background image

- 1 -

CEAS5017-0110400T0 (305mm Hole distance)

Installation Manual

Aerozen G2 Integrated Shower Toilet

Installation Manual of Shower Toilet

Please strictly observe for your safety!

To avoid accidents during use, please follow the precautions. Install the warm water 

cleaning shower toilet safely. 

Read the precautions before installation, and then install correctly to avoid accidents.

Description of Terms

WARNING

WARNING

CAUTION

CAUTION

Improper use of the product could lead to death or major injury.

Improper use of the product could lead to minor injury or property damage.

Never disassemble, repair or modify the product if you are not a professional servicing technician.

Risk of electric shock and fire, or injury to users due to incorrect activation of the product.

Ensure that the integrated shower toilet and the inside/outside of the remote controller and the 

power plug are protected against splash of liquid such as water or detergent.

Risk of electric shock or fire.

Be sure to connect grounding wire.

Risk of electric shock in case of malfunction or electric leakage.

If no grounding terminal is found on the socket, please consult with the electrical installation company.

Do not place the integrated shower toilet and the remote controller in a wet place subject to 

splashing water.

Otherwise, it may lead to electric shock or fire.

Do not plug or unplug the power plug with wet hand.

Risk of electric shock.

Do not use power supply other than AC 220V.

Otherwise, it may lead to electric shock or fire.

Be sure to fasten the water supply hose securely.

Risk of water leakage due to loosely tightened nut.

Be sure to adjust the water supply angle valve and check for water leakage after installation.

Risk of wetting the household property in case of water leakage.

Please remove all water to prevent freezing before the product is delivered to the customer.

Risk of wetting the household property in case of water leakage due to freezing damage.

Do not insert the power plug into the power socket before the installation is completed.

Risk of water leakage in case of a burnout.

When removing the filter, water supply angle valve must be turned off. When installing the filter, 

please tighten it properly without leaving any gap.

Risk of water leakage of filter.

Do not damage the power cord and make it broken; do not modify, fold, extend, curl or twine 

the cord by force, or excessively press the cord by placing heavy stuff on top of the cord.

Risk of electric shock or fire due to damage of the power cord.

The water supply hose must be connected to the running water. If the built-in filter gets clogged 

easily with the dirt and fine particles in the pipe, install a filter unit connected to the running water.

Cystitis or dermatitis may be caused, or electric shock and fire may be caused due to internal corrosion 
of machinery.

Do not use damaged power plug and loosened power socket.

Otherwise, it may lead to electric shock or fire.

Be sure to install electric leakage protector.

Risk of electric shock in case of malfunction or electric leakage.

If no electric leakage protector is found, please consult with the electrical installation company.

Содержание Aerozen G2

Страница 1: ... may lead to electric shock or fire Be sure to fasten the water supply hose securely Risk of water leakage due to loosely tightened nut Be sure to adjust the water supply angle valve and check for water leakage after installation Risk of wetting the household property in case of water leakage Please remove all water to prevent freezing before the product is delivered to the customer Risk of wettin...

Страница 2: ... on the left wall Sensor window When the remote controller is installed on the right wall Water supplied must be connected to running water If heavy water industrial water well water etc are used it may reduce durability of electrical and mechanical components resulting in malfunction The minimum working water pressure is above 0 06 MPa dynamic flow and the highest static water pressure is 0 75 MP...

Страница 3: ... 15 5 Finished wall 250 Note This dimensional drawing is for reference only and the specific dimensions of the product may vary within tolerances Water supply angle valve The connection dimension of water supply angle valve is 1 2 inch of straight thread Blow down pipe When installing a standard pipe with an inner diameter of 102mm make sure that the horizontal blow down pipe must be installed at ...

Страница 4: ...le B Place the toilet on the ground and mark along the bottom edge of the toilet and the ground mounting hole The outer contour line marked in Figure B is for reference only Use a drill 10mm in diameter to punch a mounting hole at the marked ground position as per the dimensions shown in the figure and pre embed the expansion bolt The image shown here is only for reference The actual product may d...

Страница 5: ...o prevent it from falling off during installation After the strip is stuck soak a piece of cloth and wring the water out Use the cloth to scrub the strip in two circles until the surface becomes non viscous temporarily Lift the toilet and put it in place by aligning its sewage outlet to the pre installed plastic sewage elbow following the mark on the ground Connect the water supply hose to the wat...

Страница 6: ...crew Alkaline dry battery Back cover When loading the battery do not connect the positive and negative terminal reversely Do not mix the old battery with the new one Be sure to turn on the power after the E bidet is installed When the power indicator is not on press the restart button to confirm whether the power light is on Do not plug in while sitting on the toilet seat This may render the nozzl...

Страница 7: ...The screwing is very difficult at first becomes easier gradually and finally difficult again 2 Align the remote controller with the bracket from the top and press it down to the specified position 1 Fully open the switch wrench of the water supply angle valve and supply water to the toilet 1 Confirmation of posterior and feminine 1 Stick your arm to the sitting sensor 2 Press Posterior button 3 Af...

Страница 8: ...cording to signal table in the following figure press corresponding button while installing batteries and hold for 6 seconds 20s for Feminine or Posterior 3 When transmission signal changes battery indicator of remote controller will flash accordingly Flashing times of battery indicator vary with the corresponding signal change 2 Change of signal received by the E bidet 1 Temporarily unplug the po...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ...engatan listrik atau kebakaran Yakinlah anda telah mengencangkan selang aliran air dengan benar Resiko kebocoran air karena mur yang longgar Yakinlah anda telah menyesuaikan katup penghenti aliran air dan periksalah akan adanya kebocoran air setelah instalasi Resiko basahnya properti di dalam rumah dalam hal terjadi kebocoran air Harap kosongkan semua air untuk mencegah pembekuan sebelum produk di...

Страница 18: ...ri Jendela sensor Pada saat pengendali jarak jauh dipasang pada dinding kanan Air yang disediakan harus terhubung pada air yang mengalir Jika yang digunakan adalah air berat air industrial air sumur atau lainnya hal ini dapat mengurangi durabilitas dari komponen elektrik dan mekanikal yang dapat berakibat pada terjadinya malfungsi Tekanan air bekerja minimum adalah di atas 0 06 Mpa aliran dinamis ...

Страница 19: ...Dinding yang telah selesai 250 Catatan Gambar dimensional ini adalah untuk acuan semata dan dimensi spesifik dari produk dapat bervariasi di dalam batas toleransi Katup penghenti aliran air Dimensi sambungan dari katup penghenti aliran air adalah inci dari benang lurus Pipa peniupan ke bawah blow down Pada saat memasang pipa standar dengan diameter dalam sepanjang 102 mm pastikanlah bahwa pipa pen...

Страница 20: ...i tanah dan tandai di sepanjang tepian dasar dari toilet dan lubang pemasangan Garis kontur luar yang ditandai dalam Figur B hanya untuk acuan semata Gunakan bor dengan diameter 10 mm untuk melubangi lubang pemasangan di posisi tanah yang telah ditandai sesuai dengan diameter yang ditunjukkan dalam figur dan pasanglah lebih dahulu baut perluasan Gambar yang ditunjukkan di sini hanya untuk acuan se...

Страница 21: ...dak jatuh selama instalasi Setelah pita perekat melekat basahilah sepotong kain dan peraslah airnya Gunakan kain tersebut untuk menggosok pita perekat dengan ara dua lingkaran sampai permukaan menjadi tidak bersifat kental viskous untuk sementara waktu Pasanglah toilet di tempatnya Angkatlah toilet dan letakkan di tempatnya dengan menyejajarkan outlet pembuangannya ke siku pembuangan plastik yang ...

Страница 22: ...n bahwa anda menyalakan tenaga listrik setelah E bidet dipasang Pada saat indikator tenaga listrik tidak menyala tekanlah tombol mulai kembali restart untuk memastikan apakah lampu tenaga listrik menyala Jangan mencolokkannya pada saat duduk di toilet Hal ini dapat menjadikan penyemprot Posterior Feminin tidak dapat memancurkan air Pada saat penyemprot tidak dapat memancurkan air colokkan lagi tan...

Страница 23: ...ada awalnya sangat sulit kemudian menjadi lebih mudah secara bertahap kemudian pada akhirnya menjadi sulit kembali 2 Sejajarkan pengendali jarak jauh dengan braket dari atas dan tekanlah ke bawah ke posisi yang telah ditentukan 1 Bukalah sepenuhnya kran dari katup penghenti aliran air dan alirkanlah air ke toilet 1 Konfirmasi posterior dan feminin 1 Letakkan tangan anda di sensor dudukan 2 Tekanla...

Страница 24: ...i dan tahan selama 6 detik 20 detik untuk Feminin atau Posterior Pada saat transmisi signal berubah indikator baterai dari pengendali jarak jauh akan berkedip sesuai dengan perubahan tersebut Waktu kedip dari indikator baterai bervariasi sesuai dengan perubahan signal yang terjadi 2 1 2 Perubahan signal yang diterima oleh E bidet Sementara cabutlah steker tenaga listrik dari dudukan yang perlu diu...