Modular HURRiCHiLL Installation & Operations Manual

Automatic Mode Screen

1) Status Label – Displays the selected cycle and the status of the cycle. 

Status:
READY TO START – unit in standby mode waiting for the user to make a selection such as Start
CYCLE IN PROGRESS – the chilling cycle is in progress
COMPLETED – the chilling cycle has been completed and the unit is maintaining the product at safe holding 

temperatures 

2) Auto Mode Button – Press to select the automatic blast chilling mode.

3) Manual Mode Button – Press to switch to the manual blast chilling mode.

4) A la carte Mode Button – Press to switch to the A la carte blast chilling mode. 

5) ELAPSED TIME Label – Displays the elapsed time form the start of the cycle.

6) Food probe #... Label/Button – Press to assign to the current probe the food ID that it monitors. The assigned 

food ID will show on the HACCP reports. The label of Food probe #... will display the temperature of the probe. 

One food probe is the standard configuration for all American Panel Corporation blast chillers, the controller 

supports up to 4 food probes.

7) Air probe #... Label – Displays the air temperature inside the cabinet. Double and triple depth cabinet models will 

have two and three air probes respectively, one for each cabinet.

8) Time and Date Label – Displays the current date and time.

9) Home Button – Press to stop the current cycle and switch to the home screen.

10) Start/Stop Button – Press to start or stop the cycle. If the stop button will be pressed during the cycle a 

confirmation screen will prompt the user to confirm the choice. 

Содержание AP20BC Series

Страница 1: ...this equipment This manual is updated as new information and models are released Visit our website for the latest manual 990261_Modular_HC_OEM 07 22 5800 SE 78th St Ocala FL 34472 352 245 7055 service...

Страница 2: ...A La Carte Mode Screen 28 Start a Cycle in A La Carte Mode 29 Start a Cycle in Quick Start Mode 30 Customize the Quick Start Button 30 PC Connection Package 31 Connect to Controller Direct Connection...

Страница 3: ...warranty must be authorized by American Panel Corporation and performed by a factory authorized service agency This warranty does not apply to remote or pre assembled remote refrigeration systems req...

Страница 4: ...block the ventilation openings of the unit and of the structure in which it is positioned WARNING Please read the entire installation procedure before attempting to install the unit Failure to follow...

Страница 5: ...tallation The condensing unit must be installed and connected in accordance with the installation manual provided with the condensing unit The condensing unit and the cabinet must be connected to sepa...

Страница 6: ...4 000 AP26BCF 2T 208 60 1 15 5 A Medium Low Temp 68 000 AP26BCF 3T 208 60 1 22 7 A Medium Low Temp 102 000 AP36BCF 1T 208 60 1 8 2 A Medium Low Temp 44 000 AP36BCF 2T 208 60 1 15 5 A Medium Low Temp 8...

Страница 7: ...o familiarize oneself with potential problems such as building walls ceilings floors or concrete slabs These items need to be considered when preparing the site It is critical that the unit fits prope...

Страница 8: ...engaging the locking arm to the lock pin The cam action of the lock will pull the panels together compressing the factory applied gaskets and providing an air tight seal Finally rotate the panel lock...

Страница 9: ...a for units with model number ending with 1T 2 ea for units with model number ending with 2T 3 ea for units with model number ending with 3T 2 Electrical Panel 1 ea Blast Chiller 3 Center Air Deflecto...

Страница 10: ...Diagram Unit Assembly 1 Place and level the floor 2 Assemble the left right and rear wall panels Fasten panels to floor panel 3 Place the evaporator assembly inside the unit This is a temporary positi...

Страница 11: ...the wall where the evaporator assembly will be installed Align the top of the corner air deflectors to the ceiling panel Align the center air deflector at 9 below the ceiling panel Be sure the center...

Страница 12: ...r to the roof panel using the 3 8 screws washers and nuts provided Take your time and tighten each screw one turn at a time in a diagonal pattern to avoid damaging the screws 10 Remove and discard the...

Страница 13: ...e drain pan and after that tighten the wing nuts Make sure the diverter does not touch the bottom of the drain pan Route the drain line and connect the drain pan to it When drilling the opening for th...

Страница 14: ...te the cables and connectors through the line set opening 17 Make the electrical connections inside the evaporator assembly If the blast chiller is equipped with pass thru door install the provided J...

Страница 15: ...on Operations Manual P 800 327 3015 E Service americanpanel com Step Description Diagram 19 Install and secure the provided stainless steel cowlings atop the unit 20 Make the main electrical connectio...

Страница 16: ...tors Installation When installing a unit with multiple evaporators refer to the provided floor plans to assemble the cabinet and refer to Unit Assembly section of this manual to install the air deflec...

Страница 17: ...Blast Chiller 3 31 x 38 x 73 5 1 080 N A AP46BC 1T Blast Chiller 1 35 x 39 x 73 5 460 N A AP46BC 2T Blast Chiller 2 35 x 39 x 73 5 920 N A AP46BC 3T Blast Chiller 3 35 x 39 x 73 5 1 380 N A AP20BCF 1T...

Страница 18: ...els AP46 15 clearance above the unit for service Provide enough space in front to allow door opening Check for unobstructed air at the condensing unit 4 Check to ensure the unit is level 5 Confirm the...

Страница 19: ...net and or cycle is stopped by the operator A La Carte The air temperature will cycle between 28 F and 35 F until all the timers expire after that the unit will switch into holding mode where the air...

Страница 20: ...d by the operator Manual Mode The air temperature will cycle between 25 F and 15 F for 4 hours After 4 hours the unit will switch into holding mode where the air temperature will cycle between 4 F and...

Страница 21: ...haw probe will reach 32 F at this point the blast chiller will switch into holding mode where the air temperature will cycle between 35 F and 42 F until the food is removed from the cabinet and or cyc...

Страница 22: ...35 F 42 F Hard Chillers Freezers 0 F 10 F 60 F 28 F 35 F 40 F 35 F 42 F Shock Freeze 25 F 15 F NA NA NA 0 F 4 F 3 F Thaw 42 F 50 F NA NA NA 32 F 35 F 42 F Factory Presets Manual Mode Quick Reference...

Страница 23: ...the desired cycle see Settings Quick Start 5 Food Thaw Button Press to access Food Thaw Cycle Menu Food Thaw Cycle is an optional cycle and is available on selected models only 6 Sanitize Button Press...

Страница 24: ...e 5 ELAPSED TIME Label Displays the elapsed time form the start of the cycle 6 Food probe Label Button Press to assign to the current probe the food ID that it monitors The assigned food ID will show...

Страница 25: ...Step Description Action 1 Choose Soft Chill Hard Chill or Shock Freeze from the Home screen 2 Make sure Auto tab is selected For the Auto mode to work as intended the food probe must be inserted into...

Страница 26: ...tes the remaining time to the end of the cycle 6 UP DOWN BUTTONS Press to adjust the cycle time as needed 7 Food probe Label Button Press to assign to the current probe the food ID that it monitors Th...

Страница 27: ...Mode Step Description Action 1 Choose Soft Chill Hard Chill or Shock Freeze from the Home screen 2 Make sure Manual tab is selected 3 Optional Press up or down on the time arrows to adjust the cycle...

Страница 28: ...s Press to access the timer setting screen The timer label will indicate the remaining time and the product name of the food it monitors 6 Food probe Label The label of Food probe will display the tem...

Страница 29: ...k Freeze from the Home screen 2 Make sure A la carte tab is selected 3 Select any available timer Available timers are the ones set at 00 00 and have not yet been activated 4 Optional Press Food ID to...

Страница 30: ...but can be customized in the settings for any cycle operation Press the Quick Start button to engage the preset cycle To customize the Quick Start button follow the steps below Step Description Actio...

Страница 31: ...r is set from the factory as a Wi Fi access point In this configuration the controller broadcasts an SSID such as blast chiller xxxxxxxxxxx wha Step Description Action 1 Open the Wi Fi connections on...

Страница 32: ...ough the Direct Connection steps outlined on pg 28 Once connected on a browser complete the steps below 2 Press the Go to config button at the bottom of the screen 3 Make sure the Device config tab is...

Страница 33: ...e wi fi settings by selecting the Settings button on the home screen of the unit 8 Enter the controller password and hit done 9 Press the PC button to access the wi fi settings 10 Press the Wi Fi Conf...

Страница 34: ...m of the screen 3 Make sure the Email Notifications tab is selected 4 Enter the info for the fields below STP server name Port type Email address notifications will come FROM Email account password Em...

Страница 35: ...home screen in your browser 3 Click Refresh to load the most current data Wait until the refresh is complete the bar will hit 100 and you will see the updated data on screen 4 Click the Download butto...

Страница 36: ...in the Quick Start button Defrost Settings for Length of Defrost Auto Defrost Auto Defrost Time Cabinet Max Temp Length of Auto Defrost Date Time Language Sets the time date and language English Frenc...

Страница 37: ...es Probe Settings Adjust probe temperatures and offsets Contacts Settings Settings for contact sensors in the unit Features Technical features to be used by technician Alarm Settings Settings for all...

Страница 38: ...obing of the product Insert the food probe into the thickest part of the product The tip of the food probe will have to be located at the core of the food Always place the available food probe in the...

Страница 39: ...20 ice water bath to check the accuracy of the probe To do so close the door of the unit with the probe hanging on the outside of the cabinet and start a manual hard cycle Use the probe to continually...

Страница 40: ...s functional Turn unit off wipe down exterior On the remote condensing unit perform the maintenance procedure recommended by its manufacturer Inform the customer and the factory if any functional and...

Страница 41: ...ristle to remove the surface loaded fibers and dirt Apply the tool in the direction of the fins Rinse the coil finned area and the return bends with plenty of clean warm water To avoid damaging the fi...

Страница 42: ...The evaporator door is the sheet metal that houses the evaporator fans To open it remove the screws located on the right hand side of the evaporator door opposite to the hinges The ozone generator is...

Страница 43: ...43 5800 SE 78th St Ocala FL 34472 Modular HURRiCHiLL Installation Operations Manual P 800 327 3015 E Service americanpanel com Notes...

Страница 44: ...ear family owned and operated heritage American panel provides versatile dependable custom crafted walk in coolers freezers combination cold rooms and blast chillers American Panel is proud to offer t...