American Standard Colony PRO 7075.000 Скачать руководство пользователя страница 4

- 3 -

    

M965766 (8/16)

6

7

•  With HANDLE 

(1)

 in OFF position, turn on WATER

SUPPLIES 

(2) 

and check all connections for leaks.

•  Remove AERATOR 

(3)

.

•  Operate HANDLE 

(1)

 to flush water lines thoroughly.

•  Replace AERATOR 

(3)

.

CHECK DRAIN CONNECTIONS

•  Operate POP-UP KNOB 

(4)

 and fill lavatory with water.

Check that DRAIN STOPPER 

(5)

 makes a good seal

and retains water in Sink.

•  Release POP-UP KNOB 

(4)

 down and check all drain

connections and 

“P”

 trap for leaks.        Tighten

if necessary.

•  To remove or replace cartridge:

– Turn valve to OFF position.
– Pull out PLUG BUTTON 

(1)

 and remove HANDLE SCREW 

(2)

.

– Pull off HANDLE 

(3)

 and CAP 

(4)

.

– Pull out CARTRIDGE 

(5)

.

– Inspect CARTRIDGE 

(5)

 and O-RINGS 

(6)

 for debris and

clean if necessary.

– Clean MANIFOLD 

(7)

 and rinse clean.

– Reinstall CARTRIDGE 

(5)

 and O-RINGS 

(6)

 onto

MANIFOLD 

(7)

.

– Reinstall CAP 

(4)

 and HANDLE ASSEMBLY 

(3)

.

•  If spout drips, operate handle several times from OFF to ON

and HOT to COLD position. Do not force - handle turns only 90˚.

ADJUST HOT LIMIT SAFETY STOP

By restricting HANDLE rotation and limiting the amount of

hot water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP 

(8)

 reduces risk of accidental scalding. To lower the

maximum hot water temperature of your faucet, all you need to
do is adjust the setting on the HOT LIMIT SAFETY STOP 

(8)

.

Note: The HOT LIMIT SAFETY STOP 

(98

 is set at the neutral

setting from the factory. 

Fig. A.

•  To adjust HOT LIMIT SAFETY STOP:

– Remove HANDLE ASSEMBLY 

(3)

, CAP 

(4)

– Set the CARTRIDGE STEM 

(9)

 to the OFF position.

– Lift up the HOT LIMIT SAFETY STOP 

8)

.

– Place the HOT LIMIT SAFETY STOP 

(8)

 in the desired GRAY

SHADED AREA 

(10)

 to limit the hot water.  

Fig. B

.

– Reinstall CAP 

(4)

 and HANDLE ASSEMBLY 

(3)

.

SERVICE

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.

TEST INSTALLED FITTING

5

1

4

3

OFF

ON

HOT

COLD

“P” TRAP

WASTE

OUTLET

2

2

CAUTION

Turn off hot and cold water 

supplies before beginning.

7

4

5

6

9

8

1

2

2.5mm HEX KEY

+HOTTER

COLDER

8

9

A

B

10

SETTING

MARKS

P-2, P-2B - 7075.050

Содержание Colony PRO 7075.000

Страница 1: ...Way South Portland Maine Phone 207 772 8364 Fax 207 773 4571 PLUMBING HEATING COOLING AND INDUSTRIAL SUPPLIES SERVING NEW ENGLAND NEW YORK SINCE 1866 WARREN MECHANICAL HARTLEY BLOCK O M FIXTURES 06 08...

Страница 2: ...MENDED TOOLS 1 M965766 8 16 INSTALL FAUCET COLONY PRO SINGLE CONTROL CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 7075 054 7075 055 7075 056 7075 050 7075 004 7075 005 7075 006 7075 002 7075 00...

Страница 3: ...ROD E and tighten THUMBSCREW 6 Remove one end of CLIP 8 from PIVOT ROD 9 by squeezing ENDS TOGETHER WHILE SLIDING Insert PIVOT ROD 9 into second or third hole in EXTENSION ROD 7 and reassemble CLIP 8...

Страница 4: ...MIT SAFETY STOP By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold the HOT LIMIT SAFETY STOP 8 reduces risk of accidental scalding To lower the maximum ho...

Страница 5: ...0070A AERATOR 0 5 GPM 4 M965766 8 16 COLONY PRO SINGLE CONTROL CENTERSET LAVATORY FAUCET MODEL NUMBERS Replace the YYY with appropriate finish code POLISHED CHROME 002 LEGACY BRONZE 278 SATIN NICKEL 2...

Страница 6: ...ME A112 18 1 CSA B125 1 WaterSense 1 5 gpm 5 7 L min 2 0 gpm 7 6 L min S 9600 P Origins Shower Valve S 9600TS P Origins Tub Shower Valve S 9601 P Origins Shower System S 9602 P Origins Tub Shower Syst...

Страница 7: ...S 9600TS P Ref 42 1067 mm S 9601 P S 9600 P H Male 1 2 NPT fitting must protrude 4 from finished wall I 5 1 2 140 mm J 2 1 2 64 mm K 2 3 4 70 mm L 2 1 8 54 mm M 5 3 4 146 mm N 2 1 2 64 mm FLOOR FLOOR...

Страница 8: ...062 B Brass K Tub Spout 060 Parts Breakdown A HOT Water Supply COLD Water Supply B C D E F I F G K H J Notes 1 Apply a bead of silicone around the perimeter of all shower trim installed flush to the...

Страница 9: ...lve and secure with set screw H Install plug button I H I D 1 2 5 Install tub spout K to pipe fitting Turn clockwise to secure 1 K 2 6 Attach shower arm B and flange C to vertical shower pipe Turn clo...

Страница 10: ...e approximately 3 4 turn to put valve in hot position 1 Turn diverter handle left for tub spout operation Operation Diverter Control S 9600TS P and S 9602 P Only 2 Turn diverter handle right for showe...

Страница 11: ...information Compliance Certified by CSA Group Modifications Note Append appropriate suffix to model number ASME A112 18 1 CSA B125 1 WaterSense 1 5 gpm 5 7 L min 2 0 gpm 7 6 L min S 9603 PLR Origins H...

Страница 12: ...easurements A 3 76 mm B 3 1 2 89 mm C Male 1 2 NPT fitting must protrude 3 8 from finished wall D Shower Valve Hole Size Min 3 76 mm Max 4 102 mm E 3 5 8 92 mm F Rough in 2 3 8 1 2 60 mm 13 mm G Ref 3...

Страница 13: ...tyle Note Append STN to part number for Satin Nickel finish Replacement Parts Item Description Part Number A B Handle Assembly RTS 063 C Dome Cover T 19 D E Shower Escutcheon Kit Standard S 9600 PLR E...

Страница 14: ...ot holes into studs or wood blocking With slide bar J in position secure to wall using screws I Attach slide bar ends J1 to bar flanges J 3 3 3 I J1 1 2 3 Install dome cover C to valve Turn clockwise...

Страница 15: ...ly 3 4 turn to put valve in hot position Installation 9 Press tabs on wall ell flange Install wall ell K to pipe fitting Turn clockwise to secure 2 3 K 1 1 10 Attach hand shower H to hose N Attach hos...

Страница 16: ...ion Volume Control 1 Turn volume control handle left for high flow 2 Turn volume control handle right for low flow Troubleshooting Chart Problem Cause Solution Finish is spotting Elements in water sup...

Страница 17: ...gle Handle Kitchen Faucet MODEL HANDLE FINISH 8707 Lever Chrome Aerator 3919 Side Spray 1860 Chrome Cartridge 121549 Optional Deck Plate Handle Kit 121521 Screw Red Blue Plug Button Kit 40001 Side Esc...

Страница 18: ...ON THE UNDERSIDE OF THE HANDLE AFTER THE HANDLES HAVE BEEN REMOVED UNSCREW THE HANDLE NUTS AND PULL OUT ON THE CARTRIDGE ZURN WILL SUPPLY HANDLE PORT PLUGS ZURN PART 61094001 AT YOUR REQUEST 8 REPLACE...

Страница 19: ...DGE SHUT THE WATER OFF LOOSEN THE HANDLE NUTS AND PULL UP ON THE CARTRIDGE REPLACEMENT PARTS COLD WATER CARTRIDGE 59517001 HOT WATER CARTRIDGE 59517002 INDEX BUTTONS G60500 STOP PLUGASSEMBLY G67807 IT...

Отзывы: