©2017 American Lighting, Inc.   REV1743   www.AmericanLighting.com

SELECTING POWER SUPPL

LED-DR DRIVERS FOR TRULUX® CONTROLLERS

Calculate the load and make sure to select a driver that can handle the total load. Use the chart below to select the driver.

HTMR Series tape light is not compatible with LP-DR series drivers. Recommended operation is with LED-DR series drivers only.

       * For run lengths that exceed the reel length (65.6 feet), use up to 26.8 feet from a second HTMR reel, locate the 150W driver in a central location and do not 
          exceed 65.6 feet in any single run.

 

CONNECTING AND MOUNTING TRULUX SECTIONS:

This product is designed to be mounted to a smooth, clean, non-moving surface.

1.  Review any marks made indicating placement of connectors prior to continuing. For best adhesion to surface, once Trulux 

backing is removed, it should be placed on mounting surface and not be repositioned or removed and re-used.

2.  Peel the protective backing from the tape light and press the first piece of Trulux into place, working from the “L”,  “T”, or “X” 

connection,where applicable.

3.  For extending any piece, connect a clip connector or jumper wire to the preceding piece by sliding the tape light end completely 

into the connector, ensuring the tape light is underneath the metal conductors, and closing the clip securely over the tape light 

until the connector halves ‘snap’  together. (See Figure 2). Compatible clip connectors  include TL-2SPL, TL-2L, TL-2T, and TL-2X. 

Jumpers (TL-2JUMP-.5, TL-2JUMP-1, and TL-2JUMP-2) are also available, sold separately. The clip and jumper connectors are 

shipped open, ready to use.

4.  Attach the next Trulux section to the clip connector/jumper in a similar manner.

5.  For best results, allow 24 hours for the adhesive to “cure” to the mounting surface before using lights.

6.  Mounting clips with screws are also available (TL-CLIPS-15, sold separately) to secure tape light in place.

7.  See page 3 for power supply and receiver connection.

Distances for LED-DR power supplies in Trulux Control System Applications - 5% MINIMUM load and 90% MAXIMUM load

Trulux Series

Watts

Per Foot

Max 

Run

LED-DR30-24

LED-DR60-24

LED-DR100-24

LED-DR150-24

HTMR Series

(1.97” cut marks)

1.46W/ft

65.6’

1.1ft - 18.6ft

(1.7 - 27.1 watts)

18.7ft - 36.9ft

(27.3 - 53.9 watts)

37.1ft - 61.6ft

(54.2 - 89.9watts)

61.7ft - 92.4ft*

(90.1 - 134.9 watts)

FIGURE 3

FIGURE 4

Cut marks are clearly marked and can be 

cut down the center.

To power supply

TRULUX

®

 HIGH OUTPUT MAX

24V

INSTALLATION INSTRUCTIONS

HTMR Series

Содержание TRULUX HIGH OUTPUT MAX Series

Страница 1: ...onal Electric Code NEC Use only with 24V DC drivers with a wattage capacity that can handle the total load see page 2 for more details Factory warranty will be void if used with a non recommended power supply transformer or driver To reduce the risk of fire electric shock or injury to persons make sure that the electrical power to the system is disconnected at the source prior to installation or a...

Страница 2: ...ece connect a clip connector or jumper wire to the preceding piece by sliding the tape light end completely into the connector ensuring the tape light is underneath the metal conductors and closing the clip securely over the tape light until the connector halves snap together See Figure 2 Compatible clip connectors include TL 2SPL TL 2L TL 2T and TL 2X Jumpers TL 2JUMP 5 TL 2JUMP 1 and TL 2JUMP 2 ...

Страница 3: ...EM CAPACITY POWER TO RECEIVER SRF BATT White dial 3V Battery CR203 included REC 5A 4Z 1 zones 5A max 24V DC input SRF 4Z 3P White touch 24V DC input not 120V REC 5A 4Z 4 zones 5A max 24V DC input See Figure 3 for an example of a multiple zone system However note that you can have receivers learn which zone they control so if you teach them all to respond to one zone then Figure 3 represents a sing...

Страница 4: ...USING PLUG IN POWER SUPPLY FOR TRULUX NON DIMMING 1 See plug in driver selection chart below 2 Attach the DC power lead adapter not included with 100ft reels to the existing lead matching polarity Attach DC jack from this power cord to DC jack of plug in power supply sold separately Plug power supply into 120V AC power source ADDITIONAL SAFETY MEASURES 1 Route and secure cords so that they will no...