3
Interrupters User Guide
14
Chapter 3:
GPS350 Installation
The GPS350 interrupter consumes approximately 120 mA. The built-in solid state relay current
consumption is additional 100 V / 80 A max with > 4 s cycle or 100 V / 60 A max with 1 s-4 s cycle.
The relay is
normally closed
.
The interrupters are set to use Normally Closed relays by default. If you plan to use a Normally Open
relay, configure the interrupter prior to installing it.
The GPS350 installation process includes the following steps:
l
Installing the GPS350 Interrupter on page 14
l
Setting Display Contrast on page 18
l
l
Running a Test Program on page 19
Installing the GPS350 Interrupter
When completing the following procedure, refer to
Technical Specifications on page 57
output voltage specifications.
WARNING:
Make sure to follow all precautions when working with the interrupter and high
voltage circuits.
WARNING:
Do not connect the MicroMax GPS350 to primary mains power.
Metal relay casing on the GPS350 will get hot. Allow 5 - 10 minutes after interruption stops before
handling the unit.
The installation process includes the following steps. Refer to the individual sections for each step
for the complete instructions.
l
Determining a Power Source on page 15
l
Connecting the Built-in Relay to a Rectifier on page 15
— or connect an external relay