american flame AFVK-SP-H/L-SPLIT Скачать руководство пользователя страница 8

OPERATING PROCEDURE

After installation is completed follow these steps to operate the

 

AFVK-SP-SPLIT

.

1. 

Turn 

ON

 the main gas supply and check all fittings and connections for leaks with soap and water solution.

2. 

Move the OFF/REMOTE slide switch on the front of Switch Box to the REMOTE position (See figure 15).

3. 

Push the ON button on the remote transmitter this will start the ignition system. The pilot will begin to spark and

 

then light. Once the pilot is lit for 2 seconds the main burner will light.

4. 

Adjust the main flame from HI to LO with the manual HI/LO knob on front of valve kit.

NOTE

: To manually start the valve kit, move the OFF/REMOTE slide switch on the front of the Switch Box to the OFF 

position then push the rocker switch to the “I” position this will light the main burner. Once the pilot is lit for 2 seconds the 

main burner will light.

 

After the installation is complete follow these steps to operate the AFVK-SP-H/L-SPLIT or AFVK-SP-MH/L-SPLIT

1. 

Turn 

ON

 the main gas supply and check all fittings and connections for leaks with soap and water solution.

2. 

Move the OFF/REMOTE slide switch on the front of Switch Box to the REMOTE position (See figure 15).

3. 

Push the ON button on the remote transmitter position this will start the ignition system. The pilot will begin to 

 

spark and then light once the pilot is lit 2 for seconds later the main burner will light.

4. 

Adjust the main flame from HI to LO with the HI/LO buttons on the remote transmitter.

NOTE

: To manually start the valve kit, move the OFF/REMOTE slide switch on the front of the Switch Box to the OFF 

position then push the rocker switch to the “I” position this will light the main burner. Once the pilot is lit 2 seconds the main 

burner will light.

NOTE

: On the AFVK-SP-H/L press and release the LO button and the flame will switch to LO. Press and release the HI 

button and the flame will switch to HI.

 

NOTE

: On the AFVK-SP-MH/L press and hold the LO button and the flame will modulate to LO. Press and hold the HI 

button and the flame will modulate to HI.  

 

IMPORTANT NOTE

: On initial start up: due to air in the gas supply line it may take an extended amount of time for the 

pilot to light. There is a 60 second lockout built into the module. To reset, turn the rocker switch OFF, then ON, or push the 

OFF button on the remote transmitter, then push the ON button.

TROUBLESHOOTING

CAUTION

: An experienced qualified service technician should only perform troubleshooting procedures.

If the pilot will not stay lit:

1. 

Confirm that the “S” sensor wire and the “I” igniter wires are properly connected to the module “S” and “I” terminals

 

on the module (See figure 6 for terminal locations).

2. 

Confirm that the Spark to Pilot burner is properly grounded to the gas control valve (Ground is provided through 

 

the pilot tubing).

3. 

Check the ground wire from the module to the gas control valve (Black ground wire on the 8 pin conector)

4. 

Check the power source battery pack connections and voltage of batteries.

5. 

Optional check the position of the CONTINUOUS PILOT switch on the Switch Box (See figure 16). 

If main burner does not come ON when the manual rocker switch or remote control is turned ON:

1. 

Confirm that the pilot sparks and lights.

2. 

Check the (2) pin plastic connectors that plug in the face of the gas control valve (See figure 5).

3. 

Confirm that the gas control valve is properly grounded to the valve kit module.

If remote won’t operate Valve 

1.    

Ensure the module switch is in Remote position and check batteries in the remote and the battery pack.

2.    

Clear Codes: Memory in the module might be full if the learn button is pressed too many times. If this happens no

 

audible beep will be heard.  To clear memory, place the module slide switch into the REMOTE position.  Press 

 

the learn button and release after 10 seconds.  You should hear three (3) long audible beeps indicating all codes

 

have cleared.  You can now “relearn” the transmitter to the module as described below.

3.  

Press the LEARN button on the module to accept the transmitter security code.  Ensure the slide button on the

 

module in the REMOTE position; the module will not LEARN if the slide switch is in the OFF position.  The LEARN

 

button is located on the side of the module (See figure 17).  Using the pen or toothpick gently press and release 

 

the black LEARN button inside the hole.  When you release the LEARN button the module will emit an audible

 

 “beep”.  After the module emits a beep press the transmitter ON button and release.  The module will emit several

 

beeps indicating that the transmitter’s code has been accepted into the module then you can presume normal

 

operation.

American Flame AFVK-SPLIT VALVE KITS 

REV 12-27-13  Page 8 of 9

Содержание AFVK-SP-H/L-SPLIT

Страница 1: ...for additional information consult a qualified installer service agency or gas supplier FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light the appliance Do not touch any electrical switc...

Страница 2: ...ottom of the pilot bracket is resting against the pan This will hold the pilot at the 45 position Use caution when bending pilot tubing not to kink the tubing and when locating the igniter and flame s...

Страница 3: ...nlet Flex Line Fig 2 Basic installation layout centering the grate and components inside the firebox NOTE This diagram is strictly showing general layout and not to be used for clear ance purposes Ame...

Страница 4: ...tor Blue White Wires Pilot Ass y Fig 5 Gas Valve Identification Fig 6 Module Identification American Flame AFVK SPLIT VALVE KITS REV 12 27 13 Page 4 of 9 5 Bend inlet gas supply line and connect the 3...

Страница 5: ...1 NOTE On the AFVK SP SPLIT the battery pack switch can be placed in either position because the red and black wires are removed and not required for this system Because this kit has a manual flame he...

Страница 6: ...er will now point to LP and the shaft will stay recessed inward 4 To convert the valve back to the factory setting NAT push in the rotary knob and rotate back to NAT NOTE the marker will now point to...

Страница 7: ...See figure 18 Press and release the learn button with a pen There will be a beep sound from the module Then press any key on the remote transmitter Once the modules internal receiver accepts the tran...

Страница 8: ...set turn the rocker switch OFF then ON or push the OFF button on the remote transmitter then push the ON button TROUBLESHOOTING CAUTION An experienced qualified service technician should only perform...

Страница 9: ...er Allows system to operate without batteries OPTIONAL ACCESSORIES American Flame AFVK SPLIT VALVE KITS REV 12 27 13 Page 9 of 9 Limited Warranty American Flame warrants the AFVK SP SPLIT VALVE KIT SY...