture of tub FIG 1 Loosen SLIP JOINT NUT SEAL...

Страница 7: ...r below floor Fig 1 TYPICAL ABOVE FLOOR INSTALLATION 4 ABOVE FLOOR OUTLET INSTALLATION STANDARD DRAIN ABOVE FLOOR ROUGH BELOW FLOOR ROUGH TUB NOTE TUB IS SHOWN CUT AWAY FOR CLARITY OF INSTALLATION DO...

Страница 8: ...to 6 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2007 754129...

Страница 9: ...with LOCKNUT 6 Supplied with Fittings MOUNTING SURFACE 165 mm to 305 mm ADJ 6 1 2 TO 12 38 mm 1 1 2 MAX 32 mm 1 1 4 MAX 31 mm 1 3 16 DIA 76 mm 3 1 2 NPT 1 2 NPT 40 mm 1 5 8 DIA H C 29 mm 1 1 8 DIA 20...

Страница 10: ...ly Check with local plumbing codes for backflow prevention requirements Install a backflow prevention device if required DIVERTER INSTALLATION FITTING MOUNTING SURFACE WATER INLET FROM TEE TUB OUTLET...

Страница 11: ...from HANDLE ADAPTER 3 Loosen the adapter screw 4 Use a flat blade screw driver to remove SPRING CLIP 5 Lift STOP WASHER 6 turn 90 and replace Replace SPRING CLIP 5 Reinstall HANDLE ASSEMBLY 2 and tigh...

Страница 12: ...ER 2 and HOSES for leaks Turn VALVES off If spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 TEST INSTALLED FAUCET CAUTION The flow rate of this Tub...

Страница 13: ...0070A TUBE TEE ASSEMBLY M970262 0070A SHANK KIT 030274 0070A SHANK MOUNTING KIT 911903 0070A RUBBER RING 028664 YYY0A HAND SHOWER HOLDER 1660207 XXX HAND SHOWER 918319 0070A SCREW M918464 0070A SPINDL...

Отзывы: