Verify the electrical service to be in accordance with the manufacturer label located on the right side of
the unit.
Connect the unit to the mains.
Reach-In Models:
• Plug the unit into the wall receptacle
Condensate Drainage
Reach-In Models:
• Install drain pan or drain line. Install the drain pan by sliding the pan on the guides located on the
bottom of the unit.
• When installing the drain line the drainage connection must be carried out in conformity with the local
regulation. As a standard configuration, all reach-in Hurrichill units are provided with ¾” ID flexible
tubing drain line.
Install wire shelves (if so equipped).
Operate the unit in Hard Chill / Manual mode for approximately 20 minutes to verify temperature pull down,
see chapter Unit Operation – Manual Mode any Cycle.
Verify proper airflow direction.
• Evaporator – front to back
• Condenser – front to back
Installation Checklist (Cont’d)
3