When installing whirlpool massage baths, air spa baths, combo baths, or Quick Drain™ 

equipped baths, the following precautions 

must 

be followed: 

 WARNING:  

Danger: Risk of electrical shock; connect components to separate circuits, EACH protected 

by a ground fault circuit interrupter (GFCI) 

 WARNING:  

Installation must provide access for servicing the pump and motor (all American 

Standard® walk-in baths come with access panels for the pump, motor and faucet). 

 
1.  Install tub waste/overflow according to instructions included with the provided kits.  The Gel Coat Series     
      requires the installation of a door drain with check valve.  

The check valve and tubing must be installed   

     horizontal to the floor.

  Some installations will require the purchase of additional fittings. 

 
2.  American Standard Faucet Installation #  9FHS-CH 

 

Review the installation instructions packed with the faucet set. 

 

Mask off the tub’s deck with a protective tape. 

 

Locate and mark the center line of the overflow fitting 

 

Locate and mark 1 ½” line either side of the tub’s center line to establish the overflow clearance.   

 

Follow the drill template and faucet installation instructions. 

 
3.  Other Faucet Model and / or Brand 

 

Review the installation instructions packed with the faucet set. 

 

Mask off the tub’s deck with a protective tape. 

 

Locate and mark the center line of the overflow fitting 

 

Locate and mark 1 ½” line either side of the tub’s center line to establish the overflow clearance. 

 

Verify the first two component mounting clearance on either side of the waste overflow as well as 
above and below the tub’s deck. 

 

Verify the remaining component mounting clearance on both sides of the overflow as well as above 
and below the tub’s deck. 

 

It is recommended the hand held shower be installed on the corner closest to the wall to prevent water 
from leaking off the deck and on to the floor. 

 
4.  Install the optional in-line water heater per manufacturer’s instructions. 
 
5.  Standard Walk-In Bath Installation

 - 

After framing is complete, set product in place to check fit and make 

certain that the tub can be properly leveled.  (Caution: If the bathtub is not resting on all leveling feet, water 
will not drain properly and this may cause the door to leak).  

Secure tub frame to the studs using metal 

straps.

 

(Not provided.) 

 
5a. Fire-Rated Drywall – If fire-rated drywall is specified, the finished fire-rated wall must be in place before  

the tub is installed.  The dimensions of the framing structure must be increased by the thickness of fire-
rated drywall. 

Содержание 2651.11X

Страница 1: ...WALK IN BATH INSTALLATION INSTRUCTIONS AND OWNER S MANUAL...

Страница 2: ...now the owner of a walk in bathtub from the most trusted name in plumbing We thank you for your purchase Your American Standard walk in bath is a true investment in your health and peace of mind Cust...

Страница 3: ...ALLER Page 4 TESTING YOUR TUB BEFORE INSTALLATION Page 5 INSTALLATION PREPARATION Page 6 ELECTRICAL INSTALLATION Page 7 INSTALLATION PROCEDURES Page 8 17 SAFETY INSTRUCTIONS Page 18 OPERATING INSTRUCT...

Страница 4: ...med to be installation related if not reported prior to installation Installers are also responsible for damage that occurs once the unit is placed in its niche NOTE Remove all packaging material exce...

Страница 5: ...staller assumes all liabilities for installation procedures Although American Standard has taken reasonable precautions to ensure that the Quick Drain TM is suitable for residential plumbing it is the...

Страница 6: ...r pump and heater if applicable for another 30 minutes and inspect for leaks again Inspect the unions around the pump and heater f If a leak persists at a union after tightening it may have been over...

Страница 7: ...et to perfectly level the tub Note It is important that all leveling feet are completely touching the floor and level for the door system to work properly 2 Check to ensure that the drain piping has b...

Страница 8: ...QUICK DRAIN LIGHTS WHIRLPOOL AIR SPA COMBO HEATER ELECTRIAL REQUIREMENTS This section lists the factory installed components of the Whirlpool and or Air Spa Systems Note the required number of circui...

Страница 9: ...instructions 3 Other Faucet Model and or Brand Review the installation instructions packed with the faucet set Mask off the tub s deck with a protective tape Locate and mark the center line of the ov...

Страница 10: ...fy the product is completely level by checking tub deck surface and ensure all leveling feet are touching the ground 7 Electrical connection is made by simply plugging each cord into the GFCI outlet 8...

Страница 11: ...ded The tile flange should be installed on the tub before it is placed in the alcove Install the tile flange along all sides of the tub where the wall will be Measure to fit and miter cut the flange c...

Страница 12: ...ord the distance from the tub and apron to the adjacent alcove wall Steps 2 3 4 Mask off and mark the trim lines for the top and front extension panels Using a high speed carbide tooth blade cut along...

Страница 13: ...ove and install the front and then top panel with the self tapping fasteners Steps 7 8 Apply the temporary clamps to help support the front and top panels while re locating the tub back into the alcov...

Страница 14: ...cove walls Level the tub along the deck and apron Measure the distance from the tub and apron to the alcove wall Verify the fit of both front and top extension panels Step 2 Mark a horizontal line tha...

Страница 15: ...the alcove Install the front and then the top panel with the tub brackets Step 4 Apply the temporary clamps to help support the panels while re locating the tub back into the alcove Remove temporary...

Страница 16: ...rflow Connection of the Quick Drain Quick Drain System requires the connection to a minimum 1 sanitary drain line Use UPC Approved PVC Glue Primer and Schedule 40 1 pipe Do not change or modify the lo...

Страница 17: ...rimer and Schedule 40 1 pipe The door drain check valve and 3 8 vinyl tubing are installed on the walk in bathtub The door drain coupling has an integral 3 8 barb for connection of the door drain line...

Страница 18: ...is equipped with adjustable jets or other flow control systems the pre set pressure switch may not activate the heater To assure proper heater operation all jets may need to fully open with the pump...

Страница 19: ...onsciousness or even drowning WARNING Pregnancy If you are or think you may be pregnant consult your doctor before using the bathtub WARNING Risk of personal injury Risk of electric shock do not permi...

Страница 20: ...sage valve located near the seat If equipped 4 The Legs Only Massage whirlpool combo systems only opens and closes the jets above the seat which allows you to fill the tub half way and operate only th...

Страница 21: ...nt purging and cleaning of the whirlpool and or air spa systems 12 Both whirlpool and air spa systems are designed so that water will drain from the plumbing after each use 13 There are no user servic...

Страница 22: ...ris from the cover and housing then remount the cover in place Suction covers with visible screws from inside the tub can be removed Some suctions are intended not to be removed and have no visible fa...

Страница 23: ...o liability shall exist for incidental or consequential damages caused in whole or part by any defect in this product No warranty expressed or implied including any warranty of merchantability or fitn...

Страница 24: ...ontrol Button should be illuminated If not verify the following a The pump is plugged into the control box b The control box is plugged into the outlet c The control button is plugged into the control...

Страница 25: ...or a leak in the suction line If the pump does not develop a vacuum and the pump has the correct water level check for proper voltage and or check the pump wet end for clogging or debris Air Massage M...

Страница 26: ...mum flow Heater Will Not Operate Check For Improper or loose connections open switches or relays blown circuit breakers Wiring loose connections etc Overload Amperage Reading O Zone Generators All O Z...

Отзывы: