American Fibertek MTX-8229C Скачать руководство пользователя страница 3

 

3

INSTALLATION AND OPERATION INSTRUCTIONS 

 

INTRODUCTION 

 

Thank you for purchasing your American Fibertek Series 8229C multimode two channel video 
multiplexer with return AD/Bosch Manchester control and bi-directional contact closure. Please 
take a few minutes to read these installation instructions in order to obtain the maximum 
performance from this product. 
 

FUNCTIONAL DESCRIPTION 

The 8229C Series units operate as a transmitter / receiver pair for the transmission of two 
simultaneous, real time baseband NTSC / PAL video signals with return Manchester control and 
contact closure over one multimode fiber optic cable.  
 
The MTX-8229C transmitter accepts up to two video inputs and multiplexes these signals along 
with the data signals onto a single optical output port for connection to the fiber transmission 
system. Correspondingly, the MRX-8229C receiver converts the optical signal to two 
independent video output signals along with the data signals. 
 
This link can accommodate both a return Manchester data interface and a bi-directional contact 
closure interface. These interfaces function independent of each other and can be used 
individually or concurrently. 
 
The 8229C Series units operate on 50 um or 62.5 um multimode fiber. Refer to the data sheets 
for detailed performance specifications. 
 
The individual units may be configured for rack mounting or wall mounting depending upon the 
position of the included mounting hardware. 

 
INSTALLATION 

THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND 
SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL 
CODES. 
 
To install the MTX-8229C or MRX-8229C it is first necessary to mount the rack flanges to the 
unit. 
 
For rack mounting the ears are installed on the 
sides of the unit with the surfaces that have 
oval holes flush with the front of the unit as in 
Figure 1. Mount the ears with the #10 flathead 
screws provided. To mount in the rack cabinet, 
use mounting screws that are appropriate for 
the rack cabinet being used. 
 

Содержание MTX-8229C

Страница 1: ... Copyright 2005 American Fibertek Inc 1228JD Instruction Manual MTX 8229C MRX 8229C Two Channel Video Multiplexer with Return AD Bosch Manchester Code and Bi directional Contact Closure ...

Страница 2: ...llation 3 Power Source 4 Power Connection 4 Fiber Connection 4 Video Input Output Connections 4 Data Configuration 4 Data Connections and Terminations 5 MTX 8229C Status LED Indicators 6 MRX 8229C Status LED Indicators 7 Warranty Service Information 8 ...

Страница 3: ...ndent video output signals along with the data signals This link can accommodate both a return Manchester data interface and a bi directional contact closure interface These interfaces function independent of each other and can be used individually or concurrently The 8229C Series units operate on 50 um or 62 5 um multimode fiber Refer to the data sheets for detailed performance specifications The...

Страница 4: ...f the unit Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used VIDEO INPUT OUTPUT CONNECTIONS Video input and output connections are located on the rear of the unit A BNC connector is provided for each channel Please note that video channels one two and five through eight are not used in this unit The video inputs are connected to an appropriate 75Ω baseba...

Страница 5: ...ifies the specific connections for the Manchester and RS232 data connections for the MRX 8229C MRX 8229C DATA TERMINATION REQUIREMENTS Manchester Data Signals The Manchester data input on the MRX 8229C is internally terminated with 120 ohms It is recommended to provide a 120 ohm termination at the copper device which is terminating the MTX 8229C data output signal If the MTX 8229C data output sign...

Страница 6: ... 2 TX DATA 2 RX Not Used Manchester Rx Contact State Contact State OLI A bi color LED indicator monitors the optical input power of the data signal that is being received at the MTX 8229C from the MRX 8229C AC power and optical input status associated with this LED are summarized below Optical Level Indicator AC Power Status Optical Status Green On Proper Optical Input Power Present Red On Optical...

Страница 7: ...open and on to indicate contact closed The data activity associated with these front panel DATA LEDs are summarized below DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX Manchester Tx Not Used Contact State Contact State OLI 1 A bi color LED indicator monitors the power of the optical input signal that is being received at the MRX 8229C from video channels three and four of the MTX 8229C AC power and opti...

Страница 8: ...R THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In any event American Fibertek will not be responsible or liable for contingent consequential or incidental damages No agreement or understanding expressed or implied except as set forth in this warranty...

Отзывы: