![American Standard Cadet 5' x 36](http://html1.mh-extra.com/html/american-standard/cadet-5-x-36/cadet-5-x-36_specification-sheet_2926288002.webp)
H62
© 2008 AS America Inc.
CADET™ 5' x 36"
WHIRLPOOL AND BATHING POOL
HIGH GLOSS
Revised 2/08
RECOMMENDED FITTING LOCATION
64 X 330mm (2-1/2 x 13")
FOR PIER OR ISLAND
INSTALLATIONS ONLY
ALT. FITTING
LOCATION #1
464 mm
(18-1/4)
38 mm
(1-1/2)
502 mm
(19-3/4)
1-1/2 O.D.TAILPIECE
LEVELING
STRINGER
NOT FOR
SUPPORT
SAFE-T-HEATER
REMOVABLE
BLANK
ROUGH
FLOOR
1524 mm
(60)
914 mm
(36)
OUTLINE OF CUTOUT
1486 mm x 876 mm
(58-1/2 X 34-1/2)
457 mm
(18)
235 mm
(9-1/4)
305 mm
(12)
57 mm
(2-1/4)
(8) JETS
76 mm
(3)
CUTOUT IN FLOOR
FOR DRAIN
PUMP
FINISHED
WALL
305 mm
(12)
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
1651 & 1981mm
(65 & 78)
C/L OF
OVERFLOW
102 mm
(4)
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
70 mm
(2-3/4)
117 mm
(4-5/8)
1-1/2 N.P.T.M.
THREADS
19 mm
(3/4)
229 mm
(9)
C/L OF
SUPPLIES
C/L OF DRAIN
SEE FITTING
SPECS FOR
DIMENSIONS
(2) AIR VALVES
ON/OFF
SWITCH
PROVIDE ACCESS TO PUMP FOR
SERVICING ON ALL INSTALLATIONS
INTEGRAL
SUPPORT
FEET
RECOMMENDED FITTING LOCATION
64 X 330mm (2-1/2 x 13")
FOR PIER OR ISLAND
INSTALLATIONS ONLY
ALT. FITTING
LOCATION #1
ALT. FITTING
LOCATION #2
64 x 330mm
(2-1/2 x 13")
OUTLINE OF CUTOUT
1486 mm x 876 mm
(58-1/2 X 34-1/2)
464 mm
(18-1/4)
38 mm
(1-1/2)
502 mm
(19-3/4)
1-1/2 O.D.TAILPIECE
INTEGRAL
SUPPORT
FEET
LEVELING STRINGER
NOT FOR SUPPORT
ROUGH
FLOOR
1524 mm
(60)
914 mm
(36)
457 mm
(18)
235 mm
(9-1/4)
305 mm
(12)
57 mm
(2-1/4)
67 mm
(2-5/8)
CUTOUT IN FLOOR
FOR DRAIN
FINISHED
WALL
305 mm
(12)
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
1651 & 1981mm
(65 & 78)
C/L OF
OVERFLOW
102 mm
(4)
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
70 mm
(2-3/4)
117 mm
(4-5/8)
1-1/2 N.P.T.M.
THREADS
19 mm
(3/4)
229 mm
(9)
C/L OF
SUPPLIES
C/L OF DRAIN
SEE FITTING
SPECS FOR
DIMENSIONS
60 x 36 x 19-3/4 In.(1524 x 914 x 502mm)
95 Lbs. (43 Kg.)
587 Lbs. (267 Kg.)
59 Gal. (224 L.)
48 Gal. (182 L.)
40 x 22 In. (1016 x 559mm)
52 x 29 In. (1321 x 737mm)
13-1/4 In. (337mm)
39 Lbs./Sq. Ft. (188 Kgs/Sq. m.)
23.8
44.5
GENERAL SPECIFICATIONS FOR 2771 WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
1.6 HP, 9.7 AMPS, 120V.
SYSTEM I PUMP
60 x 36 x 19-3/4 In.
(1524mm x 914 mm x 502mm)
70 Lbs. (32 Kg.)
562 Lbs. (255 Kg)
59 Gal. (224 L.)
40 x 22 In. (1016mm x 559mm)
52 x 29 In. (1321mm x 737mm)
13-1/4 In. (337mm)
37 LBS./Sq. Ft. (180 Kgs/Sq. m.)
23.8
44.5
GENERAL SPECIFICATIONS FOR 2771 BATHING POOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)
NOTES:
BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUMP OF
BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.
■
REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.
OPTIONAL 3 WALL TILING BEAD. KIT AND APRON NO. 9260.018 OR 9360.018 AVAILABLE AND MUST BE ORDERED SEPARATELY.
●
FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.
PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.
●
IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES: CHECK FOR INTERFERENCE WITH CIRCULATING
SYSTEM PIPING, DRAIN OVERFLOW, AND APRON INSTALLATION. MOUNTING HOLES DRILLED BY INSTALLER.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1
These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaflet.