![American Dynamics RHODUL-03E Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/american-dynamics/rhodul-03e/rhodul-03e_installation-manual_2923591003.webp)
SPEEDDOME ULTRA OUTDOOR HOUSING
8200-0184-10, REV. C
CONTINUATION OF INSTALLATION GUIDE
3 of 12
SpeedDome
®
Ultra
Outdoor Housing
Installation Guide - Continued
RHODUL-03E/-03VRE (Clear Bubble)
RHODUL-04E/-04VRE (Smoked Bubble)
Contents:
To the Installer....................................................... 3
About the Product.................................................. 3
Parts Supplied ....................................................... 3
Tools Required ...................................................... 3
Warnings and Cautions......................................... 4
Preventing Condensation...................................... 5
Parts List for Authorized Users ............................. 5
Connector Pin Assignments.................................. 6
Cable Requirements.............................................. 6
Manual Heater Operation...................................... 7
Housing Termination ............................................. 8
Troubleshooting..................................................... 9
Specifications ...................................................... 11
Declarations ........................................................ 12
© 2005 Sensormatic Electronics Corp.
To the Installer
This guide assumes that the outdoor mounting
structure to which the housing is attached is in
place and that data and power cables have been
pulled to the installation site. To install the outdoor
mounting structure, see documents shipped with
the structure.
About the Product
The outdoor housing has a sunshield cover and
bubble that protect the SpeedDome Ultra dome
camera. Tamperproof screws affix the bubble to
the housing.
The housing is temperature controlled and
weatherproof. A built-in thermostat and heater
prevent ice from forming on the outside of the
bubble.
The standard version has one alarm input and one
SPDT relay. The vandal-resistant version adds
three more alarm inputs. Surge protection is
provided on all external lines, including video.
Parts Supplied
•
Housing assembly 0100-2468-02
•
Bubble assembly 0404-0083-01/-02
•
Tamperproof
drive
1400-0149-01
•
Install kit 0351-2183-04
Purchase or Supply Separately
Male BNC connector
Tools Required
•
6.6mm (1/4in) fixed-handle
nut driver for Torx bit
•
Wire cutters and strippers
•
2.5mm (0.1in) slotted screwdriver