50/60HZ J-BOX 

8000-0320-01, REV. E 

INSTALLATION GUIDE 

2 of 2

 

C.   Connect the 4-Conductor Data Cable 

1.  Route a 4-conductor cable into the J-box, strip 

four wires to expose 1cm (3/8in) of wire, and 
cut the drain wire back to the outer sheath. 

2.  Insert wires in holes in the spring-loaded 

terminal block by pushing the orange buttons 
beside the holes. Note the function label on the 
PC board beside each button. 

 

D.   Connect Power to J-Box 

CAUTION:

 The J-Box must connect to a branch 

circuit controlled by a disconnect device, such as a 
circuit breaker, with at least a 3mm disconnect 
separation. Recommended capacity of the 
disconnect device branch circuit is 10A, and the 
device must be readily accessible. If these 
conditions cannot be met, install a disconnect 
device (with at least 3mm separation) in series with 
the J-Box, and between the branch and the J-Box.

 

If using conduit 

1.  Remove the cover over terminal block TB3. 
2.  Route 50 or 60Hz electrical power into the J-

box through the small knockout and connect it 
to TB3 (see table opposite). 

Note:

 Steps 3–5 for RJ860AP1 only. Otherwise, 

skip to step 6. 
3.  An 18cm (7in) ground wire from TB3 is attached 

to a grounding post on the enclosure. Remove 
the washer and nut from the grounding post 
and remove the ground wire terminal.  

4.  Wrap the branch circuit ground wire completely 

around the grounding post and secure using the 
washer and nut. 

5.  Reattach the TB3 ground wire terminal to the 

grounding post and secure using the extra 
washer and nut supplied. 

6.  Reattach the cover over TB3. 

If using line cord 

CAUTION:

 Use only polarized plug/cord sets; non-

polarized plugs invalidate regulatory approvals!  

Cord type:

  

North America: The cord must be type SJT, with 
minimum conductor size of 18AWG and fitted with a 
connector rated at 10A, 125V. The cord anchor 
accepts cords with a 5–9mm outer diameter. 
EU: The cord must be type H05 VV-F or H05 VV 
H2-F, with minimum conductor size of .75mm2 and 
fitted with a connector rated at 10A. The cord 
anchor accepts cords with a 5–9mm outer diameter. 

1.  Remove the cover over terminal block TB3. 
2.  Place the anchor for the power cord in the 

knockout and pass the power cord through the 
anchor. 

3.  Remove the outer sheath from the power cord 

and cut the three wires inside to length with the 
ground wire being the longest so it will break 
last if the anchor fails. 

4.  Connect the line and neutral leads to TB3 (see 

table below). Tie wrap these leads close to 
TB3. 

RJ860AP1 only.

 An 18cm (7in) ground wire 

from TB3 is attached to a grounding post on the 
enclosure. Remove the washer and nut from 
the grounding post and remove the ground wire 
from the post.  

RJ860AP and RJ860AP2 only.

 Install a ring 

terminal on the power cord’s ground wire. Place 
this terminal over the grounding post and 
secure using the washer and nut. 

RJ860AP1 only.

 Reattach the TB3 ground wire 

terminal to the grounding post and secure using 
the extra washer and nut supplied. 

5.  Tighten the anchor to secure the power cord. 
6.  Reattach the cover over TB3. 
 

 

60Hz Line Cord 

60Hz Conduit 

TB3-1 Hot 

(Brown) 

Hot 

TB3-2 Neutral 

(Blue) 

Neutral 

Ground Lug 

Ground (Green) 

Ground 

 

 

50Hz Line Cord 

50Hz Conduit 

TB3-1 

L (Hot) 

L (Hot) 

TB3-2 

N (Neutral) 

N (Neutral) 

Ground Lug 

Ground 
(Green/Yellow or 
Copper) 

Ground 

 