NFPROV
NEOFLUX PRO
V-SERIES
24V
Page 1 of 4
©2021 American Lighting, Inc. REV2147 www.AmericanLighting.com
11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
FIGURE 1
SAFETY INFORMATION
• Read all installation instructions before beginning; if not qualified, do not attempt installation. Contact a qualified electrician.
• To reduce the risk of fire, electric shock, or injury to persons, pay close attention to this manual and stay within its guidelines when using this
product. Save these instructions for future use.
• Do not cover this product as the covering may cause product to overheat, melt, or ignite.
• Risk of fire or electric shock. Uncoil flexible light prior to plugging in. Do not operate NeoFlux Pro while it is tightly coiled.
• Do not route the cord or NeoFlux Pro through walls, ceilings, doors, windows, or any similar part of the building structure.
• Secure this flexible light using only factory recommended mounting channel (NFPROV-CHAN-1M), sold separately.
• Do not secure this product or its cord with staples, nails, or like means that may damage the outer jacket or cord insulation.
• Do not use if there is any damage to the PU housing or power cord insulation. Inspect periodically.
• Do not install on gates or doors, where subject to continuous flexing.
• Do not install near flammable liquids or other flammable materials.
• Follow instructions carefully when cutting NeoFlux Pro. Ensure all end caps are properly sealed.
• 24V NeoFlux Pro can only be cut at specific intervals as indicated by the cutting marks printed on the side of the PU housing (50mm or 1.96”
for single color 2pin type and 62.5mm or 2.46” for RGBW 5pin type). Failure to cut at a cut mark will result in a loss of light. Before making any
cuts or attaching any power cords or jumpers, be sure power source is disconnected at the source!
• This product is designed for use by a qualified installer.
• This product is for decorative use only. Not to be used by children as a toy. Keep out of reach of small children.
• Do not exceed maximum run distance in any single inter-connected run: 17m (55.7ft) for single color and 5m (16.4ft) for RGBW.
• Size your 24V DC driver appropriately for your run distance of NeoFlux Pro using 10W per meter or 3.05W per foot as a guide. Be sure not to
load any driver to 100% as this will reduce its efficiency. A 90% maximum load is recommended for driver longevity.
• The rated ambient temperature range for NeoFlux Pro is -25°C (-13°F) to 45°C (113°F).
• The maximum bend radius of PZM-NFPROV series product is 24cm or 9.4”. Do not twist, drop, hang, sag, or bend product in any way other
than intended. This product can only bend vertically in relation to its light output. See Figure 1 below for reference.
These products may represent a possible shock or fire hazard if
improperly installed or attached in any way. Products should be
installed in accordance with these instructions, current electrical
codes, and/or the current National Electric Code (NEC).
To reduce the risk of fire, electric shock or injury to persons, use
this flexible light only with American Lighting/Prizm recommended
drivers, controllers, power connectors, splices and extensions.
Use this fixture with a 24V DC power supply only (sold
separately). Any other power supply may damage the fixture.
To reduce the risk of fire, electric shock or injury to persons,
make sure that the electrical power to the fixture is
disconnected at the source prior to installation or any servicing.
When using outdoor portable lighting products, basic safety precautions should always be followed to reduce the risk of
fire, electric shock, and personal injury, including the following:
• Use only factory recommended power and linking connections. Use silicone or PU glue in end caps when using outdoors.
• Use ground fault circuit interrupter (GFCI) protection on the circuit(s) or outlet(s) when using outdoors.
• Use only UL approved outdoor extension cords, such as type SW, SOW, STW, STOW, SJW, SJOW, SJTW, or SJTOW. This designation is
marked on the jacket of the extension cord.
WARNING
WARNING
WARNING
WARNING
WARNING
Do not operate
NeoFlux Pro while it is
coiled or on the reel.
Do not hang
Do not
droop or sag
Lighted
Surface
>24cm
CUTTING NEOFLUX PRO:
Disconnect power at the source prior to
attempting installation or service of product.
1. Determine the desired location of the cut based on the cutting
increments marked on the bottom of the NeoFlux Pro (50mm or 1.96”
for single color 2pin type and 62.5mm or 2.46” for RGBW 5pin type).
2. Using an appropriate utility blade, gently cut straight down through
the body of the NeoFlux Pro, directly on the cutting increment mark
on the bottom of the NeoFlux Pro. Do not use scissors or bolt cutters
to cut NeoFlux Pro. Do not cut NeoFlux Pro diagonally or horizontally
as this may damage the product. See Figure 2.
3. All cut ends should be sealed using a conkit, jumper, or end cap.
FIGURE 2
Cut along the
cut-mark on the
backside of the
NeoFlux