NOTE
The current must be less than 0.1% of I
max
in order to change the
Select Supply picklist value. If a change is attempted with current
above this value, the Model 430 Programmer will beep and ignore
the keypress. Power supply selection should also preferably be
performed with the power supply off for maximum safety.
Select Supply picklist values and associated parameters.
Power Supply
Min Output
Voltage (V)
Max Output
Voltage (V)
Min Output
Current (A)
Max Output
Current (A)
V-V Mode Input
Range (V)
AMI 08150PS
0
+8.000
0
+150.000
0 to +10.000
AMI 12100PS
0
+12.000
0
+100.000
0 to +10.000
AMI 12200PS
+200.000
AMI 4Q05100PS
−
5.000
+5.000
−
100.000
+100.000
−
10.000 to +10.000
AMI 4Q06125PS
-6.000
+6.000
-125.000
+125.000
AMI 4Q06250PS
-250.000
+250.000
AMI 4Q12125PS
-12.000
+12.000
-125.000
+125.000
AMI 10100PS
0
+10.000
0
+100.000
0 to +5.000
AMI 10200PS
+200.000
AMI 05120PS
+10.000
a
+100.000
0 to +10.000
AMI 05240PS
+200.000
AMI 05360PS
+300.000
AMI 05600PS
+500.000
AMI 03300PS
+8.000
+300.000
HP 6260B
−
10.000
+10.000
0.000
+100.000
Kepco BOP 20-5M
b
−
5.000
+5.000
−
10.000 to +10.000
Kepco BOP 20-10M
−
10.000
+10.000
Xantrex XFR 7.5-140
0
+7.500
0
+140.000
0 to +10.000
Custom...
c
−
20.000
+20.000
−
200.000
+200.000
−
10.000 to +10.000
a. The individual 05100PS power supply unit will 10.000 VDC at up to 120 A. However, the standard configuration of
this series of power supplies includes the Model 601 Energy Absorber to provide bipolar operation. The 05xx0-430-601
series of power supply systems provides a maximum available voltage to the load of
±
5.000 VDC at multiples of 120 or 150
A, up to 600 A depending on the system selected.
b. The Kepco BOP power supplies are used in the 4Q1005PS-430 and 4Q1010PS-430 systems are limited to only one-half the
output voltage range since the supplies are designed to safely
dissipate
only one-half the rated power output.
c. The values shown for the Custom... option are defaults. The user should enter the appropriate values within the respective
submenus. Custom values, once entered, are saved in nonvolatile memory.
Содержание 430
Страница 2: ......
Страница 16: ...XVI REV 9 AMERICAN MAGNETICS INC FOREWORD SAFETY SUMMARY ...
Страница 28: ...12 REV 9 AMERICAN MAGNETICS INC INTRODUCTION OPERATING CHARACTERISTICS ...
Страница 64: ...48 REV 9 AMERICAN MAGNETICS INC INSTALLATION POWER UP AND TEST PROCEDURE ...
Страница 208: ...192 REV 9 AMERICAN MAGNETICS INC SERVICE RETURN AUTHORIZATION ...
Страница 248: ...232 REV 9 AMERICAN MAGNETICS INC APPENDIX SHORT SAMPLE MODE ...