INSTALL POP-UP DRAIN
INSTALL BLACK GASKET
3
2
Install BLACK CONE GASKET
(1)
onto DRAIN BODY
(2)
from below.
Note:
The flat side of the BLACK CONE GASKET
(1)
must
face down.
4
Drop DRAIN BODY
(4)
through sink drain
hole. Make sure WHITE FOAM GASKET
(5)
is under flange of DRAIN BODY
(4)
.
Fig.
B.
Note:
No plumber’s putty or caulk is required.
The CABLE ATTACHMENT POINT
(6)
must
face towards the rear of the SINK.
Fig.
B.
Remove CLEAR PLASTIC COVER
(1)
. Remove
CARDBOARD SPACER
(2)
from under DRAIN
POP-UP
(3)
.
Fig.
A.
2
REAR OF
SINK
4
5
6
3
1
SINK
DRAIN
HOLE
Fig.
A.
2
1
FLAT SIDE OF
GRAY LOCKNUT
MUST FACE UP
INSTALL GRAY LOCKNUT
5
Install GRAY LOCKNUT
(1)
onto DRAIN BODY
(2)
from below SINK.
Fig.
A.
Note:
The flat side of the GRAY LOCKNUT
(1)
must face up.
Tighten firmly by hand. No tools are required.
Check DRAIN FLANGE in SINK to ensure that
WHITE FOAM GASKET
(3)
is fully compressed
and not visible.
Fig.
B.
POP-UP KNOB
(1)
must be fully down.
POP-UP KNOB
Fig.
A.
Fig.
B.
Certified to comply with ANSI A112.18.1
Installation
Instructions
Centerset Lavatory Faucet with the
Speed Connect™ Drain
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Helpful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
TIPS FOR REMOVING YOUR OLD DRAIN:
Loosen nuts on P-Trap using channel locks. Suggest spraying nuts with spray lubricant to loosen any corrosion or
debris that may have built up. Remove P-Trap half from Tailpiece. Use bucket to catch any residual water in P-trap.
Unthread Pivot Rod Nut from Drain Body and remove. Pull Stopper out from Drain Body.
Loosen Mounting Nut as far down as it will go. Push Drain Body up into Sink and unthread Metal Flange from Drain
Body. Remove Drain Body from below sink.
Unthread Tailpiece from Drain Body.
Loosen and remove Mounting Nut and Gasket on Drain Body using channel locks. Suggest spraying nut with spray
lubricant to loosen any corrosion or debris that may have built up. Push Drain Body up into the Sink and remove.
Note:
If Drain body rotates while loosening Mounting Nut, insert a screw driver into overflow hole to prevent Drain
Body from rotating while Mounting Nut is removed.
Adjustable Wrench
Phillips Screwdriver
Channel Locks
Recommended tools
METAL OR PLASTIC TWO PIECE
DRAIN BODY
METAL DRAIN BODY WITH
PLASTIC TAILPIECE
PLASTIC DRAIN BODY
WITH PLASTIC TAILPIECE
UNTHREAD
METAL
FLANGE
STOPPER
WHEN DRAIN IS REMOVED FROM ABOVE SINK
WHEN DRAIN IS REMOVED
FROM BELOW SINK
MOUNTING
NUT
MOUNTING
NUT and
GASKET
METAL
DRAIN
BODY
PLASTIC
DRAIN BODY
PLASTIC
TAILPIECE
P-TRAP
HALF
PIVOT
ROD NUT
PIVOT
ROD NUT
SINK
STOPPER
SCREWDRIVER
STOPPER
MOUNTING
NUT and
GASKET
METAL OR
PLASTIC
DRAIN BODY
FINISHED
WALL
FINISHED
WALL
FINISHED
WALL
PLASTIC
TAILPIECE
PIVOT
ROD NUT
SINK
SINK
P-TRAP
HALF
P-TRAP
HALF
Adjustable Wrench
Screwdriver
Channel Locks
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Recommended tools
Tubing Cutter
For Drains that are removed from below Sink:
For Drains that are removed from above Sink:
COMPRESSION
NUT
COUPLING
NUT
FLEXIBLE
SUPPLIES
3/8 O.D.
BULL-NOSE
RISERS
Thread CABLE CONNECTOR
(1)
clockwise
onto DRAIN BODY CONNECTION
(2)
and
hand tighten.
Fig.
A.
Your new POP-UP DRAIN installation is
now complete.
Fig.
B.
Note:
Tailpeice on pop-up drain is 1-1/4” O.D.
Fig.
B.
Fig.
A.
ATTACH CABLE CONNECTOR
6
2
1
Operate LIFT KNOB
(1)
to verify that STOPPER
(2)
opens and
closes.
Fig.
B.
Note:
If STOPPER
(2)
does not open and close properly then refer
to the “troubleshooting section” of these instructions.
CHECK OPERATION OF POP-UP
7
1-1/4” O.D.
Fig.
B.
1/2" PIPE
THREAD
Speed Connect™ Drain
Troubleshooting Guide
1
2
Disconnect the Cable from the Drain by threading the Cable Connector
(1)
counter-clockwise.
Fig.
A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled
as “Cam” and “Cam Cap” in the illustration.
Fig.
B.
Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain.
Fig.
D.
Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal.
Fig.
E.
The Stopper can now be removed by lifting it out of the Drain.
Fig.
F.
CAM
CAM CAP
RE-ATTACH
DISCONNECT
CABLE ADJUSTMENT PROCEDURE
If sink does not hold water even though Stopper is in the “down” position:
• Follow CABLE ADJUSTMENT PROCEDURE.
If Stopper does not raise up fully or sink drains too slowly
:
• Follow CABLE ADJUSTMENT PROCEDURE.
If you need to remove the Stopper:
• Follow STOPPER REMOVAL PROCEDURE.
If you would like the ability to remove your Stopper simply by lifting it out of the drain:
•
Follow STOPPER INSTALLATION PROCEDURE for
“Unlocked” mode
.
Fig.
A.
Fig.
B.
REMOVE
CAM CAP
REMOVE
CAM
Fig.
D.
Fig.
E.
Disconnect the Cable from the Drain by threading the Cable Connector
(1)
counter-clockwise.
Fig.
A.
Look at the area on the Drain Body where the Cable was attached and locate the component labeled as
“Cam” in the illustration.
Fig.
B.
Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go. At this point the
Stopper should be in the UP position.
Fig.
B, C.
Push DOWN on the Lift-Knob to make sure it is fully down.
Fig.
C.
Re-attach the Cable to the Drain Body Connection
(2)
by threading the Cable Connector
(1)
clockwise onto the
Drain Body Connection
(2)
and hand-tighten.
Fig.
A.
STOPPER REMOVAL PROCEDURE
STOPPER INSTALLATION PROCEDURE
Locked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper.
Fig.
G.
To install the stopper in
“Locked”
mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the
rear
of the
Sink and the American Standard logo is facing
front
. Rotate
Stopper slightly if necessary so that the Stopper slides all the
way down.
Fig.
G.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted.
Fig.
J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted.
Fig.
K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
Troubling Shooting Guide to complete installation. Stopper will be
in
“Locked”
mode and not be removable.
Unlocked Mode:
Look at the Plastic Loop at the bottom of the Stopper and notice
that the Loop is on one side of the Stopper.
Fig.
H.
To install the stopper in
“Unlocked”
mode, insert the Stopper into
the Drain so that the Plastic Loop is facing toward the
front
of the
Sink and the American Standard logo is facing
rear
. Rotate Stopper
slightly if necessary so that the Stopper slides all the way down.
Fig.
H.
Re-install the Cam into the Drain, rotating the Cam if necessary
to make sure it is fully inserted.
Fig.
J.
Re-install the Cam Cap, making sure the guide teeth are facing
outward. If the Cam Cap does not “snap” into place, then rotate
the Cam to make sure it is fully inserted.
Fig.
K.
Re-attach Cable. See “CABLE ADJUSTMENT PROCEDURE” in
“Troublingshooting Guide” to complete installation. Stopper will be
in
“Unlocked”
mode and removable.
Fig.
J.
Fig.
K.
INSTALL
CAM CAP
CAM
INSTALL CAM
The Stopper can be installed two ways, “Locked” Mode (Stopper cannot be
removed) or “Unlock” Mode (Stopper is removable).
1
INSTALL FAUCET
SINK OR
MOUNTING
SURFACE
POP-UP
CABLE
Turn off hot and cold water supplies before beginning.
Insert FAUCET
(1)
and CABLE CONNECTOR
(2)
through
mounting holes of Sink or mounting surface.
Fig.
A.
Assemble LOCKNUTS
(3)
onto SHANKS
(4)
( from under
side of Sink. Hand tighten firmly.
Fig.
B.
2
2
1
3
3
4
Turn off hot and cold water
supplies before beginning.
CAUTION
(HAND TIGHTEN)
3
WHITE FOAM
GASKET
NOT VISIBLE
DRAIN
FLANGE
Fig.
B.
LOOP TOWARD
REAR OF SINK
Fig.
G.
LOGO
DRAIN
Unlocked Mode
LOOP TOWARD
FRONT OF SINK
180˚
LOGO
DRAIN
Fig.
H.
Connect water supply to FAUCET
(1)
with 1/2" IPS FLEXIBLE
SUPPLIES
(2)
or 3/8" O.D. BULL-NOSE RISERS
(3)
.
Use adjustable wrench to tighten connections. Do not over tighten.
Be careful not to kink copper supply when bending. Use tubing
cutter to cut to proper length.
Connect 1-1/4” O.D. tailpiece on POP-UP DRAIN to
waste outlet.
MAKE WATER SUPPLY AND WASTE CONNECTIONS
8
FERRULE
1
2
3
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.
HOT
COLD
2
4
1
9
TEST INSTALLED FITTING
With HANDLES
(1)
in OFF position, turn on WATER
SUPPLIES
(2)
and check all connections for leaks.
Remove AERATOR
(3).
Turn counter-clockwise to remove.
Operate both HANDLES
(1)
to flush water lines thoroughly.
Replace AERATOR
(3)
. Turn clockwise to install.
5
1
2
3
CHECK DRAIN CONNECTIONS
Operate POP-UP KNOB
(4)
and fill lavatory with water.
Check that DRAIN STOPPER
(5)
makes a good seal
and retains water in SINK. If DRAIN STOPPER
(5)
does not seal properly, please refer to Troubleshooting
section in these instructions.
Release POP-UP KNOB
(5)
down and check all drain
connections and "P" trap for leaks. Tighten
if necessary.
11
“P” TRAP
WASTE
OUTLET
DOWN
UP
MODEL NUMBER
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1-800 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Product names listed herein are trademarks of American Standard Inc.
IN MEXICO 01-800-839-12-00
Fig.
C.
STOPPER
Fig.
F.
2
M962543-YYY0A
STOPPER
ASSEMBLY
M913208-0070A
SPONGE WASHER
M962551-0070A
CAM ASSEMBLY
M962431-0070A
DRAIN MOUNTING KIT
M952430-0070A
CABLE ASSEMBLY
M952410-YYY0A
DRAIN ASSEMBLY
Fig.
A.
Fig.
B.
3/8” COMPRESSION
CONNECTION
1
8
2
7
3
4
5
6
CLARIDGE
Remove PLUG BUTTONS
(1)
on either side of ESCUTCHEON
(2)
.
Loosen SET SEREWS
(3)
with 2.5mm hex wrench.
Pull SPOUT up while rotating side to side and remove
SPOUT & HANDLE
(4)
assembly to expose VALVES
(7)
.
Remove SPRING CLIP
(5)
from valve .
Lift STOP WASHER
(6)
, turn 90˚ and replace.
Replace SPRING CLIP
(5)
.
Align SPOUT & HANDLE
(4)
assembly and install onto valve body.
When handles and spout are properly seated and aligned tighten
SET SCREWS
(3)
and replace PLUG BUTTONS
(1)
.
AERATOR
(8)
may accumulate dirt causing distorted and reduced water flow.
Remove AERATOR
(8)
and rinse clean. Turn counter-clockwise to remove.
Turn HANDLES to OFF position.
Turn Hot and Cold supplies off to faucet.
To change direction of handle rotation, proceed as follows:
10
SERVICE
6054.XXX
Centerset Lavatory Faucet with
Speed Connect™ Drain
CLARIDGE
6054.XXX
M922881-YYY0A
AERATOR
M950219-YYY0A
LIFT ROD AND KNOB
M962670-YYY0A
HANDLE ASSEMBLY
065800-0070A
ATTACHMENT NUT
M910833-0070A
PUTTY PLATE
M 9 6 8 6 3 2
M 9 6 8 6 3 2
M 9 6 8 6 3 2
M 9 6 8 6 3 2
M 9 6 8 6 3 2
M 9 6 8 6 3 2
M 9 6 8 6 3 2
M 9 6 8 6 3 2
1
LIFT-
KNOB
994053-0070A
VALVE
M962671-0070A
BUTTON AND
SETSCREW
918049-0070A
ADAPTER
918555-0070A
HANDLE SCREW
5
6
90˚
4
7
1
3
If spout drips, operate handles several times from OFF to ON
position. Do not force - handles turn only 90˚.
Most existing drains can be removed quickly and easily with only a pair of channel-
lock pliers or a wrench. However, there may be situations where it is difficult to
remove your old drain or determine how the drain is disassembled. Depending upon
the existing Drain in your sink, it is either removed from above or below the sink.
The illustrations below show some typical drain installations and how they are disas-
sembled from the sink.
The following tips can help with some of the more common challenges in drain removal:
Congratulations on purchasing your American Standard faucet with
the Speed Connect Drain, a feature found only on
American Standard faucets.
Speed Connect Drain*
• 1/3 of the parts, installs in 1/3 of the time
• No tools needed
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
1
2
FLAT SIDE OF GASKET
MUST FACE DOWN
1
2
8
DOWN
Locked Mode
(Vandal Proof)
M923036-0070A
SNAP RING
© AS America, Inc. 2008
2.5mm
Hex wrench
CHROME
SATIN NICKEL
002
295
Replace the "YYY" with
appropriate finish code