American Hearth ALX-24VR-1 Скачать руководство пользователя страница 4

R10580-2-0311

Page 4

REQUIREMENTS FOR CANADA

This unit 

cannot

 be installed in an UNVENTED application, this 

unit

 can only 

be  installed  as  a  VENTED  application  with  these 

requirements.

IMPOrTANT SAfeTY INfOrMATION

This  unit  complies  with  ANSI  Z21.60and  CGA  2.26  Decorative 

Gas Appliances For Installation In Solid Fuel Burning Fireplaces. 

Do not burn wood or solid fuels in a fireplace where a decorative 

gas  log  set  is  installed. This  appliance  is  for  installation  only  in 

a solid fuel burning fireplace, masonry fireplace or manufactured 

fireplace.

warning: 

Any modification to this gas log set or to controls can 

be dangerous. Improper installation or use of the gas log set can 

cause serious injury or death from fire, burns, explosion or carbon 

monoxide poisoning.
1.  Please follow all local codes regarding installation, combus-

tion and ventilation air or in the absence of local codes follow 

the National Fuel Gas Code ANSI Z223.1(U.S. installation), or 

CAN/CGA-B149, Installation Code (Canada installation).

2.  Proper installation, burner pan location and log placement is 

important to achieve optimum look and performance of your 

gas log set. The logs have been designed for easy location 

and placement on the grate and the log placement instruc-

tions must be followed for proper operation.

3.  Do not operate this log set with glass doors in the closed posi-

tion. A fireplace screen must be in place when the log set is 

burning. Adequate combustion air must be provided for proper 

venting. All flames should go up and out the top of the firebox 

into the flue vent. If any flames float or curl forward into the 

room do not operate appliance. Check for an open flue and 

adequate combustion air into the room. A damper clamp must 

be installed on the firebox damper to maintain an open flue 

vent condition.  Refer to fireplace owners manual INSTALL

-

ING DAMPER CLAMP section.

4.  Young children must be carefully supervised when they are in 

the same room as the gas log while in operation. Do not place 

stockings, clothing or any flammable material above or near 

the fireplace.

5.  Do not substitute or use materials other than those supplied 

for use with the log set.

6.  Also  refer  to  IMPORTANT  SAFETY  INFORMATION  in  the 

fireplace Owner's Manual.

WARNING;  DO  NOT  OPERATE  THIS  GAS  LOG  SET  WITH 

gLASS DOOrS cLOSeD

• 

Clothing or other flammable material should not be placed on 

or near the appliance.

• 

Do not place trash or other articles on the log set during op

-

eration.

• 

During manufacturing, fabricating and shipping, various com

-

ponents of this appliance are treated with certain oils, films or 

bonding agents. These bonding agents are not harmful but 

may produce annoying smoke and smells as they are burned 

off during initial operation of the appliance. This is a normal 

temporary occurrence. A window should be opened during the 

initial bake out period. 

• 

Keep burner and control compartment clean. 

• 

wArNINg: 

Before installing in a solid fuel burning fireplace, 

the chimney flue and firebox must be cleaned of soot, creo

-

sote, ashes and loose paint by a qualified chimney cleaner.

• 

Installation and repair should be done by a qualified service 

person. The appliance should be inspected before use and 

at least annually by a qualified service person. More frequent 

cleaning may be required due to excessive lint from carpet-

ing, bedding materials, hair from pets, etc. It is imperative that 

control  compartments,  burners  and  circulating  air  passage-

ways of the appliance be kept clean.

• 

Do not

 put anything around the fireplace that will obstruct the 

flow of ventilation air.

• 

Do

 keep the appliance area clear and free from combustible 

material, gasoline and other flammable vapors and liquids.

• 

A yearly examination and cleaning of the venting system of 

the solid-fuel burning fireplace must be performed by a quali

-

fied agency.

• 

Do

 make a periodic visual check of pilot and burners. Clean 

and replace damaged parts.

• 

Do not

 use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and 

any gas control which has been under water. 

• 

Never burn solid fuels in fireplace where a gas log set is in

-

stalled.

• 

This unit complies with ANSI Z21.60 Decorative Vented Appli

-

ances for Solid Fuel Burning Fireplaces. State or local codes 

may only allow operation of this appliance in a vented configu

-

ration. Check your regional or local codes.

Содержание ALX-24VR-1

Страница 1: ...installer service agency or the gas supplier WARNING If the information in these in structions are not followed exactly a fire or explosion may result causing property damage personal injury or loss...

Страница 2: ...on Guidelines 3 General Information 3 Requirements for Canada 4 Parts List Parts View 5 Log Placement 6 12 Placement of Glowing Embers 13 15 Master Parets Distributor List 16 How To Order Repair Parts...

Страница 3: ...up around or inside the venturi Any obstruction in the venturi tube area must be removed The flow of air into the venturi is also reduced if the gas orifice isn t centered in the venturi inlet and or...

Страница 4: ...ther than those supplied for use with the log set 6 Also refer to IMPORTANT SAFETY INFORMATION in the fireplace Owner s Manual WARNING DO NOT OPERATE THIS GAS LOG SET WITH GLASS DOORS CLOSED Clothing...

Страница 5: ...Use of Any Other Parts Could Cause Injury Or Death PARTS LIST PARTS VIEW Index No Part No Description ALX 24VR 1 ALX 30VR 1 A R10547 R10547 LEFT LOG B R10549 R10555 CENTER LOG C R10550 R10556 REAR LO...

Страница 6: ...ays wear gloves to prevent skin irritation After handling logs wash your hands gently with soap and water All Logs The positioning of the logs is critical to the safe and clean operation of this heate...

Страница 7: ...R10580 2 0311 Page 7 FRONT VIEW TOP VIEW 1 Place Left Log A onto pins 4 and 8 LOG PLACEMENT...

Страница 8: ...R10580 2 0311 Page 8 LOG PLACEMENT 2 Place Center Log B horizontally onto pin 1 Log fits over the gap and rests against the Rear Log Shelf FRONT VIEW TOP VIEW...

Страница 9: ...R10580 2 0311 Page 9 LOG PLACEMENT 3 Place Rear Log C onto pin 3 and rest against Rear Log shelf next to B Log FRONT VIEW TOP VIEW...

Страница 10: ...R10580 2 0311 Page 10 LOG PLACEMENT 4 Place Front Log E onto pins 5 6 and 7 FRONT VIEW TOP VIEW...

Страница 11: ...R10580 2 0311 Page 11 LOG PLACEMENT 5 Place Top Left Log F onto boss on A Log and resting on B Log FRONT VIEW TOP VIEW...

Страница 12: ...R10580 2 0311 Page 12 LOG PLACEMENT 6 Place Right Top Log F onto C Log and rectangle boss on E Log FRONT VIEW TOP VIEW...

Страница 13: ...R10580 2 0311 Page 13 PLACEMENT OF GLOWING EMBERS...

Страница 14: ...R10580 2 0311 Page 14 PLACEMENT OF GLOWING EMBERS...

Страница 15: ...duction embers to the burner Placement of the glowing embers is very individual and light coverage will provide your best effects We recommend separation of the glowing embers by hand and make your co...

Страница 16: ...treet Hartford CT 06114 Phone 860 722 2433 Toll Free 800 243 9360 Fax 860 293 0479 Toll Free Fax 800 274 2004 Websites www fwwebb com www victormfg com Parts Heater Hearth and Grills MASTER PARTS DIST...

Страница 17: ...R10580 2 0311 Page 17 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 18: ...R10580 2 0311 Page 18 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 19: ...R10580 2 0311 Page 19 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed Notes...

Страница 20: ...Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question pl...

Отзывы: