background image

3

  7301793-100 Rev. C

4

5

6

INSTALL ICU SINK

1. Mount SINK onto the two HANGER STUDS. Hold SINK in place 

and temporarily install NYLOCK NUT & WASHER on one of the 

HANGER STUDS to retain SINK.

MOUNT ELECTRONICS BOX 

COMPLETE WASTE OUTLET CONNECTION

NOTE: Installation with ELECTRONIC BOX only is for cold 

or tempered water. Use optional MIXING VALVE with 

ELECTRONIC BOX when Hot and Cold supplies are 

roughed-in. See illustration below.

8

INSTALL ELECTRONICS HANGER BRACKET

1. Install the ELECTRONICS HANGER BRACKET onto remaining 

HANGER STUD. Install NYLOCK NUT & WASHER but do not 

tighten fully.

2. Remove NYLOCK NUT & WASHER from first HANGER STUD 

and install other end of ELECTRONICS HANGER BRACKET. 

Replace NYLOCK NUT & WASHER, tighten both ends. Do not over 

tighten, chinaware could become damaged.   

NYLOCK NUT

AND WASHER

HANGER STUD

COLD WATER OR

TEMPERED WATER

(3/8" SUPPLY)

HOT

MIXING VALVE

MIXING VALVE

SCREWS

MOUNTING PLATE

ELECTRONIC

BOX

ELECTRONIC BOX

COLD

1

2

1.  Connect SUPPLY NUT (1)  from SPOUT assembly to nipple on 

top of ENCLOSURE (2). Tighten with adjustable wrench to make a 

water tight connection.

CONNECT SPOUT HOSE TO ENCLOSURE

 

ELECTRONIC

BOX

1. Install “P” TRAP. Connect OFFSET TAILPIECE to “P” TRAP. 

TAILPIECE may have to be cut to fit installation. Use tubing cutter to 

cut TAILPIECE.

P-TRAP

TAILPIECE

1-1/4" OD

1-1/4" or 1-1/2" OD

WASTE OUTLET

ELECTRONICS

HANGER BRACKET

7

1. Remove COVER from ELECTRONICS BOX.

2. Place ELECTRONICS BOX onto MOUNTING PLATE. Align 

BOX with mounting holes. Attach with SCREWS provided.

3. Hang MOUNTING PLATE with ELECTRICAL BOX on 

HANGER BRACKET.

Содержание 9118.111

Страница 1: ... INSTALLATION INSTRUCTIONS Pr o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A S A m e r i c a I n c A S A m e r i c a I n c 2 01 2 14 3 4 375mm 17 432mm 4 3 4 121mm 5 8 14mm 1 5 8 41mm 20 509mm 4 3 4 120mm 8 203mm 1 2 DIA 13mm FINISHED WALL BASE MOUNT DETAIL FINISHED FLOOR FINISHED FLOOR FINISHED FLOOR 26 1 8 663mm 36 914mm 36 1 2 927mm 36 1 2 927mm 40 1 8 1020mm 2 3 4 ...

Страница 2: ...f mounting surface 2 Assemble C WASHER 4 STAR WASHER 5 and LOCKNUT 6 onto threads of SPOUT SHANK 3 from underside of mounting surface 3 Align FAUCET and tighten LOCKNUT 6 1 Apply plumber s putty to the underside of flange Install GRID DRAIN into drain outlet 2 From the underside of SINK install RUBBER GASKET flat side up and FRICTION GASKET onto GRID DRAIN threads Apply sealent to threads of GRID ...

Страница 3: ... BRACKET Replace NYLOCK NUT WASHER tighten both ends Do not over tighten chinaware could become damaged NYLOCK NUT AND WASHER HANGER STUD COLD WATER OR TEMPERED WATER 3 8 SUPPLY HOT MIXING VALVE MIXING VALVE SCREWS MOUNTING PLATE ELECTRONIC BOX ELECTRONIC BOX COLD 1 2 1 Connect SUPPLY NUT 1 from SPOUT assembly to nipple on top of ENCLOSURE 2 Tighten with adjustable wrench to make a water tight con...

Страница 4: ...e COVER from MIXING VALVE 2 Install FIBER SEAL WASHER 4 on MIXING VALVE NIPPLE 3 Hold MIXING VALVE 1 in place with one hand and with your other hand thread SWIVEL NUT 2 onto MIXING VALVE NIPPLE 3 Use an adjustable wrench to tighten SWIVEL NUT 2 3 Place MIXING VALVE BOX onto MOUNTING PLATE Align BOX with mounting holes Attach with SCREWS provided 4 Replace COVER and tighten securely NOTE For comple...

Страница 5: ...ea only 1 905 3061093 SELECTRONIC Proximity ICU Faucet Certified to comply with ASME A112 18 1M 2011 American Standard To learn more about American Standard Faucets visit our website at www us amstd com or U S customer s e mail us at faucetsupport amstd com For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 NOTE TO INSTALLER Please give this manual t...

Страница 6: ...TING SCREWS AND ANCHORS NOT SUPPLIED Use Brackets to mark pilot holes on wall Drill holes for ANCHORS Peel off the protective strip from the back of the APRON BRACKETS Apply the two APRON BRACKETS to the finished wall parallel to the pencil marks as shown and aligned with the mounting holes See illustration below Install SCREWS and tighten 4 Clean off the pencil marks from wall 6 152mm APRON SINK ...

Страница 7: ...E LIABLE FOR THE COST OF REPAIR OR REPLACEMENT OF ANY INSTALLATION MATERIALS INCLUDING BUT NOT LIMITED TO TILES MARBLE ETC American Standard will not be responsible for any other incidental or consequential damages attributable to a product defect or to the repair or exchange of a defective product all of which are expressly excluded from this limited warranty This limited warranty does not cover ...

Отзывы: