American Dynamics RAS918LS Скачать руководство пользователя страница 1

SPEEDDOME ULTRA VII EIS DAY/NIGHT CAMERA DOME 

8200-0184-14, REV. A 

INSTALLATION AND SERVICE GUIDE 

1 of 37 

SpeedDome

®

 Ultra VII EIS 

Day/Night Camera Dome 

Installation and Service Guide 

Figure 1. SpeedDome Ultra VII EIS Day/Night 

Camera Dome 

 

Camera Dome Product Codes 

Product Description 

RAS918LS 

DAY/NIGHT, EIS, 60HZ, 23X, NO BASE, 
BLACK 

RAS918LSP 

DAY/NIGHT, EIS, 60HZ, 23X, STD BASE, 
BLACK (RUPTB) 

RAS918LSI DAY/NIGHT, 

EIS, 60HZ, 23X, I/O BASE, 

BLACK (RUIOB) 

 

 

 

 

 

 

 

 

 

 

 

 

© 2005 Sensormatic Electronics Corp. 

Contents 

About this Guide ....................................................1

 

About the Camera Dome .......................................2

 

Cable Requirements ..............................................7

 

Install/Removal Tool for Base with I/O Board........8

 

Power-Up Routine..................................................9

 

Synchronizing Domes ............................................9

 

Diagnostic LEDs ....................................................9

 

Warnings and Cautions .........................................9

 

Indoor Installation.................................................11

 

Using the Install/Removal Tool ............................20

 

Troubleshooting Indoor Domes ...........................22

 

Parts List for Authorized Users ............................32

 

Specifications-Indoor Dome.................................34

 

Specifications-23X Camera with EIS ...................35

 

Declarations .........................................................36

 

Appendix A: Vicon Wiring Configurations ............37

 

 

About this Guide 

This guide explains how to connect the camera 
dome to a mounting base and how to service it. 

It does not explain how to: 

  Determine a mounting location for the camera 

dome. The mounting location is determined by 
customer requirements; therefore, this 
information is provided separately. 

  Attach the mounting base. There are two types 

of mounting bases. See information shipped 
with the base. 

  Assemble housings and structures used with 

this camera dome. See information shipped with 
the housing and structure. 

  Program the camera dome. See operator's 

guide shipped with the dome. 

 

Mounting 
Base 

Housing 

Eyeball 

Содержание RAS918LS

Страница 1: ...tions 9 Indoor Installation 11 Using the Install Removal Tool 20 Troubleshooting Indoor Domes 22 Parts List for Authorized Users 32 Specifications Indoor Dome 34 Specifications 23X Camera with EIS 35 Declarations 36 Appendix A Vicon Wiring Configurations 37 About this Guide This guide explains how to connect the camera dome to a mounting base and how to service it It does not explain how to Determ...

Страница 2: ... base A lanyard connects between the base and the housing and eyeball assembly to prevent cables from being pulled during disassembly Base with I O Board With this base video data and power cables are pre connected to an I O PC board A spring finger connector on the board makes electrical contact with the housing and eyeball assembly as it connects to the base Housing and Eyeball Assembly The hous...

Страница 3: ...Electrical Box in Ceiling RHIU3X3 3 X 3 mounting plate Attaches dome to a standard 3 5 x 3 5 duplex electrical box CAUTION Do not use the same electrical box used for line voltage mains RHIU4X4 4 X 4 mounting plate Attaches dome to a standard 4 x 4 duplex electrical box CAUTION Do not use the same electrical box used for line voltage mains Option in white but can be painted to match decor Top hat ...

Страница 4: ...unting structures optional RHIUFB RHIUAB RHIUHC RHIU2X2 RHIUTH RHIUTR RUCLR RUSLV RUSMK RUGLD RHIULWM RHIUCM RHIUWM RHIU3X3 RHIU4X4 RHIUPNDT RHIUIBM RHIU2X2P ADSDUPIHC ADSDUPIHS ADSDUPIVRC ADSDUPIVRS ADSDUPIHC ADSDUPIHS ADSDUPIVRC ADSDUPIVRS Vandal Resistant Bubble Vandal Resistant Bubble RD500A RD500A RHIUTH RHIUTH RHIUTH ...

Страница 5: ... RHOWCA Corner Bracket The outdoor housing contains a pre installed mounting base a cooling fan for hot weather a heater for cool weather and to prevent icing and surge protection circuitry An environmental PC board is used to pre wire cables A round spring finger connector on the board makes electrical contact with the housing and eyeball assembly as it connects to the base Note Do not use the I ...

Страница 6: ...ructures optional Note Housing is shown for reference only RHOTR over roof mount comes with the ROENDC end cap shown with RHOTRF bracket RHOPN pendant mount ROENDC end cap RHOWPA pole mount comes with the ROENDC end cap RHOSW RHOLW wall mount comes with the ROENDC end cap RHOWCA corner bracket only shown with RHOLW mount RHOSW RHOLW ...

Страница 7: ... 3361 Power Cable For the camera dome to operate properly line voltage must not go below the worst case low line voltage shown in the following table Make cable lengths as short as possible to minimize affects of low line voltages As shown in the table maximum cable length depends on the Class 2 LPS low voltage ac source such as a J box and the worst case low line voltage These lengths are for Sen...

Страница 8: ...cable Figure 9 shows twisted pair cable connections See installation guide 8200 0298 01 for details Figure 9 Cabling overview Install Removal Tool for Base with I O Board The install removal tool Figure 10 enables you to connect or disconnect the housing and eyeball assembly from the base with I O board and to attach detach skirts and bubbles to a top hat housing without the need for a ladder The ...

Страница 9: ...nable you to check for power and data If an RS 422 network is used other LEDs on the board indicate that wiring is correct reversed open or grounded Warnings and Cautions Please review the following warnings and cautions before you begin installation or service WARNINGS WARNING ALWAYS USE Proper safety equipment for the location and type of installation Proper lift equipment to reach the installat...

Страница 10: ...d power cables adjacent to or in the same conduit as line voltage mains power SensorNet 485 networks require 22 AWG unshielded cable Do not exceed 32 devices per cable run RS 422 networks require 22 AWG shielded cable Do not exceed 10 devices per cable run Manchester networks require 18 AWG shielded cable Do not exceed 3 devices per cable run Always terminate the dome s CPU board JW1 if the camera...

Страница 11: ...local codes and ordinances Coordinate work with other trades to avoid interference Verify existing site conditions and coordinate with the owner s representative and appropriate utilities as required Obtain copies of all related plans specifications shop drawings and addenda to schedule and coordinate related work Thoroughly review the project to ensure that all work meets or exceeds the above req...

Страница 12: ...5 x x PELCO P 2400 baud RS 422 Range 601 699 6 x x PELCO P 9600 baud RS 422 Range 701 799 7 x x Reset HITACHI VK xxxx E R camera block from 38 4K to 4800 baud SpeedDome Ultra VII WITH EIS 0100 feature only 8 3 0 PANASONIC UTC 8 9 0 Tyco UTC 8 9 1 PELCO UTC Origins Standard Extended 8 9 3 RS 422 LED diagnostic mode for dome wiring installations without the I O Board 9 0 0 Manufacturing Use Range 90...

Страница 13: ...DO NOT connect the 9 pin plug unless you have performed step 3 first a Feed cables through the access hole in the base b Connect data and power wires to the 9 pin plug refer to charts below c Insert the plug into the mating receptacle in the top of housing and eyeball assembly Manchester data and power connections Order data cable 88760 plenum or 8760 non plenum from Belden by calling 1 800 235 33...

Страница 14: ...les for data and power 7 Connect the housing and eyeball assembly to the base Figure 15 by aligning the Cap and Base tabs and then turning clockwise until you hear a click Figure 15 Connecting housing and eyeball assembly to base cables and lanyard not shown 8 Apply power and wait a few seconds for the dome to begin its homing routine The homing routine indicates that address was placed into dome ...

Страница 15: ...s base To prevent damage to the dome hold the dome by its housing not its eyeball assembly 1 If the power LED CR33 on the I O board glows green then ac power is connected 2 Green CR2 red CR3 and yellow CR4 LEDs surround the video connection and are visible through opening Check that the following communication protocols are properly wired by observing these LEDs Figure 16 Cable connections Manches...

Страница 16: ...Rapidly Blinking No Wire to RX pin 6 not connected Mostly On Blinking Off Mostly On Blinking Off Rapidly Blinking No Wires to RX pin 6 and RX pin 7 reversed Off On Alternating Off and On Every 60 Sec No Wire to RX pin 7 not connected Wires to RX or RX not connected or shorted together Wires to RX and or RX shorted to ac ground 3 When not in address 900 test mode When done testing reset the address...

Страница 17: ...ou may need a small slotted screwdriver to gently pry jumper loose Be careful not to damage underlying PC board 2 Connect video cable or Twisted Pair Adapter to BNC connector P8 on I O board 3 Connect Manchester RS 422 or SensorNet 485 data wires to connector P1 If using a Pelco Coaxitron or Panasonic UTC protocol no data wires are connected just power Manchester data connections Order data cable ...

Страница 18: ...ect power to the base 9 Check LEDs on the I O board to verify power and data are reaching the dome Figure 18 a The green ac power LED glows steadily when ac power is applied b For Manchester or SensorNet The yellow comm LED glows steadily Manchester or blinks SensorNet If this LED is off then probably one or both communication wires are open or both are shorted together For RS 422 Press and hold d...

Страница 19: ...22 Range 401 499 4 x x Dept of Transportation NTCIP 19 2K baud RS 422 Range 501 599 5 x x PROTOCOL SW3 SW2 SW1 PELCO P 2400 baud RS 422 Range 601 699 6 x x PELCO P 9600 baud RS 422 Range 701 799 7 x x Reset HITACHI VK xxxx E R camera block from 38 4K to 4800 baud SpeedDome Ultra VII WITH EIS 0100 feature only 8 3 0 PANASONIC UTC 8 9 0 Tyco UTC 8 9 1 PELCO UTC Origins Standard Extended 8 9 3 RS 422...

Страница 20: ...code 08140 UPC 0 14746 58140 2 Procedure Referring to Figure 21 maneuver the stem of the tool into the top of the pole until it snaps in place TO ATTACH SKIRT OR BUBBLE Use the tool to push up on the bubble to secure it in place Magnets secure the bubble Lower the pole TO DETACH SKIRT OR BUBBLE Lifting the pole up at an angle use one of the hooks on the tool to catch one of the notches at the side...

Страница 21: ...ure 21 How to use the install removal tool Dome Connection reverse steps to disconnect Line up Line up Skirt or Bubble Attachment Detachment Do not use this tool to connect the base without I O board Attachment Detachment A B C B C D E Turn until you feel a click Catch notch and pull down Snap tool into pole ...

Страница 22: ...lade widths can damage connectors Socket wrench with 5in extension and 5 5mm 6mm 8mm and 10mm sockets 14 18 AWG and 20 22 AWG wire strippers Install Removal tool to connect disconnect dome to indoor bases with I O boards and to attach detach skirts and bubbles without a ladder Routine Troubleshooting Use this procedure if Dome does not respond to commands Dome does not produce video Quality of the...

Страница 23: ...g dome to another base with I O board Does dome display video or respond to commands YES Problem is likely cable connections or I O board if used Go to step 5 NO Contact your sales representative for repair instructions 5 Verify coaxial video cable is securely connected to coax of I O board Figure 22 Is cable disconnected YES Connect cable NO Go to step 6 Figure 22 I O board connector and jumper l...

Страница 24: ...ck comm line connections by pressing and holding data test switch SW1 Figure 23 and observing nearby red CR34 and green CR35 LEDs These LEDs indicate the following Constant green Blinking red Comm line correctly wired Constant green No red Data In shorted to ground Constant red Blinking green Data In wires reversed Blinking red Green off Data In shorted to ground Both LEDs off Data In wires shorte...

Страница 25: ... electrostatic sensitive PC boards Use a ground strap when handling boards Procedure 1 Match symptom to one of the following criteria Dome functions but does not pan Dome functions but does not tilt Dome does not home or respond to commands even when attached to another dome s base and its address switches are set correctly dead dome 2 Choose a b or c to determine if problem is a cable connection ...

Страница 26: ...Tools Required Phillips head screwdriver Small slotted screwdriver Removing the CPU Board CAUTION Electrostatic sensitive device Use a ground strap when handling CPU board Referring to Figure 24 1 Remove cap Remove three Phillips head screws holding cap then gently lift cap to one side 2 Detach connectors On CPU board detach 8 pin power supply cable from connector P1 pan motor cable from connector...

Страница 27: ...cts to connector CN3 on power supply board 4 Remove power supply board Remove three standoffs then remove power supply board from housing 5 Reverse steps to reassemble Figure 25 Removing the P S board Removing the Pan Motor Referring to Figure 26 1 Perform procedure Removing the CPU Board page 26 2 Perform procedure Removing the P S Board page 26 3 Remove pan motor Lift motor housing up as shown 1...

