VIEW MANAGER 96 ENHANCED TOUCH TRACKER
8000-0748-02, REV. B1
INSTALLATION INSTRUCTIONS
4 of 6
Figure 8: Installing multiple Touch Trackers.
J3
J2
2 1
3
4
5
P1
1
2
3
4
J3
J2
2 1
3
4
5
4. Plug the EIM power supply or transformer into
a grounded, 3-wire electrical outlet.
Note
: If the keypad and backlighting do not
light when power is applied, repeat steps 3
and 4. Disconnect the controllers from the
EIMs after completing this test. They will be
connected later, one at a time.
Continue with Configuring
Use with VM96 to set up the Enhanced Touch
Trackers.
Configuring Touch Trackers
for Use with VM96
Note
: Touch Trackers shipped from the factory are
configured to work with VM96 version 4.x and
later. If your VM96 software version is 3.x, the
Touch Tracker mode will need to be set.
Connecting Touch Trackers
IMPORTANT:
Touch Trackers must be connected
one at a time
1. Start the VM96 console.
2. Determine the VM96 software version.
a. Start the Administrator menu.
b. Select “
Setup
” then “
System
”.
The Setup System form appears on the
screen.
c. Check the version number. The version
number appears in the upper right corner of
the form.
d. Do one of the following:
•
If the VM96 software version is 3.x
, the
Touch Tracker must be set to version 3
mode. See the note before step 3 for
instructions. Press
Alt+X
, then
Enter
to
exit the form.
•
If the VM96 software version is 4.x or
later
, the Touch Tracker is ready to use.
Press
Alt+X
, then
Enter
to exit the form.
e. Press
Alt+X
, then
Enter
to exit the
Administrator Menu. Continue with step 3.
Note:
If the VM96 software is version 3.x, you
must press and hold number
3
while
performing the next step
3. Attach the cable to the Touch Tracker.
After going through its startup sequence, the
Touch Tracker displays the following LCD
message:
Sensormatic
Touch Tracker v5
After a few moments, the LCD displays:
Cam A1
Mon __
T
OUCH
T
RACKER
#2
Power
Supply
SensorNet
Link
VM96 card,
J-Box link,
or other
SensorNet
device
SensorNet A
SensorNet B
24Vac A
Ground
24Vac B
RJ-45 Cable
EIM #2
Strain Relief
EIM #1
Power
Supply
T
OUCH
T
RACKER
#1
RJ-45 Cable
Strain Relief
24Vac A
Ground
24Vac B
SensorNet A
SensorNet B
Terminated
Unterminated