American Standard Cadet 5' x 36

H62

© 2008 AS America Inc.

CADET™ 5' x 36"

WHIRLPOOL AND BATHING POOL

HIGH GLOSS

Revised 2/08

RECOMMENDED FITTING LOCATION

64 X 330mm (2-1/2 x 13")

FOR PIER OR ISLAND

INSTALLATIONS ONLY

ALT. FITTING

LOCATION #1

464 mm
(18-1/4)

38 mm

(1-1/2)

502 mm
(19-3/4)

1-1/2 O.D.TAILPIECE

LEVELING

STRINGER

NOT FOR

SUPPORT 

SAFE-T-HEATER
REMOVABLE
BLANK

ROUGH

FLOOR

1524 mm

(60)

914 mm

(36)

OUTLINE OF CUTOUT 
1486 mm x 876 mm
(58-1/2 X 34-1/2)

457 mm

(18)

235 mm

(9-1/4)

305 mm

(12)

57 mm
(2-1/4)

(8) JETS

76 mm

(3)

CUTOUT IN FLOOR
FOR DRAIN

PUMP

FINISHED

WALL

305 mm

(12)

OPTIONAL TO 

FINISHED FLOOR 

USUALLY BETWEEN

1651 & 1981mm 

(65 & 78)

C/L OF
OVERFLOW

102 mm

(4)

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
SHOWER ARM

70 mm

(2-3/4)

 117 mm

(4-5/8)

1-1/2 N.P.T.M.

THREADS

19 mm

(3/4)

229 mm

(9)

C/L OF

SUPPLIES

C/L OF DRAIN

SEE FITTING

SPECS FOR

DIMENSIONS

(2) AIR VALVES

ON/OFF
SWITCH

PROVIDE ACCESS TO PUMP FOR

SERVICING ON ALL INSTALLATIONS

INTEGRAL

SUPPORT

FEET

RECOMMENDED FITTING LOCATION

64 X 330mm (2-1/2 x 13")

FOR PIER OR ISLAND

INSTALLATIONS ONLY

ALT. FITTING

LOCATION #1

ALT. FITTING

LOCATION #2

64 x 330mm

(2-1/2 x 13")

OUTLINE OF CUTOUT 
1486 mm x 876 mm
(58-1/2 X 34-1/2)

464 mm
(18-1/4)

38 mm

(1-1/2)

502 mm
(19-3/4)

1-1/2 O.D.TAILPIECE

INTEGRAL

SUPPORT

FEET

LEVELING STRINGER

NOT FOR SUPPORT 

ROUGH

FLOOR

1524 mm

(60)

914 mm

(36)

457 mm

(18)

235 mm

(9-1/4)

305 mm

(12)

57 mm
(2-1/4)

67 mm
(2-5/8)

CUTOUT IN FLOOR
FOR DRAIN

FINISHED

WALL

305 mm

(12)

OPTIONAL TO 

FINISHED FLOOR 

USUALLY BETWEEN

1651 & 1981mm 

(65 & 78)

C/L OF
OVERFLOW

102 mm

(4)

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
SHOWER ARM

70 mm

(2-3/4)

 117 mm

(4-5/8)

1-1/2 N.P.T.M.

THREADS

19 mm

(3/4)

229 mm

(9)

C/L OF

SUPPLIES

C/L OF DRAIN

SEE FITTING

SPECS FOR

DIMENSIONS

  60 x 36 x 19-3/4 In.(1524 x 914 x 502mm)

95 Lbs. (43 Kg.)

587 Lbs. (267 Kg.)

59 Gal. (224 L.)
48 Gal. (182 L.)

40 x 22 In. (1016 x 559mm)
52 x 29 In. (1321 x 737mm)

13-1/4 In. (337mm)

39 Lbs./Sq. Ft. (188 Kgs/Sq. m.)

23.8
44.5

GENERAL SPECIFICATIONS FOR 2771 WHIRLPOOL

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

WHIRLPOOL ELECTRICAL SPECIFICATIONS

1.6 HP, 9.7 AMPS, 120V.

SYSTEM I PUMP

 

60 x 36 x 19-3/4 In.

(1524mm x 914 mm x 502mm)

70 Lbs. (32 Kg.)

562 Lbs. (255 Kg)

59 Gal. (224 L.)

40 x 22 In. (1016mm x 559mm)
52 x 29 In. (1321mm x 737mm)

13-1/4 In. (337mm)

37 LBS./Sq. Ft. (180 Kgs/Sq. m.)

23.8
44.5

GENERAL SPECIFICATIONS FOR 2771 BATHING POOL

INSTALLED SIZE

WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

NOTES:

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA TYPE INSTALLATION. SUMP OF 

BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT REQUIRED. ENCLOSING MATERIAL BY OTHERS.

■ 

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL INFORMATION.

OPTIONAL 3 WALL TILING BEAD. KIT AND APRON NO. 9260.018 OR 9360.018 AVAILABLE AND MUST BE ORDERED SEPARATELY.

● 

FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.

● 

IF INSTALLING A DECK-MOUNTED FITTING, BEFORE DRILLING ANY HOLES:  CHECK FOR INTERFERENCE WITH CIRCULATING 

SYSTEM PIPING, DRAIN OVERFLOW, AND APRON INSTALLATION.  MOUNTING HOLES DRILLED BY INSTALLER.

IMPORTANT: Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI Standard Z124.1

These measurements are subject to change or cancellation. No responsibility is assumed for use of superseded or voided leaflet.