American National Manufacturing Static LAL 8100 Скачать руководство пользователя страница 4

 

4 of 16 

 

8100 LAL 

General Warnings and Precautions

 

 
 
WARNINGS 

 

 

WARNING: 

DO NOT use this device if the power cord is cut, frayed or loosely 

connected to the device. 

 

WARNING: 

Electrically Powered Mechanism.  Electrical Hazard may occur if 

device is plugged into inadequate electrical outlet.  To avoid electrical shock 
hazard, make sure unit is plugged into a grounded A/C 110 Volt outlet.  

 

 
WARNING: 

DO NOT remove cover.  Refer servicing to qualified service 

personnel.  Disconnect power supply before servicing or cleaning. 
 

WARNING:

 Be sure to secure mattress to the bed frame with the straps 

provided.  Failure to do so could result in personal injury or equipment damage. 

 

CAUTIONS

 

 

CAUTION:

 Overheating may cause equipment damage or failure.  Monitor the 

unit to ensure that it functions in the proper operating temperature. 
 

CAUTION:

 Keep out of direct sunlight.  

  

CAUTION

: DO NOT store in temperatures below 40° or greater than 95° 

Fahrenheit (5° – 35° Celsius). 
  

CAUTION:

 DO NOT expose to moisture or areas of extreme humidity. 

 

CAUTION:

 Ensure that strap placement does not interfere with the operation of 

the bed functions. 
 

CAUTION: 

Medical Electrical Equipment needs special precautions regarding 

EMC and needs to be installed and put into service according to the EMC 
information provided in this manual. Portable and mobile RF communications 
equipment can affect Medical Electrical Equipment. The use of Accessories, 
transducers, and cables other than those specified by the manufacturer, may 
result in increased emissions or decreased immunity of the equipment or system. 
The equipment or system should not be used adjacent to or stacked with other 
equipment and that if adjacent or stacked use is necessary, the equipment or 
system should be observed to verify normal operation in the configuration in 
which it will be used. 

 
 

CAUTION: 

DO NOT use around an open flame.

 

Содержание Static LAL 8100

Страница 1: ...Static Low Air Loss Mattress Replacement System Read Entire Manual before Operating Device ANSLAL Uncontrolled Document Rev 1 0 08 26 2008 User Instruction Manual...

Страница 2: ...arnings and Precautions 4 Seven Zones of Bed Rail Entrapment 5 Device Information 6 Unpacking and Set up 7 Operating Instructions 8 Keypad Quick Reference 9 Mattress Cleaning Instructions 10 Blower Un...

Страница 3: ...ient or user injury A CAUTION points out special procedures or precautions that personnel must follow to avoid equipment damage This symbol highlights an ELECTRICAL SHOCK HAZARD WARNING Symbols Found...

Страница 4: ...out of direct sunlight CAUTION DO NOT store in temperatures below 40 or greater than 95 Fahrenheit 5 35 Celsius CAUTION DO NOT expose to moisture or areas of extreme humidity CAUTION Ensure that stra...

Страница 5: ...em the caregiver is responsible for seeing that the mattress properly fits the bed frame It is also the caregiver s ultimate decision whether or not to use bed rails with the patient Zone One Zone Two...

Страница 6: ...l panel that has a turn dial for pressure adjustment Inside the Control Unit is a variable output blower that allows the air mattress to operate in static mode There is also a printed circuit board wh...

Страница 7: ...s Fahrenheit DO NOT expose to moisture or areas of extreme humidity Portable and mobile RF communications equipment can affect Medical Electrical Equipment The use of Accessories transducers and cable...

Страница 8: ...7 Turn master power switch located on the side of the unit on 8 Press the Autofirm button for quick inflation 9 Press the Firm or Soft button on the control panel to select the desired level of firmn...

Страница 9: ...n Lockout Locks all functions auto matically after 3 mins To disable press and hold lockout button for 3 sec Firm Increases airflow for a firmer setting Alarm Silence Mutes the audible alarm Visual li...

Страница 10: ...interior sacs must be hand cleaned only DO NOT place in sterilization room or chamber Use a spray disinfectant to wipe down interior sacs Air dry sacs DO NOT expose to heat 4 Spray disinfectants and w...

Страница 11: ...our representative for servicing NOTE To keep your equipment working efficiently and effectively for an extended time period it is essential to make sure the equipment is cleaned regularly and well ma...

Страница 12: ...of the hoses are punctured kinked or disconnected Check for proper connections from the hoses to the pump Make sure they are secure Check or clean intake filters Be sure CPR valve on the mattress is c...

Страница 13: ...unit to be hung on bed frame Female CPC Connects from mattress to Male CPC on blower unit Removes exhaust air from unit to mattress Male CPC Chrome Attached to blower unit side panel Connects to Femal...

Страница 14: ...ons Warranty American National Manufacturing Inc Warrants that all products provided under this agreement are free from defects in material and workmanship for the following stated warranty period fro...

Страница 15: ...15 of 16 8100 LAL Notes...

Страница 16: ...m All specifications equipment and prices are subject to change without notice Photos and drawings are representative of the products and may vary slightly from actual production models Contact or con...

Отзывы: