DECK MOUNT BATH FILLER
BERWICK
™
/ BOULEVARD
™
Certified to comply with ANSI A112.18.1M
Installation
Instructions
7430.9XX
7431.9XX
Thank you for selecting American-Standard...
the benchmark of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--
please read these instructions carefully before you begin.
Recommended Tools
*Supplied with Fitting
*Hex key
SPOUT BASE RECESS
Turn off hot and cold water
supplies before beginning.
CAUTION
1
2
Assemble RUBBER WASHER
(4)
and BRASS WASHER
(5)
and
LOCKNUT
(6)
onto SPOUT SHANK
(3)
. Align SPOUT ASSEMBLY
and from underside of ledge secure SPOUT ASSEMBLY into
position with LOCKNUT
(6)
.
SPOUT ASSEMBLY
PREPARE TUBE AND TEE ASSEMBLY
4
2
3
1
3
4
1
2
4
5
Prepare TUBE and TEE ASSEMBLY
(1)
to fit center to center
VALVE (2) location
(between 6-1/2" and 12")
. If necessary,
cut and/or bend TUBING carefully. Make sure tube bend is
close to the TEE
(1)
so that it will not effect the compression
joint at the VALVE CONNECTION.
ADJ. 6-1/2 TO 12
6
5
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
MOUNTING
SURFACE
VALVE inlet is 3/4-inch NPT male.
NOTE
ROUGHING-IN DIMENSIONS
MOUNTING
SURFACE
Install RING WASHER
(1)
into spout base recess. Check that
O-RING
(2)
on end of SPOUT SHANK
(3)
is in place. Insert SPOUT
SHANK
(3)
through center hole on mounting surface.
3
Remove COUPLING NUT
(3)
and FERRULE
(4)
from each
VALVE
(2)
and slide onto TUBING
(5)
.
SPOUT
ASSEMBLY
70mm
(2-3/4")
152-305mm
(6"-8")
57mm
(2-1/4")
108mm
(4-1/4")
52mm
(2")
170mm
(6-3/4")
286mm
(11-1/4")
212mm
(8-3/8")
1-1/2 MAX.
(38mm) MAX.
1-3/16" MAX.
(30mm) MAX.
1-3/16 D.
(30mm) D.
3'
(76mm)
(H)
(C)
1-1/8 D.
12 MAX.
(305mm)
1-1/16 D.
(27mm) D.
3/4-14 MALE
N.P.T. INLETS
M968644 REV.1.4 (10/16)