6
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
1
6
4
5
7
5
TEST INSTALLED FAUCET
Move HANDLE
(1)
down into "off" position.
With HANDLE
(1)
down in "off" position, pull HAND SPRAY
(3)
from SPOUT
(4).
SPRAY (HOSE
(5)
should pull approximately 2 feet
and direct open SPRAY END
(3)
into sink.
Operate handle up and down, in COLD and HOT positions,
to flush water lines thoroughly.
Replace AERATOR
(2)
. Place HAND SPRAY
(3)
back into FAUCET
(4)
.
Check HAND SPRAY
(3)
operation:
With faucet on push BUTTON
(6)
for a broad cleansing
spray. BUTTON
(6)
will lock into this position.
If faucet drips, operate HANDLE several times from "off" to "on." Do not
apply excessive force.
Remove INDEX BUTTON
(1)
, loosen HANDLE SCREW
(2)
and remove HANDLE
(3)
.
Unthread ESCUTCHEON CAP
(4)
. Unthread three
MOUNTING SCREWS
(5)
.
Lift CARTRIDGE
(6)
off MANIFOLD
(7)
and remove
CARTRIDGE SEALS
(8)
.
Place SEALS
(8)
into CARTRIDGE PORTS
(6a)
.
Replace ESCUTCHEON CAP
(4)
, HANDLE
(3)
, tighten HANDLE
SCREW
(1)
and install INDEX BUTTON
(2)
.
Test fitting.
Clean MANIFOLD
(7)
, CARTRIDGE
(6)
ports and SEALS
(8)
.
Place CARTRIDGE
(6)
onto MANIFOLD
(7)
and tighten MOUNTING
SCREWS
(5)
alternately.
Remove AERATOR
(2)
.
To unlock push opposite end of BUTTON
(6)
. Faucet will
return to standard spray.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
2
3
1
2
3
4
5
6
8
7
6a