10. Set the dome address (Figure 19).
Figure 19. Setting address switches
0
9 0
9 0
9
MSB
LSB
SW3
SW1
SW2
Use the following addresses for the protocols
shown:
PROTOCOL
SW3
SW2
SW1
AD Manchester
,
Range: 001—064
0
x
x
PELCO "P,"
4800 baud
RS-422, Range: 001—099
0
x
x
Sensormatic
, 4800 baud
RS-422, Range: 001—063,
065—099
0
x
x
Sensormatic,
RS-422
Address 64 is used for global
broadcasts
0
6
4
SensorNet
,
Range: 001—099
0
x
x
VICON
, 4800 baud RS-422,
Range: 001—099
0
x
x
1
x
x
SensorNet
,
Range: 100—254
2 x x
Address 255 is used for
global broadcasts
2
5
5
Dept. of Transportation
(NTCIP)
, 4800 baud RS-422,
Range: 301—399
3
x
x
Dept. of Transportation
(NTCIP)
, 9600 baud RS-422,
Range: 401—499
4
x
x
Dept. of Transportation
(NTCIP)
, 19.2K baud RS-422,
Range: 501—599
5
x
x
PROTOCOL
SW3
SW2
SW1
PELCO "P,"
2400 baud
RS-422, Range: 601—699
6
x
x
PELCO "P,"
9600 baud
RS-422, Range: 701—799
7
x
x
Reset
HITACHI
VK-xxxx(E)R
camera block from 38.4K to
4800 baud (SpeedDome Ultra
VII WITH EIS 0100+ feature
only).
8
3
0
PANASONIC
UTC
8
9
0
Tyco
UTC
8
9
1
PELCO
UTC (Origins,
Standard, & Extended)
8
9
3
RS-422, LED diagnostic
mode for dome wiring
installations without the I/O
Board
9
0
0
Manufacturing Use
,
Range: 901—999
9
x
x
11. Connect the housing and eyeball assembly to
a. Align the Cap and Base tabs, then turn
clockwise until you hear a click.
12. Wait a few seconds for dome to begin its
homing routine. The homing routine indicates
that the address was placed into the dome
memory and that the dome is ready for
programming.
Figure 20. Connecting housing and eyeball
assembly to base
Note: Align tabs
on Cap and
Base.
Turn clockwise