American Dynamics RJ855AP Скачать руководство пользователя страница 3

SENSORNET 6-POSITION JUNCTION BOX  
8000-0975-01, Rev. F 

 INSTALLATION 

GUIDE 

3

 

 

Power and Data Connections and 
Terminations 

IMPORTANT:

 See top of Page 1 for restrictions on 

the number of outdoor domes connected to P1–P6. 

1.  Strip the three power and two data leads from 

the composite cable and attach them to a 
5-position compression connector, following the 
P1–P6 Connector table from Figure 4. 

2.  Plug the compression connector into an 

available port (P1–P6) on the PCB. 

3.  Wire the SensorNet data cable coming from the 

host device (and any cables going to an 
auxiliary J-Box or other SensorNet device) to a 
4-position compression connector, following the 
P8 Connector table from Figure 4. 

4.  Plug the compression connector into port P8 on 

the PCB. 

5.  Set jumpers JW1, JW2, JW3, and JW4 on the 

PCB (see Figure 4) to the correct position. 
Shorting pins 1–2 terminates the device. Refer 
to the SensorNet Network Guide to determine 
the necessary terminations for the chosen 
network topology. 

 

Figure 4.  PCB Connectors and Jumpers 

F 1

F 2

F 4

F 3

P1

P2

P3

P4

P5

P6

HOST   

AUX

+ 5 V D C

A C   P

W

R

F A L S E

C D

1 2 3

4 5 6

A U X

H O S T

P7

P1

P2

P3

P4

P5

P6

HOST  AUX

+5VDC AC PWR

FALSE

CD

123

456

AUX

HOST

P7

P8

3  2  1

3  2  1

3  2   1

3  2   1

HOST

JW3

DOME 456

JW2

DOME 123

JW1

AUX

JW4

3  2  1

3  2  1

3  2  1

3  2  1

HOST

JW3

DOME 456

JW2

DOME 123

JW1

AUX

JW4

 

Data and Power LED Indicators 

The LED indicators on the PCB (see Figure 5) 
allow visual verification of SensorNet signals and 
power to the dome port and host/auxiliary ports. 
They illuminate to indicate the following conditions: 

• 

AC PWR

 is yellow when 24Vac from the 

transformer to the PCB is present. 

• 

+5VDC

 is green when DC power from the on-

board regulator is present. 

• 

FALSE CD

 is red for 0.5 sec if the device 

receives a false pulse (indicating noise on the 
SensorNet cable). 

• 

123

 is yellow for 30ms to indicate 

communications activity from dome ports 1, 2, 
or 3. 

• 

456

 is yellow for 30ms to indicate 

communications activity from dome ports 4, 5, 
or 6. 

• 

AUX

 is yellow for 30ms to indicate 

communications activity from the auxiliary port. 

• 

HOST

 is yellow for 30ms to indicate 

communications activity from the host port. 

 

Figure 5.  On-Board LEDs 

+5VDC AC PWR

FALSE
CD

123

456

AUX

HOST

 

 

P1–P6 Connectors 

Color Pin 

Function 

Orange 1  SensorNet 

White 2 

28Vac 

Red 3 

Ground 

Black 4 

28Vac 

Yellow 5 SensorNet 

– 

 

P8 SensorNet Connector 

Color Pin 

Function 

Orange 1  Host 

Yellow 2 Host 

– 

Orange 3  Auxiliary 

Yellow 4 Auxiliary 

– 

PCB Power 

Domes

4–6

Domes
1–3 

Host and Aux J-Box Data 

Содержание RJ855AP

Страница 1: ...ding vibration The installation must satisfy the following requirements Follow the SensorNet Network Guide section to ensure proper network design Minimize exposure to environmental extremes by mounting the J Box and the SpeedDome in a sheltered area when possible Always use dedicated unswitched 24 hour AC power supplied in accordance with local codes and with proper grounding Ensure that the J Bo...

Страница 2: ...the chassis panel for details 1 Remove cover plate and chassis Figure 1 to access connector TB2 at rear of enclosure 2 Connect incoming AC wires to the TB2 connector for 115Vac or 230Vac operation using Figure 2 and its associated tables Figure 2 TB2 Power Connections N L Connecting Power to the PC Board 1 Replace the four screws that secure the chassis in the enclosure 2 Connect AC power to the p...

Страница 3: ...ST AUX 5VDC AC PWR FALSE CD 123 456 AUX HOST P7 P8 3 2 1 3 2 1 3 2 1 3 2 1 HOST JW3 DOME 456 JW2 DOME 123 JW1 AUX JW4 3 2 1 3 2 1 3 2 1 3 2 1 HOST JW3 DOME 456 JW2 DOME 123 JW1 AUX JW4 Data and Power LED Indicators The LED indicators on the PCB see Figure 5 allow visual verification of SensorNet signals and power to the dome port and host auxiliary ports They illuminate to indicate the following c...

Страница 4: ...a need for service or support Our dealers are fully empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied...