American Fibertek MTX-81B Скачать руководство пользователя страница 4

 

4

RESET PUSH BUTTON 

A recessed momentary contact push button is located on the left side of the chassis near the LED 
indicators. Pushing this button resets the four contact outputs of the MTX-81B to their default states 
and sends a signal to the MRX-81B or RRX-81B to reset all its outputs to their default states. 

 

LATCHING SELECT SWITCH 

A latching select switch is located on the left side of the chassis near the LED indicators. When switch 
#1 is set to the up (off) position, all contact output states remain unchanged during a loss of optical 
connection or DC power to the MTX-81B. Contact outputs will remain unchanged until DC power is 
restored to the MTX-81B and a valid data stream is received from the MRX-81B or RRX-81B or the 
reset button is depressed. When switch #1 is set to the down (on) position, all contact output states will 
revert to their default states during a loss of optical connection or DC power to the MTX-81B. 

 

MTX-81B STATUS INDICATORS 

The MTX-81B provides the following LED status indicators to aid in installation and troubleshooting: 

 

CC1 THROUGH CC8 

A green LED indicator is provided for each of the contact closure inputs and outputs of the MTX-81B. 
Contact closure status associated with these LED’s is summarized below. 

 

Contact Closure LED 

Contact Closure Input /Output Status 

Green 

Contact Terminals Closed (Shorted) 

Off 

Contact Terminals Open 

 

OLI/DC PWR 

A bicolor LED indicator monitors the power of the optical signal that is being received at the MTX-81B 
from the MRX-81B or RRX-81B. DC power and optical input status associated with this LED are 
summarized below. 

  

Optical Level Indicator 

DC Power Status 

Optical Status 

Green 

On  

Proper Optical Input Power Present 

Red 

On 

Optical Input Not Detected 

Off 

Off 

Check Power Supply 

 

LIFETIME WARRANTY INFORMATION 

American Fibertek, Inc warrants that at the time of delivery the products delivered will be free of defects 
in materials and workmanship. Defective products will be repaired or replaced at the exclusive option of 
American Fibertek. A Return Material Authorization (RMA) number is required to send the products 
back in case of return. All returns must be shipped prepaid. This warranty is void if the products have 
been tampered with. This warranty shall be construed in accordance with New Jersey law and the 
courts of New Jersey shall have exclusive jurisdiction over this contract. 

EXCEPT FOR THE 

FOREGOING WARRANTY, THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR 
A PARTICULAR PURPOSE OR OTHERWISE, EXPRESSED OR IMPLIED, WHICH EXTENDS 
BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT.

 In any event, American Fibertek will 

not be responsible or liable for contingent, consequential, or incidental damages. No agreement or 
understanding, expressed or implied, except as set forth in this warranty, will be binding upon American 
Fibertek unless in writing, signed by a duly authorized officer of American Fibertek. 

 

  

SERVICE INFORMATION 

There are no user serviceable parts inside the unit. 
In the event that service is required to this unit, please direct all inquiries to: 
American Fibertek, Inc. 

Phone: (877) 234-7200 

120 Belmont Drive 

Phone: (732) 302-0660 

Somerset, NJ  08873 

FAX (732) 302-0667 

E-mail: 

[email protected]

 