background image

CENTRAL THERMOSTAT
WITH VOLUME CONTROL

Installation

Instructions

M 9 6 8 2 5 5 R e v . 1 . 1

R520

Thank you for selecting American-Standard...the benchmark

of fine quality for over 100 years.

To ensure that your installation proceeds smoothly--please

read these instructions carefully before you begin.

Certified to comply with ANSI A112.18.1M
ASSE 1016

ROUGHING-IN DIMENSIONS

CONNECTIONS ARE: 1/2" NPT

5-7/8

II

II

6-1/4

3-15/16

7

3-5/8

1-5/8 - 2-1/2

1/2" NPT
TUB

1/2" NPT
INLET

 1/2" NPT
INLET

TOP 

 1/2" NPT
SHOWER

IMPORTANT:

 

WHEN NOT USING A 

DIVERTER SPOUT A SEPARATE
DIVERTER VALVE MUST BE USED.

NOTE:

 

MINIMUM FLOWING PRESSURE REQUIRED FOR

THIS SYSTEM OPERATING WITH ONE SHOWER HEAD
AND 2 BODY SPRAYS IS 40 PSI

TUB PORT MUST
BE PLUGGED

HOT

1/2"

1/2"

COLD

TUB PORT MUST
BE PLUGGED

HOT

1/2"

1/2"

COLD

THERMOSTATIC BATH/

SHOWER INSTALLATION

USING A TWIN ELL, DIVERTER

SPOUT AND FIXED SHOWER 

THERMOSTATIC SHOWER INSTALLATION

USING A DIVERTER VALVE, FIXED

SHOWER HEAD AND ADJUSTABLE HAND

HELD SHOWER  

THERMOSTATIC SHOWER INSTALLATION USING A

DIVERTER VALVE, FIXED SHOWER HEAD, ADJUSTABLE

HAND HELD SHOWER, ON/OFF VALVE AND TWO

BODY SPRAYS  

TWIN

ELL

TOP OF TUB RIM
BOTTOM OF TUB

TUB PORT

MUST BE

PLUGGED

DIVERTER

VALVE

DIVERTER

VALVE

ON/OFF

VALVE

C/L

4"

18"

(OPTIONAL)

80"-86"

Содержание Ceratherm T050.210

Страница 1: ...s cleaners Non acidic non abrasive gentle liquid or fully dissolved powder cleansers mixed according to manufacturers directions Non abrasive liquid polishers Once clean rinse faucet again with clear...

Страница 2: ...tach with 60mm SCREWS 6 to valve body 1 0 0 If a temperature over 100 F is desired pull the RED STOP BUTTON 1 away from the body of the MIXER UNIT and turn the TEMPERATURE KNOB If the system is delive...

Страница 3: ...EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2003 918416 0070A TEMPERATURE SCREW 909750 YYY0A HANDLE RING 918428 0070A VOLUME CONTROL SCREW 907065 YYY0...

Страница 4: ...A DIVERTER SPOUT A SEPARATE DIVERTER VALVE MUST BE USED NOTE MINIMUM FLOWING PRESSURE REQUIRED FOR THIS SYSTEM OPERATING WITH ONE SHOWER HEAD AND 2 BODY SPRAYS IS 40 PSI TUB PORT MUST BE PLUGGED HOT...

Страница 5: ...move the TEMPERATURE LIMIT STOP H shaped Black Plastic part Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F Reinstall RED L...

Страница 6: ...Weekdays 8 00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2003 923348 0070A HANDLE ADAPTER 994053 0070A CARTRIDGE 953960 0070A THERMO...

Страница 7: ...SEPARATE DIVERTER VALVE MUST BE USED NOTE MINIMUM FLOWING PRESSURE REQUIRED FOR THIS SYSTEM OPERATING WITH ONE SHOWER HEAD AND 2 BODY SPRAYS IS 40 PSI TUB PORT MUST BE PLUGGED HOT 3 4 3 4 COLD TUB POR...

Страница 8: ...e TEMPERATURE LIMIT STOP H shaped Black Plastic part Reinstall it at the desired notch as indicated in the diagram to limit the maximum mixed water temperature to 104 F or 112 F Reinstall RED LOCKING...

Страница 9: ...00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2003 923348 0070A HANDLE ADAPTER A994352 0070A CARTRIDGE 954040 0070A THERMOSTAT CARTRI...

Отзывы: