INSTALL TOILET

a.  Position toilet squarely to wall and, with a rocking motion,
     press bowl down fully on wax ring and flange. Alternately
     tighten nuts until toilet is firmly seated on floor.

CAUTION: 

DO NOT OVERTIGHTEN NUTS

OR BASE MAY BE DAMAGED!

b.  Install caps on washers.  (If necessary, cut bolt height to
     size before installing caps.)  
c.  Smooth off the bead of sealant around base. Remove
     excess sealant.

!

INSTALL TOILET  SEAT 

Install toilet seat in accordance with manufacturer's directions.

If bowl fails to siphon, an 
adjustment may be required with 
the lift chain. Simply remove the 
bead chain from the retainment 
clip (see Fig. 9a) and take up 
slack on the chain, and reinsert 
on lift rod.  Make sure the chain 
is not too taut.

Before continuing, determine the type of water supply connection you have from 
the chart below and use the appropriate assembly parts required to properly 
reconnect the water supply. DO NOT use plumber's putty to seal these fittings.

CAUTION: DO NOT USE 
CONE WASHER WITH 
PLASTIC SUPPLY LINE.

These parts must be used as illustrated 
to insure water-tight connection. Use of 
existing coupling nut may result in water 
leakage. Water supply tube or pipe 
must extend at least 1/2" inside 
threaded shank of valve (does not apply 
to flanged tubing).

Use existing 
coupling nut 
and washer.

Use existing spiral cone 
washer. Fluidmaster cone 
washer may not seal 
completely on spiral type 
supply line.

Captive cone 
washers already 
included. No 
additional 
washers needed.

CAUTION: Overtightening of 
LOCK NUT or COUPLING 
NUT could result in breakage 
and potential flooding.

METAL/COPPER

FLARED TUBING

METAL FLANGED

TUBING

METAL SPIRAL

TUBING

VINYL/BRAIDED

CONNECTOR

LOCK NUT

LOCK NUT

LOCK NUT

LOCK NUT

COUPLING
NUT

COUPLING
NUT

EXISTING
COUPLING
NUT

COUPLING
NUT

WATER
SHUT-OFF

WATER
SHUT-OFF

WATER
SHUT-OFF

WATER
SHUT-OFF

CONE
WASHER

EXISTING
CONE
WASHER

EXISTING
WASHER

With correct washers in place (see Step 8a), 
tighten COUPLING NUT 1/4 turn beyond 
hand tight. 

DO NOT OVERTIGHTEN.

BOLTS

BOLT CAP

CLOSET FLANGE

Adjust water level to level 
indicated on tank by adjusting 
float cup. See Step 10.

CLOSET BOLT

NUT

WASHER

ADJUSTMENTS: 
Turn supply on.

a.

b.

6

7

8a

8b

9

10

Turn on water supply. 
Submerge the FLOAT 
CUP under the water for 
30 seconds. Adjust the 
water to desired level by 
turning WATER LEVEL 
ADJUSTMENT ROD 
and moving FLOAT 
CUP up or down.

TANK
LEVER

REFILL
TUBE

WATER LEVEL 

ADJUSTMENT 

ROD

TOP

ARM

NIPPLE

Diagram 1

PARTS FOR WATER
CONNECTION
(SEE STEP 8)

CONE WASHER

THREADED
SHANK

SHANK
WASHER

COUPLING NUT
(HAND TIGHT ONLY)

FLOAT

CUP

CRITICAL LEVEL

MARK ("C.L.")

MUST BE

1" ABOVE

OVERFLOW PIPE

LOCK NUT

Fig. 9a

VALVE

BODY

FILL 

VALVE

ADJUSTABLE
HEIGHT

!

WARNING:

 Do not use plumber’s putty, pipe dope, or any other sealant on the 

water supply connection to this tank. If the connection leaks after hand tightening, 
replace the supply line. If the connection continues to leak with the new supply line, 
replace the fill valve. 

Warranty is void if any type of sealant is used on the water 

supply connection.