American Standard Colony Corner 1730.002 Скачать руководство пользователя страница 2

H72

© 2008 AS America Inc.

COLONY CORNER™

WHIRLPOOL AND BATHING POOL

HIGH GLOSS

495mm

(19

-1/2)

117mm

(4

-5/8)

C/L OF DRAIN

OUTLET

51mm

(2)

1546mm

(60-7/8)

ALT.
PUMP

1064mm

(41-7/8)

686mm

(27)

318mm

(12-1/2)

1168mm

)

(46

1514mm

(59-5/8)

TOP OF

DECK

445mm

(17-1/2)

70mm

(2-3/4)

ROUGH

FLOOR

 83mm

(3-1/4)

BATH SUPPORT 

MATERIAL

38mm (1-1/2) 
O.D. TAILPIECE

PUMP

PROVIDE ACCESS 
FOR SERVICING
PUMP & CONTROLS

(6) JETS

ON/OFF
SWITCH

2 AIR 
VALVES

LEVELING 
STRINGER
NOT FOR 
SUPPORT

483mm

  (19)

2134mm

)

(84

*

BATH SUPPORT

MATERIAL

495mm

(19

-1/2)

6.3mm (1/4) INTEGRAL 
TILE FLANGE (2 SIDES)

 19mm (

)

3/4

C/L OF DRAIN
OUTLET

LEVELING STRINGER
NOT FOR SUPPORT

457mm

)

(18

38mm
(1-1/2)

1549mm

)

(61

1064mm

(

)

41-29/32

686mm

)

(27

686mm

)

(27

1168mm

)

(46

1511mm

(59-1/2)

876mm

(34-1/2)

876mm

(34-1/2)

TOP OF

DECK

56mm

)

(2-7/32

ROUGH

FLOOR

79mm (

)

3-1/8

101x101mm

4 x 4” FEET

38mm (1-1/2) O.D. TAILPIECE

  60 x 60 x 19-1/2 In.(1524 x 1524 x 495mm)

115 Lbs. (52 Kg.)

908 Lbs. (412 Kg.)

95 Gal. (360 L.)
65 Gal. (246 L.)

 30 x 50 In. (762 x 1270mm)

 45-1/2 x 63-1/2 In.(1156 x 1613mm)

13 In. (330 mm)

 36 Lbs./Sq. Ft. (177 Kgs/Sq. m.)

27.8

54

GENERAL SPECIFICATIONS FOR 1730 WHIRLPOOL

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

WHIRLPOOL ELECTRICAL SPECIFICATIONS

1.25 HP, 9.9 AMPS, 120V.

SYSTEM I PUMP

60 x 60 x 19-1/2 In. 

(1524 x 1524 x 495mm)

 95 Lbs. (43 Kg.)

888 Lbs. (403 Kg.)

95 Gal. (360 L)

30 x 50 In. (762 x 1270mm)

45-1/2 X 31-1/2 In. (1156 x 1613mm)

13 In. (330mm)

36 Lbs./Sq.Ft. (174 Kgs./Sq.m)

27.8

54

GENERAL SPECIFICATIONS FOR 1730 BATHING POOL

INSTALLED SIZE

WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

NOTES:

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUMP OF 

BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.

■ 

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.

CONCEALED PIPING NOT INCLUDED.

FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

● 

IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES:  CHECK FOR INTERFERENCE WITH CIRCULATING 

SYSTEM PIPING, DRAIN OVERFLOW, AND APRON INSTALLATION.  MOUNTING HOLES DRILLED BY INSTALLER.

PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.

IMPORTANT:  Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1. These 

measurements are subject to change or cancellation.  No responsibility is assumed for use of superseded or voided pages.

Revised 2/08

Отзывы: