American Standard Cadet 2772.002 Скачать руководство пользователя страница 2

CADET™ 5’ X 42”

WHIRLPOOL & BATHING POOL

HIGH GLOSS ACRYLIC

© 2003 American Standard Inc.

OUTLINE OF CUTOUT 
1486mm x 1029mm
(58-1/2 X 40-1/2)

RECOMMENDED FITTING LOCATION

76 X 330mm (3 x 13")

FOR PIER OR ISLAND

INSTALLATIONS ONLY

ALT. FITTING LOCATION

464 mm
(18-1/4)

38 mm

(1-1/2)

502 mm
(19-3/4)

1-1/2 O.D.TAILPIECE

■ 

LEVELING

STRINGER

NOT FOR

SUPPORT 

ROUGH

FLOOR

1524mm

(60)

1067mm

(42)

533mm

(21)

235 mm

(9-1/4)

305 mm

(12)

57 mm
(2-1/4)

(8) JETS

76mm

(3)

CUTOUT IN FLOOR
FOR DRAIN

PUMP

FINISHED

WALL

305mm

(12)

OPTIONAL TO 

FINISHED FLOOR 

USUALLY BETWEEN

1651 & 1981mm 

(65 & 78)

C/L OF
OVERFLOW

102 mm

(4)

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
SHOWER ARM

70 mm

(2-3/4)

 117 mm

(4-5/8)

1-1/2 N.P.T.M.

THREADS

19 mm

(3/4)

229 mm

(9)

C/L OF

SUPPLIES

C/L OF DRAIN

SEE FITTING

SPECS FOR

DIMENSIONS

(2) AIR VALVES

ON/OFF
SWITCH

PROVIDE ACCESS TO PUMP FOR

SERVICING ON ALL INSTALLATIONS

INTEGRAL

SUPPORT

FEET

SAFE-T-HEATER
REMOVABLE
BLANK

OUTLINE OF CUTOUT 
1473 mm x 1016mm
(58 X 40)

RECOMMENDED FITTING LOCATION

76 X 330mm (3 x 13")

FOR PIER OR ISLAND

INSTALLATIONS ONLY

ALT. FITTING LOCATION

464 mm
(18-1/4)

38 mm

(1-1/2)

502 mm
(19-3/4)

1-1/2 O.D.TAILPIECE

INTEGRAL

SUPPORT

FEET

■ 

LEVELING STRINGER

NOT FOR SUPPORT 

ROUGH

FLOOR

1524 mm

(60)

1067 mm

(42)

527 mm
(20-3/4)

250 mm

(9-3/4)

305 mm

(12)

57 mm
(2-1/4)

89 mm
(3-1/2)

CUTOUT IN FLOOR
FOR DRAIN

FINISHED

WALL

305 mm

(12)

OPTIONAL TO 

FINISHED FLOOR 

USUALLY BETWEEN

1651 & 1981mm 

(65 & 78)

C/L OF
OVERFLOW

102 mm

(4)

C/L OF
SPOUT

C/L OF
VALVES

C/L OF
SHOWER ARM

70 mm

(2-3/4)

 117 mm

(4-5/8)

1-1/2 N.P.T.M.

THREADS

19 mm

(3/4)

229 mm

(9)

C/L OF

SUPPLIES

C/L OF DRAIN

SEE FITTING

SPECS FOR

DIMENSIONS

  60 x 42 x 19-3/4 In.(1524 x 1067 x 502mm)

117 Lbs. (53 Kg.)

642 Lbs. (289 Kg.)

63 Gal. 239 L.)

54 Gal. (204 L.)

40 x 26 In. (1016 x 660 mm)

52 x 32-1/2 In. 1321 x 826 mm)

13-1/4 In. (337 mm)

37 Lbs./Sq. Ft. (182 Kgs/Sq. m.)

27.8
45.4

GENERAL SPECIFICATIONS FOR 2772 WHIRLPOOL

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

WHIRLPOOL ELECTRICAL SPECIFICATIONS

1.6 HP, 9.7 AMPS, 120V.

SYSTEM I PUMP

  60 x 42 x 19-3/4 In.

(1524mm x 1067mm x 502mm)

92 Lbs. (41 Kg.)

617 Lbs. (278 Kg.)

63 Gal. (239 L.)

40 x 26 In. (1016 x 660 mm)

52 x 32-1/2 In. 1321 x 826 mm)

13-1/4 In. (337 mm)

36 Lbs./Sq. Ft. (175 Kgs/Sq. m.)

27.8
45.4

GENERAL SPECIFICATIONS FOR 2772 BATHING POOL

INSTALLED SIZE

WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

NOTES:

BATH CAN BE INSTALLED EITHER ABOVE OR BELOW FLOOR LINE AS PIER, ISLAND, OR PENINSULA
TYPE INSTALLATION. SUMP OF BATH IS SUPPORTED BY INTEGRAL FEET. NO ADDITIONAL SUPPORT
REQUIRED. ENCLOSING MATERIAL BY OTHERS.

REFER TO INSTALLATION INSTRUCTIONS SUPPLIED WITH WHIRLPOOL FOR ADDITIONAL
INFORMATION.

OPTIONAL 3 WALL TILING BEAD. KIT AND APRON No. 9260.018 or 9360.018 AVAILABLE AND MUST BE
ORDERED SEPARATELY.

FITTINGS NOT INCLUDED AND MUST BE ORDERED SEPARATELY.

PROVIDE SUITABLE REINFORCEMENT FOR ALL SUPPORTS.

IMPORTANT:

Dimensions of fixtures are nominal and may vary within the range of tolerances established by ANSI
Standard Z124.1
These measurements are subject to change or cancellation. No responsibility is assumed for use of
superseded or voided leaflet.

Отзывы: