background image

INSTALL POP-UP DRAIN

INSTALL BLACK GASKET

3

2

Install BLACK CONE GASKET 

(1)

 onto DRAIN BODY 

(2)

from below.

Note:

 The flat side of the BLACK CONE GASKET 

(1)

 must

face down.

4

Drop DRAIN BODY 

(4)

 through sink drain 

hole. Make sure WHITE FOAM GASKET 

(5)

is under flange of DRAIN BODY 

(4)

Fig.

 

B.

Note:

 No plumber’s putty or caulk is required.

The CABLE ATTACHMENT POINT 

(6)

 must

face towards the rear of the SINK. 

Fig.

 

B.

Remove CLEAR PLASTIC COVER 

(1)

. Remove

CARDBOARD SPACER 

(2)

 from under DRAIN

POP-UP 

(3)

Fig.

 

A.

2

REAR OF

SINK

4

5

6

3

1

SINK

DRAIN

HOLE 

Fig.

 

A.

2

1

FLAT SIDE OF

GRAY LOCKNUT

MUST FACE UP   

INSTALL GRAY LOCKNUT

5

Install GRAY LOCKNUT 

(1)

 onto DRAIN BODY 

(2)

from below SINK. 

Fig.

 

A.

 

Note:

 The flat side of the GRAY LOCKNUT 

(1)

must face up.

Tighten firmly by hand. No tools are required.

Check DRAIN FLANGE in SINK to ensure that

WHITE FOAM GASKET 

(3)

 is fully compressed

and not visible. 

Fig.

 

B.

POP-UP KNOB 

(1)

 must be fully down.  

POP-UP KNOB

Fig.

 

A.

Fig.

 

B.

Certified to comply with ANSI A112.18.1

Installation

Instructions

Centerset Lavatory Faucet with the

Speed Connect™ Drain 

*Your new American Standard faucet is designed to work only with the Speed Connect drain. Helpful tips for

removing your current drain can be found in the Troubleshooting section of these instructions.

TIPS FOR REMOVING YOUR OLD DRAIN:

Loosen nuts on P-Trap using channel locks. Suggest spraying nuts with spray lubricant to loosen any corrosion or

debris that may have built up. Remove P-Trap half from Tailpiece. Use bucket to catch any residual water in P-trap.

Unthread Pivot Rod Nut from Drain Body and remove. Pull Stopper out from Drain Body.

Loosen Mounting Nut as far down as it will go. Push Drain Body up into Sink and unthread Metal Flange from Drain

Body. Remove Drain Body from below sink.

Unthread Tailpiece from Drain Body.

Loosen and remove Mounting Nut and Gasket on Drain Body using channel locks. Suggest spraying nut with spray

lubricant to loosen any corrosion or debris that may have built up. Push Drain Body up into the Sink and remove.

Note: 

If Drain body rotates while loosening Mounting Nut, insert a screw driver into overflow hole to prevent Drain 

Body from rotating while Mounting Nut is removed. 

Adjustable Wrench

Phillips Screwdriver

Channel Locks

Recommended tools

METAL OR PLASTIC TWO PIECE

DRAIN BODY 

 

METAL DRAIN BODY WITH

PLASTIC TAILPIECE 

PLASTIC DRAIN BODY

WITH PLASTIC TAILPIECE 

UNTHREAD

METAL

FLANGE

STOPPER

WHEN DRAIN IS REMOVED FROM ABOVE SINK

WHEN DRAIN IS REMOVED

FROM BELOW SINK

MOUNTING

NUT

MOUNTING

NUT and

GASKET

METAL

DRAIN

BODY

PLASTIC

DRAIN BODY

PLASTIC

TAILPIECE

P-TRAP

HALF

PIVOT

ROD NUT

PIVOT

ROD NUT

SINK

STOPPER

SCREWDRIVER

STOPPER

MOUNTING

NUT and

GASKET

METAL OR

PLASTIC

DRAIN BODY

FINISHED

WALL

FINISHED

WALL

FINISHED

WALL

PLASTIC

TAILPIECE

PIVOT

ROD NUT

SINK

SINK

P-TRAP

HALF

P-TRAP

HALF

Adjustable Wrench

 Screwdriver

Channel Locks

To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.

Recommended tools

Tubing Cutter

For Drains that are removed from below Sink:

For Drains that are removed from above Sink:

COMPRESSION

NUT

COUPLING

NUT

FLEXIBLE

SUPPLIES

3/8 O.D.

BULL-NOSE

RISERS

Thread CABLE CONNECTOR 

(1) 

clockwise

onto DRAIN BODY CONNECTION 

(2)

 and

hand tighten. 

Fig.

 

A.

Your new POP-UP DRAIN installation is

now complete. 

Fig.

 

B.

Note: 

Tailpeice on pop-up drain is 1-1/4” O.D.

Fig.

 

B.

Fig.

 

A.

ATTACH CABLE CONNECTOR

6

2

1

Operate LIFT KNOB 

(1)

 to verify that STOPPER 

(2) 

opens and

closes. 

Fig.

 

B.

Note: 

If STOPPER 

(2)

 does not open and close properly then refer

to the “troubleshooting section” of these instructions.

CHECK OPERATION OF POP-UP

7

1-1/4” O.D.

Fig.

 

B.

1/2" PIPE

THREAD

Speed Connect™ Drain

Troubleshooting Guide

1

2

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled

as “Cam”  and “Cam Cap” in the illustration. 

Fig.

 

B.

Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain. 

Fig.

 

D.

Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal. 

Fig.

 

E.

The Stopper can now be removed by lifting it out of the Drain. 

Fig.

 

F.

CAM

CAM CAP

RE-ATTACH

DISCONNECT

CABLE ADJUSTMENT PROCEDURE

If sink does not hold water even though Stopper is in the “down” position:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If Stopper does not raise up fully or sink drains too slowly

:

     • Follow CABLE ADJUSTMENT PROCEDURE.

If you need to remove the Stopper:

     • Follow STOPPER REMOVAL PROCEDURE.

If you would like the ability to remove your Stopper simply by lifting it out of the drain:

     •

 Follow STOPPER INSTALLATION PROCEDURE for 

“Unlocked” mode

.

 

                                                                          

Fig.

 

A.

Fig.

 

B.

REMOVE

CAM CAP

REMOVE

CAM

Fig.

 

D.

Fig.

 

E.

Disconnect the Cable from the Drain by threading the Cable Connector 

(1)

 counter-clockwise. 

Fig.

 

A.

Look at the area on the Drain Body where the Cable was attached and locate the component labeled as

“Cam” in the illustration. 

Fig.

 

B.

Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the

Stopper should be in the UP position. 

Fig.

 

B, C.

 

Push DOWN on the Lift-Knob to make sure it is fully down. 

Fig.

 

C.

Re-attach the Cable to the Drain Body Connection 

(2)

 by threading the Cable Connector 

(1)

 clockwise onto the

Drain Body Connection 

(2)

 and hand-tighten. 

Fig.

 

A.

STOPPER REMOVAL PROCEDURE

STOPPER INSTALLATION PROCEDURE

Locked Mode:

 

Look at the Plastic Loop at the bottom of the Stopper and notice

that the Loop is on one side of the Stopper. 

Fig.

 

G.

To install the stopper in 

“Locked”

 mode, insert the Stopper into

the Drain so that the Plastic Loop is facing toward the 

rear

 of the

Sink and the American Standard logo is facing 

front

. Rotate

Stopper slightly if necessary so that the Stopper slides all the

way down.

Fig.

 

G.

Re-install the Cam into the Drain, rotating the Cam if necessary

to make sure it is fully inserted. 

Fig.

 

J.

Re-install the Cam Cap, making sure the guide teeth are facing

outward. If the Cam Cap does not “snap” into place, then rotate

the Cam to make sure it is fully inserted. 

Fig.

 

K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

Troubling Shooting Guide to complete installation. Stopper will be

in 

“Locked”

 mode and not be removable.

Unlocked Mode:

 

Look at the Plastic Loop at the bottom of the Stopper and notice

that the Loop is on one side of the Stopper. 

Fig.

 

H.

To install the stopper in 

“Unlocked”

 mode, insert the Stopper into

the Drain so that the Plastic Loop is facing toward the 

front

 of the

Sink and the American Standard logo is facing 

rear

. Rotate Stopper

slightly if necessary so that the Stopper slides all the way down.

Fig.

 

H.

Re-install the Cam into the Drain, rotating the Cam if necessary

to make sure it is fully inserted. 

Fig.

 

J.

Re-install the Cam Cap, making sure the guide teeth are facing

outward. If the Cam Cap does not “snap” into place, then rotate

the Cam to make sure it is fully inserted. 

Fig.

 

K.

Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in

“Troublingshooting Guide” to complete installation. Stopper will be

in 

“Unlocked”

 mode and removable.

Fig.

 

J.

Fig.

 

K.

INSTALL

CAM CAP

CAM

INSTALL CAM

The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be

removed) or “Unlock” Mode (Stopper is removable).

1

INSTALL FAUCET

SINK OR

MOUNTING

SURFACE

POP-UP

CABLE

Turn off hot and cold water supplies before beginning.

Insert FAUCET 

(1)

 and CABLE CONNECTOR 

(2)

 through

mounting holes of Sink or mounting surface. 

Fig.

 

A.

Assemble LOCKNUTS 

(3)

 onto SHANKS 

(4)

 ( from under

side of Sink. Hand tighten firmly. 

Fig.

 

B.

 

2

2

1

3

3

4

Turn off hot and cold water

supplies before beginning.

CAUTION

(HAND TIGHTEN)

3

WHITE FOAM

GASKET

NOT VISIBLE

DRAIN

FLANGE

Fig.

 

B.

LOOP TOWARD

REAR OF SINK

Fig.

 

G.

LOGO

DRAIN

Unlocked Mode

LOOP TOWARD

FRONT OF SINK

180˚

LOGO

DRAIN

Fig.

 

H.

Connect water supply to FAUCET 

(1)

 with 1/2" IPS FLEXIBLE

SUPPLIES 

(2)

 or 3/8" O.D. BULL-NOSE RISERS 

(3)

.

Use adjustable wrench to tighten connections. Do not over tighten.

Be careful not to kink copper supply when bending. Use tubing

cutter to cut to proper length.

Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to

waste outlet.

MAKE WATER SUPPLY AND WASTE CONNECTIONS

8

FERRULE

1

2

3

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE

PURCHASED SEPARATELY.

HOT

COLD

2

4

1

9

TEST INSTALLED FITTING

With HANDLES 

(1)

 in OFF position, turn on WATER

SUPPLIES 

(2)

 and check all connections for leaks.

Remove AERATOR 

(3).

 Turn counter-clockwise to remove.

Operate both HANDLES 

(1)

 to flush water lines thoroughly.

Replace AERATOR 

(3)

. Turn clockwise to install.

5

1

2

3

CHECK DRAIN CONNECTIONS

Operate POP-UP KNOB 

(4)

 and fill lavatory with water.

Check that DRAIN STOPPER 

(5)

 makes a good seal

and retains water in SINK. If DRAIN STOPPER 

(5)

does not seal properly, please refer to Troubleshooting

section in these instructions.

Release POP-UP KNOB 

(5)

 down and check all drain

connections and "P" trap for leaks.      Tighten

if necessary.

11

“P” TRAP

WASTE

OUTLET

DOWN

UP

MODEL NUMBER

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1-800 442-1902

Weekdays 8:00 a.m. to 6:00 p.m. EST

IN CANADA  1-800-387-0369   (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

Product names listed herein are trademarks of American Standard Inc.

IN MEXICO  01-800-839-12-00

Fig.

 

C.

STOPPER

Fig.

 

F.

2

M962543-YYY0A

STOPPER

ASSEMBLY

M913208-0070A

SPONGE WASHER

M962551-0070A

CAM ASSEMBLY

M962431-0070A

DRAIN MOUNTING KIT

M952430-0070A

CABLE ASSEMBLY

M952410-YYY0A

 DRAIN ASSEMBLY

Fig.

 

A.

Fig.

 

B.

3/8” COMPRESSION

CONNECTION

1

8

2

7

3

4

5

6

CLARIDGE

 

   

Remove PLUG BUTTONS 

(1)

 on either side of ESCUTCHEON 

(2)

.

Loosen SET SEREWS 

(3)

 with 2.5mm hex wrench.

Pull SPOUT up while rotating side to side and remove

SPOUT & HANDLE 

(4)

 assembly to expose VALVES 

(7)

.

Remove SPRING CLIP 

(5)

 from valve .

Lift STOP WASHER 

(6)

, turn 90˚ and replace.

Replace SPRING CLIP 

(5)

.

Align SPOUT & HANDLE 

(4)

 assembly and install onto valve body.

When handles and spout are properly seated and aligned tighten

SET SCREWS 

(3)

 and replace PLUG BUTTONS 

(1)

.

AERATOR 

(8)

 may accumulate dirt causing distorted and reduced water flow.

Remove AERATOR 

(8)

 and rinse clean. Turn counter-clockwise to remove.  

Turn HANDLES to OFF position.

Turn Hot and Cold supplies off to faucet.

To change direction of handle rotation, proceed as follows:

10

SERVICE

6054.XXX

Centerset Lavatory Faucet with

Speed Connect™ Drain 

CLARIDGE

 

6054.XXX

M922881-YYY0A

AERATOR

M950219-YYY0A

LIFT ROD AND KNOB

M962670-YYY0A

HANDLE ASSEMBLY

065800-0070A

ATTACHMENT NUT

M910833-0070A

PUTTY PLATE

M 9 6 8 6 3 2

M 9 6 8 6 3 2

M 9 6 8 6 3 2

M 9 6 8 6 3 2

M 9 6 8 6 3 2

M 9 6 8 6 3 2

M 9 6 8 6 3 2

M 9 6 8 6 3 2

1

LIFT-

KNOB

994053-0070A

VALVE

M962671-0070A

BUTTON AND

SETSCREW

918049-0070A

ADAPTER

918555-0070A

HANDLE SCREW

5

6

90˚ 

4

7

1

3

If spout drips, operate handles several times from OFF to ON

position. Do not force - handles turn only 90˚.

Most existing drains can be removed quickly and easily with only a pair of channel-

lock pliers or a wrench. However, there may be situations where it is difficult to 

remove your old drain or determine how the drain is disassembled. Depending upon 

the existing Drain in your sink, it is either removed from above or below the sink. 

The illustrations below show some typical drain installations and how they are disas-

sembled from the sink.

The following tips can help with some of the more common challenges in drain removal: 

Congratulations on purchasing your American Standard faucet with

the Speed Connect Drain,  a feature found only on 

American Standard faucets.

Speed Connect Drain*

•  1/3 of the parts, installs in 1/3 of the time

•  No tools needed

•  Never needs adjustment

•  Guaranteed to seal properly the first time, every time.

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH  CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A

CLOTH WITH A COARSE SURFACE.

CARE INSTRUCTIONS:

1

2

FLAT SIDE OF GASKET

MUST FACE DOWN 

1

2

8

DOWN

Locked Mode

(Vandal Proof)

M923036-0070A

SNAP RING

© AS America, Inc. 2008

2.5mm

Hex wrench

CHROME

SATIN NICKEL

002

295

Replace the "YYY" with

appropriate finish code

Содержание Claridge Centerset Lavatory Faucet 6054.XXX

Страница 1: ...INSTALL FAUCET SINK OR MOUNTING SURFACE POP UP CABLE Turn off hot and cold water supplies before beginning Insert FAUCET 1 and CABLE CONNECTOR 2 through mounting holes of Sink or mounting surface Fig A Assemble LOCKNUTS 3 onto SHANKS 4 from under side of Sink Hand tighten firmly Fig B 2 2 1 3 3 4 Turn off hot and cold water supplies before beginning CAUTION HAND TIGHTEN Fig A Fig B 1 CLARIDGE 6054...

Страница 2: ...IC COVER 1 Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 Fig A 2 REAR OF SINK 4 5 6 3 1 SINK DRAIN HOLE Fig A 2 1 FLAT SIDE OF GRAY LOCKNUT MUST FACE UP INSTALL GRAY LOCKNUT 5 Install GRAY LOCKNUT 1 onto DRAIN BODY 2 from below SINK Fig A Note The flat side of the GRAY LOCKNUT 1 must face up Tighten firmly by hand No tools are required Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GAS...

Страница 3: ...rly then refer to the troubleshooting section of these instructions CHECK OPERATION OF POP UP 7 1 1 4 O D Fig B 1 2 PIPE THREAD Connect water supply to FAUCET 1 with 1 2 IPS FLEXIBLE SUPPLIES 2 or 3 8 O D BULL NOSE RISERS 3 Use adjustable wrench to tighten connections Do not over tighten Be careful not to kink copper supply when bending Use tubing cutter to cut to proper length Connect 1 1 4 O D t...

Страница 4: ... rotating side to side and remove SPOUT HANDLE 4 assembly to expose VALVES 7 Remove SPRING CLIP 5 from valve Lift STOP WASHER 6 turn 90 and replace Replace SPRING CLIP 5 Align SPOUT HANDLE 4 assembly and install onto valve body When handles and spout are properly seated and aligned tighten SET SCREWS 3 and replace PLUG BUTTONS 1 AERATOR 8 may accumulate dirt causing distorted and reduced water flo...

Страница 5: ... slowly Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode Fig A Fig B REMOVE CAM CAP REMOVE CAM Fig D Fig E Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A...

Страница 6: ...stic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the D...

Страница 7: ...d tools METAL OR PLASTIC TWO PIECE DRAIN BODY METAL DRAIN BODY WITH PLASTIC TAILPIECE PLASTIC DRAIN BODY WITH PLASTIC TAILPIECE UNTHREAD METAL FLANGE STOPPER WHEN DRAIN IS REMOVED FROM ABOVE SINK WHEN DRAIN IS REMOVED FROM BELOW SINK MOUNTING NUT MOUNTING NUT and GASKET METAL DRAIN BODY PLASTIC DRAIN BODY PLASTIC TAILPIECE P TRAP HALF PIVOT ROD NUT PIVOT ROD NUT SINK STOPPER SCREWDRIVER STOPPER MO...

Отзывы: