![American Lighting NEOFLUX PRO V-Series Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/american-lighting/neoflux-pro-v-series/neoflux-pro-v-series_installation-instructions_2924675002.webp)
INSTALLATION INSTRUCTIONS
NFPROV
NEOFLUX PRO
V-SERIES
24V
Page 2 of 4
©2021 American Lighting, Inc. REV2147 www.AmericanLighting.com
11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
INSTALLING NEOFLUX PRO:
1. It is recommended that installation be performed by at least 2
persons to ensure proper handling of linear product and prevent
damage to the internal and external construction. See Figure 8.
2. Determine the desired locations and lengths of NeoFlux Pro to be
installed. Use this information to determine locations and sizes of
24V DC power supplies.
3. Install aluminum channel (PZM-NFPROV-CHAN-4) by screwing the
channel into a solid, sturdy surface. See Figure 89. The distance
between two parallel lines of NeoFlux Pro must be at least 1/2”.
4. Gently push the NeoFlux Pro into the channel starting at the begin-
ning of the run and moving down the line towards the end. Leave
enough room for the power cable to reach the power supply and
for connections to reach the next piece of NeoFlux Pro. End caps
cannot be installed within the aluminum channel. See Figure 10.
5. Ensure the NeoFlux Pro does not sag and does not bend more than
the maximum bend radius of 24cm at any point.
CARE AND MAINTENANCE:
1. For cleaning, use a soft, dry or damp cloth. Do not use harsh chemicals or abrasives.
FIGURE 9
FIGURE 4
FIGURE 3
FIGURE 5
FIGURE 10
Mounting Surface
Aluminum Extrusion
The end cap cannot be installed
into the aluminum extrusion
ATTACHING CONKITS, JUMPERS, & END CAPS (Figures 3-5):
Disconnect power at the source prior to attempting installation or
service of product. Neoflux Pro conkits and end caps are IP65 rated
when installed correctly.
1. Check the polarity of the cut-end on the Neoflux Pro to determine
which connector type is needed. See Figure 3.
2. To connect a DIY conkit or jumper, See Figure 4.
A.
First insert the "U" button into the neon.
B.
Insert the shell over the neon and push until seated.
C.
Lock the catch into the shell tightly.
D.
Put the waterproof slice piece onto the toothed end of the
conkit/jumper cable.
E.
Insert the cable with the waterproof slice into the shell on
the neon, ensuring the teeth are placed in between the PCB
board and the transparent board of the neon (the teeth must
not be on top of the PCB, otherwise it may damage the LEDs).
Note:
Prior to closing the connector, perform a quick light-up
test to ensure polarity and connection are correct.
F.
Close the neon with pressure cover and screws.
3. To connect a closed-end cap, See Figure 5.
A.
Insert the shell over the neon and push until seated, then
lock the catch into the shell tightly.
B.
Put the waterproof slice piece onto the end of the neon.
C.
Close the neon with pressure cover and screws.
CONNECTING POWER (Figures 6-7):
Disconnect power at the source prior to attempting installation or
service of product. Use this fixture with appropriate 24V DC power
supply only. Any other power supply may damage the fixture.
1. Connect a 24V DC power supply to the beginning of the
NeoFlux Pro run using the conkit attached in the previous section.
See Figure 6 for single color (2pin) wiring diagram. See Figure 7 for
RGBW (5pin) wiring diagram.
2. Connect the 24V DC power supply to line voltage. Single color
NeoFlux Pro does not require a controller, however, RGBW NeoFlux
Pro will require a form of RGBW control for color changing
capability. NeoFlux Pro is compatible with Trulux control systems
and other DMX control options.
FIGURE 6
Black
NeoFlux Power
Cable
Red
Positive (+)
Negative (-)
FIGURE 7
NeoFlux Power
Cable
Red
Yellow
Green
Blue
Black
Green
Black (Positive
+
)
Red
White
Blue
A
A
B
B
C
C
D
E
F
FIGURE 8
2 PERSON INSTALLATION RECOMMENDED
MINIMUM BEND RADIUS ≥24CM
≥24CM