Страница 28: ...removed this cover can be easily removed Figure 27 Removing slot covers Removing the Camera 1 Perform procedure Removing the Slot Covers page28 2 Remove ribbon cable from camera Figure 28 Swivel camera yoke to expose camera connector Then using a small slotted screwdriver 1 gently pry camera connector loose from camera and 2 pull it down through cable tie wrap Figure 28 Removing the ribbon cable 2...

Страница 29: ...using a small slotted screwdriver to press the other b While pressing tabs push up on eyeball to detach it Figure 30 Loosening the eyeball 4 Detach slip ring connector Figure 31 Figure 31 Detaching the eyeball Removing the Camera Lens Board 1 Perform procedure Removing the Slot Covers page 28 2 Perform procedure Removing the Camera page 28 3 Perform procedure Detaching the Eyeball page 29 4 Separa...

Страница 30: ...amera lens board DO NOT unplug small white ribbon cable from connector J1 8 Push out on three prongs to detach camera lens board 9 Reverse steps to reassemble Figure 34 Removing the camera lens board Removing the Tilt Motor 1 Perform procedure Removing the Slot Covers page28 2 Perform procedure Removing the Camera page 28 3 Perform procedure Detaching the Eyeball page 29 4 Separate yoke brackets F...

Страница 31: ... new motor be careful to properly mesh motor and tilt gears Failure to do so can destroy both motor and tilt gear Verify tilt gear turns freely Updating Reprogramming Dome Software CAUTION This procedure involves extracting a flash memory chip an electrostatic sensitive device Use a ground strap when handling the chip To update or reprogram dome software 1 Insert the chip extractor tool into the s...

Страница 32: ...01 18 Fan Plate 0500 9850 02 19 Screw Thdcut M3 5 Qty 2 5899 0007 01 20 Standoff M3x6Hx19L Qty 3 5887 1122 020 21 Power Supply PC Board 5606 0015 03 22 Slip Ring Assy 2100 0005 01 23 Pan Motor 3501 0017 01 24 Housing 0500 7255 02 03 25 Bearing Assy Pan Gear 2510 0040 01 26 Skirt 0500 6710 02 Eyeball Assembly 27 Tilt Motor 3501 0018 01 28 Slot Cover No Lens 0500 8037 01 02 29 Yoke Camera 0500 7258 ...

Страница 33: ...K 04 B W 22X CCIR camera BLK 05 Color 22X NTSC camera WHT 06 Color 22X PAL camera WHT 11 Color 23X NTSC camera BLK 12 Color 23X PAL camera BLK 15 Color 23X NTSC camera WHT 29 Color 23X NTSC EIS camera BLK 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 20 21 22 23 24 25 26 Standard Base Assembly Base Assembly with I O Board Housing Assembly 0404 0078 03 04 19 RUPTB RUWPTB RUIOB RUWIOB Housing and Eye...

Страница 34: ... Data Storage 128 Kbytes of SRAM Menu Languages English French German Spanish Italian and Portuguese Electrical Input Voltage 18 30Vac 50 60 Hz NEC Class 2 LPS Design Tolerance 16 36Vac 50 60 Hz Power Consumption 16W max Current 0 85A max Allowable Drop Out 100ms Power On In Rush Current 1 5A Surge Protection Video Output Low capacitance Zener suppressor 6 5V 1500W Power Line TVS rated at 60V 1 5 ...

Страница 35: ...ith s open shutter 0 01 lux in IR mode 0 009 lux in IR mode with s open shutter White Balance Through the Lens TTL Automatic Tracing White balance ATW NTSC Effective Pixels 962 H x 654 V pixels Scanning 525 lines 60 fields 30 frames Horizontal 15 734kHz Vertical 59 9Hz Lens Design Type Aspherical Focal Length 3 6 to 82 8mm Aperture f1 6 wide angle f3 7 telephoto Viewing Angle equivalent to 8 80 mm...

Страница 36: ... empowered to provide the very best in customer service and support Dealers should contact American Dynamics at 800 507 6268 or 561 912 6259 or on the web at www americandynamics net WARRANTY DISCLAIMER Sensormatic Electronics Corporation makes no representation or warranty with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any p...

Страница 37: ...loop through wiring from Vicon dome In Vicon systems where domes support RS 485 daisy chaining daisy chain the SpeedDome Ultra VII domes off the controller or one of the Vicon domes in the communications chain Figure 41 SpeedDome Ultra VII dome RS 485 wiring from Vicon dome R R T T R R T T In Out In Out Command Response Vicon dome SpeedDome Ultra VII dome SpeedDome Ultra VII dome To controller or ...